Sector 36
Pace City - II
Gurgaon - 122 004
Haryana
India
Tel: +91 124 4752700
•
Fax: +91 124 4752750
Email: Arvind.Rathaur@Honeywell.com
Certificate No 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Certificate No 550e to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 & CEA 4021: 2003
Multi Criteria Detectors
Product | Description | LPCB Ref. No. |
---|---|---|
2351TEM | Conventional optical/thermal detector (B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 & B401DGSD bases) Note: Meets the requirements of EN54-5:2000 at Class A1R and EN54-7:2000 at low, medium & high sensitivity settings. |
550b/01 |
ECO1002 | Conventional photo-thermal detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases) Note: Meets the requirements of EN 54-5:2000 at class A1R at pre-set sensitivity. |
550b/02 |
FL/1002 | Conventional optical/thermal detector (FL/1000B base) Notes: Meets the requirements of EN54-5 at class A1R at pre-set sensitivity |
550b/02 |
22051TLE-xx-yy | Analogue addressable photo-thermal-IR multi-criteria detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 3) Certified at the following settings: - Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R |
550b/04 |
22051TE-xx-yy | Analogue addressable photo-thermal multi-criteria detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 3)Certified at the following settings: - Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R |
550b/05 |
22051TLEI-xx-yy | Analogue addressable photo-thermal-IR multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 3) Certified at the following settings: - Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R |
550e/01 |
22051TEI-xx-yy | Analogue addressable photo-thermal multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 3) Certified at the following settings: - Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R |
550e/02 |
2FA51T | Conventional photo-thermal class A1R detector (BFA1 base) Note: Meets the requirements of EN54-5: 2000 class A1R at pre-set sensitivity |
550b/06 |
Bases:
To read the Red Book section introduction click here.