Via Caboto 19/3
Trieste
34147
Italy
Tel: +44 (0)1444 230300
•
Fax: +44 (0)1444 230888
Email: sales@notifiersystems.co.uk
•
Web: www.notifierfiresystems.co.uk
Certificate No 154g to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Product | Description | LPCB Ref. No. |
---|---|---|
Pearl | Single loop analogue addressable control and indicating equipment
Incorporating the following units:
772489-NE CPU board Incorporating the following optional regional language text inserts: PRL-LED-EN-1 (English) PRL-D-1 (German) PRL-IB-1 (Iberia) PRL-BNL-1 (Benelux) PRL-LCD-NRD-1 (Swedish) PRL-MEA-1 (Middle East and Africa) PRL-IT-1 (Italian)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices
Notes:
1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. |
567au/20 |
ID3000 | Basic Equipment Kit, (BEK): Modular analogue addressable control and indicating equipment. 020-538 Basic Equipment Kit ID3000, Group 0 020-538-001 ID3000 Basic Equipment Kit, Group 1 020-538-003 ID3000 Basic Equipment Kit, Group 3 020-538-004 ID3000 Basic Equipment Kit, Group 4 020-538-005 ID3000 Basic Equipment Kit, Group 5
Incorporating the following as modular units:
Enclosures:
020-472-009 Backbox Kit Standard, Black / Grey
Modules:
020-559-001 Zone Extension Chassis Kit 1-64 Zone
Note 1: Products are available in language variants as follows:
Group 0: English and Icelandic, with English manuals Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. |
567au/04 |
ID3002 | Fixed build 2 loop analogue addressable control and indicating equipment. 002-473 ID3002, 2 Loop, PSU3A, Group 0, Red 002-474 ID3002, 2 Loop, PSU3A, Group 0 002-474-001 ID3002, 2 Loop, PSU3A, Group 1 002-474-003 ID3002, 2 Loop, PSU3A, Group 3 002-474-004 ID3002, 2 Loop, PSU3A, Group 4 002-474-005 ID3002, 2 Loop, PSU3A, Group 5
Incorporating the following as modular units:
Enclosures:
020-472-009 Backbox Kit Standard, Black / Grey
Modules:
020-559-001 Zone Extension Chassis Kit 1-64 Zone
Note 1: Products are available in language variants as follows:
Group 0: English and Icelandic, with English manuals Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. |
567au/04 |
ID3004 | Fixed build 4 loop analogue addressable control and indicating equipment. 020-727 ID3004, 4 Loop, PSU7A, Group 0, LIB 020-728 ID3004, 4 Loop, PSU7A, Group 0, ELIB 020-729 ID3004, 4 Loop, PSU7A, Group 0, LIB, printer 020-730 ID3004, 4 Loop, PSU7A, Group 0, LIB, 64 zone LED
Incorporating the following as modular units: Enclosures:
020-472-009 Backbox Kit Standard, Black / Grey
Modules:
020-559-001 Zone Extension Chassis Kit 1-64 Zone
Note 1: Products are available in language variants as follows:
Group 0: English and Icelandic, with English manuals Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. |
567au/04 |
ID3006 | Fixed build 6 loop analogue addressable control and indicating equipment. 020-731 ID3006, 6 Loop, PSU7A, Group 0, 2xLIB 020-732 ID3006, 6 Loop, PSU7A, Group 0, 2xELIB 020-733 ID3006, 6 Loop, PSU7A, Group 0, 2xLIB, printer 020-734 ID3006, 6 Loop, PSU7A, Group 0, 2xLIB, 64 zone LED
Incorporating the following as modular units:
Enclosures:
020-472-009 Backbox Kit Standard, Black / Grey
Modules:
020-559-001 Zone Extension Chassis Kit 1-64 Zone
Note 1: Products are available in language variants as follows:
Group 0: English and Icelandic, with English manuals Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. |
567au/04 |
ID3008 | Fixed build 8 loop analogue addressable control and indicating equipment. 020-735 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery Enclosure 020-736 ID3008, 8 Loop, PSU7A, Group 0, 3xELIB, 78Ah Battery Enclosure 020-737 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery Enclosure, Printer 020-738 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery enclosure, printer, 64 Zone LED
Incorporating the following as modular units:
Enclosures:
020-472-009 Backbox Kit Standard, Black / Grey
Modules:
020-559-001 Zone Extension Chassis Kit 1-64 Zone
Note 1: Products are available in language variants as follows:
Group 0: English and Icelandic, with English manuals Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. |
567au/04 |
002-467 | ID2net Network Gateway Unit, (NGU) Notifier Protocol
Incorporating the following as modular units: 020-643 ID2net Fibre Optic Interface Kit 020-647 ID2net Network Gateway Module, (NGM) for use in ID3000 Panels 020-648 PSU3A Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment type A 7.10.3 Output to fire protection equipment type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablements of addressable points 10 Test condition |
567au/05 |
ID50 | Single loop analogue addressable control and indicating equipment
