Search by Certificate Number

Apollo Fire Detectors Limited

36 Brookside Road
Havant
Hampshire
PO9 1JR
United Kingdom

Tel: +44 (0)2392 492412 • Fax: +44 (0)2392 492754
Email: enquiries@apollo-fire.co.uk


Certificate No 010h to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 & CEA 4021:2003
Certificate No 010m to EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003
Certificate No 010t to EN 54-7: 2000 & CEA 4021: 1999-06

Certificate No 010bb to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003
Certificate No 010be to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003


Multi-Sensor/Multi-Criteria Detectors

Product Description LPCB
Ref. No.
Orbis IS

Intrinsically safe multisensor detectors with Apollo Approval Reference* 50008

(Approved for use with base styles OB (+ATEX marking) and ORB-MB-50008-APO adapter base)

ORB-OH-53027-APO Orbis intrinsically safe multisensor detector with SensAlert, FasTest and DirtAlert

ORB-OH-53028-APO Orbis intrinsically safe multisensor detector with Flashing LED, SensAlert, FasTest and DirtAlert

010t/02
SA5100-700

Soteria Analogue Addressable Class A1R Optical Smoke/Heat Detector with Short Circuit Isolator
       (SA5000-200 and 45681-210 bases)

Certified at the following settings:

Mode 1: High sensitivity smoke detector with high heat enhancement

Mode 2: Standard smoke sensitivity only

Mode 3: Medium sensitivity smoke detector with medium heat enhancement

Mode 4: Low sensitivity smoke detector with high heat enhancement

Mode 5: Class A1R heat detector

010bb/01
SA5000-700

Soteria Analogue Addressable Class A1R Optical Smoke/Heat Detector

(SA5000-200 and 45681-210 bases)

Certified at the following settings:

Mode 1: High sensitivity smoke detector with high heat enhancement

Mode 2: Standard smoke sensitivity only

Mode 3: Medium sensitivity smoke detector with medium heat enhancement

Mode 4: Low sensitivity smoke detector with high heat enhancement

Mode 5: Class A1R heat detector

010be/01
58000-700SIL

Discovery Analogue Addressable Multisensor Detector (45681-209 and 45681-210 bases)

Notes:

1. Certified at the following settings:

Mode 1 - High sensitivity smoke detector with standard heat enhancement

Mode 2 - Smoke detection only

Mode 3 - Medium sensitivity smoke detector with standard heat enhancement

Mode 4 - Low sensitivity smoke detector with high heat enhancement

Mode 5 - Class A1 heat detector

Also approved in conventional alarm modes 1, 2, 3, 4 and 5

2. Approved with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery multisensor detector in accordance with manufacturer's instructions.

010h/01
SA5100-700LIM

Soteria Analogue Addressable Class A1R Optical Smoke/Heat Detector with Short Circuit Isolator
(SA5000-200 and 45681-210 bases)

Certified at the following settings:

Mode 1: High sensitivity smoke detector with high heat enhancement

Mode 2: Standard smoke sensitivity only

Mode 3: Medium sensitivity smoke detector with medium heat enhancement

Mode 4: Low sensitivity smoke detector with high heat enhancement

Mode 5: Class A1R heat detector

010bb/01
55000-885

XP95 Analogue addressable multisensor detector (45681-209 and 45681-210 mounting base)

Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols that have been configured for the Discovery multisensor detector

in accordance with manufacturer's instructions.

010m/01
58000-700 Discovery

Analogue addressable multisensor detector (45681-209 and 45681-210 mounting base)

Note: Certificated at the following settings.

Mode 1 - High sensitivity smoke detector with standard heat enhancement.

Mode 2 - Smoke detection only.

Mode 3 - Medium sensitivity smoke detector with standard heat enhancement.

Mode 4 - Low sensitivity smoke detector with high heat enhancement.

Mode 5 - Class A1 heat detector.

Also Certificated in conventional alarm modes 1, 2, 3, 4 and 5.

Certificated with Discovery XP95 and S90 digital communication protocols that have been configured for the Discovery multisensor detector in accordance with manufacturer's instructions.

010h/01
Orbis

Multisensor smoke detectors with Apollo Approval Reference* 00008 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base)  

ORB-OH-13001-APO Orbis multisensor smoke detector with SensAlert, FasTest and DirtAlert

ORB-OH-13003-APO Orbis multisensor smoke detector with Flashing LED, SensAlert, FasTest and DirtAlert

OEX-OH-13007-APO Orbis multisensor smoke detector with Flashing LED and SensAlert

OEX-OH-13016-APO Orbis multisensor smoke detector with SensAlert

010t/01

 

Bases:
45681-209 XP95/Discovery standard deep mounting base
45681-210 XP95 mounting base
SA5000-200 Addressable XPERT 8 Mounting Base
TimeSaver bases with Apollo Approval Reference* OB
TimeSaver LX bases with Apollo Approval Reference* OL
TimeSaver diode bases with Apollo Approval Reference* OD
TimeSaver relay bases with Apollo Approval Reference* OR
TimeSaver LX diode bases with Apollo Approval Reference* DX
TimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking)
ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207)
ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201)

* The Apollo ‘Approval Reference Number’ identifies a group of detectors that all have the same physical construction, but have features enabled or disabled via their software, and/or regional marking variations.  


 


 

To read the Red Book section introduction click here.

 

< back to results page

< back to search page