Morley-IAS by Honeywell, Pittway Tecnologica Srl

Via Caboto 19/3
Trieste
34147
Italy

Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888
Email: sales@morleyias.co.uk • Web: www.morley-ias.co.uk


Certificate No 567au-(cl-2) to EN 54-2:1997 + A1:2006, EN 54-4:1997 + A1:2002+A2:2006




Product Description LPCB
Ref. No.
ZX1Se

1 loop analogue addressable control and indicating equipment

722-001-301         1 loop multi-protocol control panel, language group M100

722-001-302         1 loop multi-protocol control panel, language group M200

722-002-301         1 loop multi-protocol control panel, language group M100,
                           Stainless Steel

722-101-301         1 loop multi-protocol control panel, language group H100

722-101-302         1 loop multi-protocol control panel, language group H200

Incorporating the following units:

        795-072-100        Morley-IAS Loop Driver Card

        795-068-100        System Sensor Loop Driver Card

        795-058-105        Hochiki Loop Driver Card

        795-066-100        Apollo XP95 / Discovery Loop Driver Card

        795-044-001        Nittan Loop Driver Card

        795-004-001        RS 485 Communication Module

        795-005        RS232 Communication Module

        124-206        Processor Card

        124-209-004         2 Loop Base Card

        124-370        4 Line Display Card

        PS82-2-NFR         2A PSU

Certified with the following options with requirements from EN 54-2:

        7.8        Output to fire alarm devices

        7.11         Delays to outputs

             7.12.3         Dependency on more than one alarm signal: Type C

        8.3        Fault signals from points

        9.5        Disablement of addressable points

             10        Test condition

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm system requirements of EN54-13.

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm system requirements of EN54-13

567au/01
ZX2Se

1-2 loop analogue addressable control and indicating equipment

720-001-301        1-2 loop multi-protocol control panel, language group M100

720-001-302        1-2 loop multi-protocol control panel, language group M200

720-002-301        1-2 loop multi-protocol control panel, language group M100,

                        Stainless Steel

720-101-301           1-2 loop multi-protocol control panel, language group H100

720-101-302           1-2 loop multi-protocol control panel, language group H200

Incorporating the following units:

795-072-100         Morley-IAS Loop Driver Card

795-068-100        System Sensor Loop Driver Card

795-058-105         Hochiki Loop Driver Card

795-066-100         Apollo XP95 / Discovery Loop Driver Card

795-044-001         Nittan Loop Driver Card

795-004-001        RS 485 Communication Module

795-005         RS232 Communication Module

124-206                 Processor Card

124-209-004         2 Loop Base Card

124-370 4              Line Display Card

PS82-2-NFR           2A PSU

Certified with the following options with requirements from EN 54-2:

7.8              Output to fire alarm devices

7.11            Delays to outputs

7.12.3         Dependency on more than one alarm signal: Type C

8.3              Fault signals from points

9.5              Disablement of addressable points

10                   Test condition

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm system requirements of EN54-13.

567au/02
ZX5Se

1-5 loop analogue addressable control and indicating equipment

721-001-301           1-5 loop multi-protocol control panel, language group M100

721-001-302           1-5 loop multi-protocol control panel, language group M200

721-002-301           1-5 loop multi-protocol control panel, language group M100,

        Stainless Steel

721-101-301           1-5 loop multi-protocol control panel, language group H100

721-101-302           1-5 loop multi-protocol control panel, language group H200

Incorporating the following units

795-072-100        Morley-IAS Loop Driver Card

795-068-100           System Sensor Loop Driver Card

795-058-105           Hochiki Loop Driver Card

795-066-100           Apollo XP95 / Discovery Loop Driver Card

795-044-001        Nittan Loop Driver Card

795-004-001         RS 485 Communication Module

795-005                 RS232 Communication Module

795-077-020         20 Zone LED Display Indicator Card

795-077-060         60 Zone LED Display Indicator Card

795-051-001         Internal Printer Module

124-206                Processor Card

124-403                5 Loop Base Card

124-370                4 Line Display Card

PS196-4-NFR         PSU

Certified with the following options with requirements from EN 54-2:

7.8                  Output to fire alarm devices

7.11                 Delays to outputs

7.12.3              Dependency on more than one alarm signal: Type C

8.3            Fault signals from points

9.5                   Disablement of addressable points

10           Test condition

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm system requirements of EN54-13.