002-455 ID50 Panel Group 0 002-455-001 ID50 Panel Group 1 002-455-003 ID50 Panel Group 3 002-455-004 ID50 Panel Group 4 May also incorporate the following optional modular unit: 002-553 RS485 Communication Kit
Certified with the following options with requirements:
7.8 Output to fire alarm devices
Note: Products are available in various language groups as follows:
Group 0: English, Icelandic, French, Italian, Portuguese and Spanish, |
567au/06 |
ID60 | Single loop analogue addressable control and indicating equipment
002-456 ID60 Panel Group 0 002-456-001 ID60 Panel Group 1 002-456-003 ID60 Panel Group 3 002-456-004 ID60 Panel Group 4 May also incorporate the following optional modular unit: 002-553 RS485 Communication Kit
Certified with the following options with requirements:
7.8 Output to fire alarm devices
Note: Products are available in various language groups as follows:
Group 0: English, Icelandic, French, Italian, Portuguese and Spanish, |
567au/07 |
ID61 | Single loop analogue addressable control and indicating equipment
002-463 ID61 Panel Group 0 002-463-001 ID61 Panel Group 1 002-463-004 ID61 Panel Group 4 002-485-001 ID61 Panel Group 1 (Red) Incorporating the following modular unit: 020-648 PSU3A Kit May also incorporate the following optional modular units: 020-479 RS485 Communication Kit 020-644-009 Printer Kit
Certified with the following options with requirements:
7.8 Output to fire alarm devices
Note: Products are available in various language groups as follows:
Group 0: English, Icelandic, French, Italian, Portuguese and Spanish, |
567au/08 |
ID62 | Single loop analogue addressable control and indicating equipment 002-461 ID62 Panel Group 0 002-461-001 ID62 Panel Group 1 002-461-004 ID62 Panel Group 4 Incorporating the following modular unit: 020-648 PSU3A Kit May also incorporate the following optional modular units: 020-479 RS485 Communication Kit 020-644-009 Printer Kit
Certified with the following options with requirements:
7.8 Output to fire alarm devices
Note: Products are available in various language groups as follows:
Group 0: English, Icelandic, French, Italian, Portuguese and Spanish, |
567au/09 |
NFS2-8 2 Zone | 002-477-122 Language region 1, light grey 002-477-129 Language region 1, black & grey 002-477-222 Language region 2, light grey 002-477-229 Language region 2, black & grey 002-477-322 Language region 3, light grey, dual relay 002-477-329 Language region 3, black & grey, dual relay, English manual 002-490-129 Language region 1, black & grey, dual relay, English manual 002-490-229 Language region 2, black & grey, dual relay, English manual 002-490-222 Language region 2, light grey, English manual
Incorporating the following units:
020-747 8-Way relay kit Certified with the following options from EN 54 Part 2:
7.8 Output to fire alarm devices Note 1: fixed build products incorporate a corresponding Basic equipment Kit. |
567au/10 |
NFS2-8 4 Zone | 002-477-142 Language region 1, light grey 002-477-149 Language region 1, black & grey 002-477-242 Language region 2, light grey 002-477-249 Language region 2, black & grey 002-477-342 Language region 3, light grey, dual relay 002-477-349 Language region 3, black & grey, dual relay 002-490-149 Language region 1, black & grey, dual relay, English manual 002-490-249 Language region 2, black & grey, dual relay, English manual 002-490-242 Language region 2, light grey, English manual
Incorporating the following units:
020-747 8-Way relay kit Certified with the following options from EN 54 Part 2:
7.8 Output to fire alarm devices Note 1: fixed build products incorporate a corresponding Basic equipment Kit. |
567au/11 |
NFS2-8 8 Zone | 002-477-182 Language region 1, light grey 002-477-189 Language region 1, black & grey 002-477-282 Language region 2, light grey 002-477-289 Language region 2, black & grey 002-477-382 Language region 3, light grey, dual relay 002-477-389 Language region 3, black & grey, dual relay 002-490-189 Language region 1, black & grey, dual relay, English manual 002-490-289 Language region 2, black & grey, dual relay, English manual 002-490-282 Language region 2, light grey, English manual
Incorporating the following units: 020-747 8-Way relay kit 020-772 4-way monitored sounder kit
Incorporating the following units:
020-747 8-Way relay kit Certified with the following options from EN 54 Part 2:
7.8 Output to fire alarm devices Note 1: fixed build products incorporate a corresponding Basic equipment Kit. |
567au/12 |
Pearl | Two loop analogue addressable control and indicating equipment
Incorporating the following units:
772489-NE CPU board
Incorporating the following optional regional language text inserts:
PRL-LED-EN (English) Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices
Notes:
1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Notes:
|
567au/19 |
To read the Red Book section introduction click here.