Certificate No1798a to BS 7629-1:2015 (STANDARD 60) BS 6387:2013 (CWZ) EN 50200-2015 (Class PH120) EN 50200:2015 Annex E EN 60332-3-25:2009 BS 5839-1:2013 (Clause 26.2d Standard) EN 60332-3-24:2009
Read RedBook section introduction
Fire Resistant Cable
| Product | Nominal csa of conductor (mm2) | Core Construction (excluding drain wire and earth) | BS 7629-1 See note 3 | BS 6387 | EN 50200 | EN 50200 See note 4 | BS 5839-1 See note 5 | LPCB Ref. No. |
|---|---|---|---|---|---|---|---|---|
1.0(1) | 2 | STANDARD 60 | C, W, Z | PH120 | Annex E | Clause 26.2d | 1798a/01 |
See below for all products listed in this group.
Fire Resistant Cable
| Product | Nominal csa of conductor (mm2) | Core Construction (excluding drain wire and earth) | BS 7629-1 See note 3 | BS 6387 | EN 50200 | EN 50200 See note 4 | BS 5839-1 See note 5 | LPCB Ref. No. |
|---|---|---|---|---|---|---|---|---|
1.0(1) | 2 | STANDARD 60 | C, W, Z | PH120 | Annex E | Clause 26.2d | 1798a/01 | |
1.5(1) | 2, 3 & 4 | STANDARD 60 | C, W, Z | PH120 | Annex E | Clause 26.2d | 1798a/01 | |
2.5(1) | 2, 3 & 4 | STANDARD 60 | C, W, Z | PH120 | Annex E | Clause 26.2d | 1798a/01 | |
4.0(2) | 2, 3 & 4 | STANDARD 60 | C, W, Z | PH120 | Annex E | Clause 26.2d | 1798a/01 |
Uo/U 300/500V
Notes:
1. Solid conductor only.
2. Stranded conductor only.
3. In meeting the requirements of BS 7629-1:2015 Standard 60, the X-BURN PLATINUM cables listed met the requirements for smoke density of EN 61034-2, achieved less than 0.5%HCI for the outer covering, binder tape and insulation when tested in accordance with EN 60754-1 and in addition also met the fire resistance requirements of BS 6387:2013 Categories CWZ.
4. The duration of 30 minutes when tested in accordance with EN 50200:2015 Annex E is achieved by 15 minutes for the fire and mechanical shock phase and an additional 15 minutes for the fire, mechanical shock and water phase.
5. The X-BURN PLATINUM cables listed conform to BS 7629-1:2015, met Class PH120 when tested in accordance with EN 50200:2015 and met the 30 minutes duration when tested in accordance with EN 50200:2015 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2d of BS 5839-1:2013.
6. Where the cable diameter is greater than 12mm the cable is additionally approved to EN 60332-3-24.
7. Where the cable diameter is equal to or less than 12mm the cable is additionally approved to EN 60332-3-25.