567au/03
HRZ2-8 2 Zone

2 zone conventional control and indicating equipment

002-477-122         Language region 1, light grey

002-477-129         Language region 1, black & grey

002-477-222         Language region 2, light grey

002-477-229         Language region 2, black & grey

002-477-322         Language region 3, light grey, dual relay

002-477-329         Language region 3, black & grey, dual relay, English manual

002-490-129         Language region 1, black & grey, dual relay, English manual

002-490-229         Language region 2, black & grey, dual relay, English manual

002-490-222         Language region 2, light grey, English manual

Incorporating the following units:

020-747        8-Way relay kit

020-772        4-way monitored sounder kit

Certified with the following options from EN 54 Part 2:

7.8                 Output to fire alarm devices

7.9.1                 Output to fire alarm routing equipment

7.9.2                Alarm confirmation input from fire alarm routing equipment

7.10.1                Output to automatic fire protection equipment: Type A

7.10.3                Output to automatic fire protection equipment: Type C

7.10.4                Fault monitoring of fire protection equipment

7.11.1                Delays to outputs

7.11.2                Manual or automatic switching of delays to outputs

7.12.2                Dependency on more than one alarm signal: Type B

8.9                Output to fault warning routing equipment

10                 Test condition

Notes:

1.        Fixed build products incorporate a corresponding Basic equipment Kit.

2.        Scope of approval does not include the operation of the network functionality

3.        This product approval does not constitute compliance with the fire detection and alarm system requirements of EN54-13.

567au/10
HRZ2-8 4 Zone

4 zone conventional control and indicating equipment

002-477-142         Language region 1, light grey

002-477-149         Language region 1, black & grey

002-477-242         Language region 2, light grey

002-477-249         Language region 2, black & grey

002-477-342         Language region 3, light grey, dual relay

002-477-349        Language region 3, black & grey, dual relay

002-490-149         Language region 1, black & grey, dual relay, English manual

002-490-249         Language region 2, black & grey, dual relay, English manual

002-490-242         Language region 2, light grey, English manual

Incorporating the following units:

020-747        8-Way relay kit

020-772        4-way monitored sounder kit

Certified with the following options from EN 54 Part 2:

7.8                 Output to fire alarm devices

7.9.1                 Output to fire alarm routing equipment

7.9.2                Alarm confirmation input from fire alarm routing equipment

7.10.1                Output to automatic fire protection equipment: Type A

7.10.3                Output to automatic fire protection equipment: Type C

7.10.4                Fault monitoring of fire protection equipment

7.11.1                Delays to outputs

7.11.2                Manual or automatic switching of delays to outputs

7.12.2                Dependency on more than one alarm signal: Type B

8.9                Output to fault warning routing equipment

10                 Test condition

Notes:
1. Fixed build products incorporate a corresponding Basic equipment Kit.

  2. Scope of approval does not include the operation of the network functionality

3. This product approval does not constitute compliance with the fire detection and alarm system requirements of EN54-13.

567au/11
HRZ2-8 8 Zone

8 zone conventional control and indicating equipment

002-477-182         Language region 1, light grey                        

002-477-189         Language region 1, black & grey

002-477-282         Language region 2, light grey

002-477-289         Language region 2, black & grey

002-477-382         Language region 3, light grey, dual relay

002-477-389        Language region 3, black & grey, dual relay

002-490-189         Language region 1, black & grey, dual relay, English manual

002-490-289         Language region 2, black & grey, dual relay, English manual

002-490-282         Language region 2, light grey, English manual

Incorporating the following units:

020-747        8-Way relay kit

020-772        4-way monitored sounder kit

Certified with the following options from EN 54 Part 2:

7.8                 Output to fire alarm devices

7.9.1                 Output to fire alarm routing equipment

7.9.2                Alarm confirmation input from fire alarm routing equipment

7.10.1                Output to automatic fire protection equipment: Type A

7.10.3                Output to automatic fire protection equipment: Type C

7.10.4                Fault monitoring of fire protection equipment

7.11.1                Delays to outputs

7.11.2                Manual or automatic switching of delays to outputs

7.12.2                Dependency on more than one alarm signal: Type B

8.9                Output to fault warning routing equipment

10                 Test condition

Notes:
1. Fixed build products incorporate a corresponding Basic equipment Kit.

  2. Scope of approval does not include the operation of the network functionality

3. This product approval does not constitute compliance with the fire detection and alarm system requirements of EN54-13.

567au/12
DXc1-S

Single loop control and indicating equipment

714-001-111 PANEL DXc1-S SINGLE LOOP REGION 1(MIAS/Apollo/System Sensor protocol)                                                                                  

714-001-112 PANEL DXc1-S SINGLE LOOP REGION 2 (MIAS protocol)                                                                                

714-001-113 PANEL DXc1-S SINGLE LOOP REGION 3 (MIAS protocol)                                                                                

714-001-114 PANEL DXc1-S SINGLE LOOP REGION 4 (MIAS protocol)                                                                                

714-001-115 PANEL DXc1-S SINGLE LOOP REGION 5 (MIAS protocol)

Incorporating as modular units:

124-410-001        Base PCB 1 Loop  

124-411        Display PCB          

010-115         PSU RS-50-24

Certified with the following options with requirements from EN 54-2:

7.8         Output to fire alarm devices

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal - Type B

7.12.3         Dependencies on more than one alarm signal - Type C

7.13         Alarm counter

8.3         Fault signals from points

9.5         Disablement of each address points

10         Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.  

3.  The regions are related to different market areas

567au/15
DXc2-M

Two loop control and indicating equipment

714-001-221 PANEL DXc2-M TWO LOOP REGION 1 (MIAS/Apollo/System Sensor protocol)                                                                                  

714-001-222 PANEL DXc2-M TWO LOOP REGION 2 (MIAS protocol)                                                                                

714-001-223 PANEL DXc2-M TWO LOOP REGION 3 (MIAS protocol)                                                                                

714-001-224 PANEL DXc2-M TWO LOOP REGION 4 (MIAS protocol)                                                                              

714-001-225 PANEL DXc2-M TWO LOOP REGION 5 (MIAS protocol)                                                                              

714-001-226 PANEL DXc2-M TWO LOOP REGION 6 (System Sensor protocol)  

                                                                      

Incorporating as modular units:

124-410        Base PCB 2 Loop    

124-411        Display PCB            

010-116        PSU RS-100-24      

Incorporating as optional modular units:

124-414 DXn Zone Expansion PCB

124-429 Loop Splitter PCB

124-430 DXc System I/O PCB (note: cannot be fitted with 124-414)

124-300 RS232 I/F

Certified with the following options with requirements from EN 54-2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.9.2         Alarm confirmation input from fire alarm routing equipment

7.10.1         Output to fire protection equipment - Output type A

7.10.2         Output to fire protection equipment - Output type B

7.10.3         Output to fire protection equipment - Output type C

7.10.4         Fault monitoring of fire protection equipment

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal - Type B

7.12.3         Dependencies on more than one alarm signal - Type C

7.13         Alarm counter

8.3         Fault signals from points

8.9         Output to fault warning routing equipment

9.5         Disablement of each address points

10         Test condition

Notes:

1. This product approval does not constitute compliance with the fire

detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network

functionality.

3.  The regions are related to different market areas.  

567au/16
DXc4-M

Four loop control and indicating equipment

714-001-241 PANEL DXc4-M FOUR LOOP REGION 1 (MIAS/Apollo/System Sensor protocol)

714-001-242 PANEL DXc4-M FOUR LOOP REGION 2 (MIAS protocol)                                                                                

714-001-243 PANEL DXc4-M FOUR LOOP REGION 3 (MIAS protocol)

714-001-244 PANEL DXc4-M FOUR LOOP REGION 4 (MIAS protocol)                                                                              

714-001-245 PANEL DXc4-M FOUR LOOP REGION 5 (MIAS protocol)                                                                                

Incorporating as modular units:

124-410        Base PCB 2 Loop                

124-411        Display PCB                

124-417         2 Loop PCB

010-116         PSU RS-100-24

Incorporating as optional modular units:

124-414 DXn Zone Expansion PCB

124-429 Loop Splitter PCB

124-430 DXc System I/O PCB (note: cannot be fitted with 124-414)

124-300 RS232 I/F

Certified with the following options with requirements from EN 54-2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1         Output to fire protection equipment - Output type A

7.10.2         Output to fire protection equipment - Output type B

7.10.3         Output to fire protection equipment - Output type C

7.10.4         Fault monitoring of fire protection equipment

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal - Type B

7.12.3         Dependencies on more than one alarm signal - Type C

7.13         Alarm counter

8.3         Fault signals from points

8.9         Output to fault warning routing equipment

9.5         Disablement of each address points

10         Test condition

Notes:

1. This product approval does not constitute compliance with the fire

detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network

functionality.  

3.  The regions are related to different market areas.

567au/17
DXc1-M

Single loop control and indicating equipment

714-001-213 PANEL DXc1-M SINGLE LOOP REGION 3 (MIAS protocol)

714-001-214 PANEL DXc1-M SINGLE LOOP REGION 4 (MIAS protocol)  


Incorporating as modular units:

124-410-001         Base PCB 1 Loop

124-411         Display PCB

010-115        PSU RS-50-24

Incorporating as optional modular units:

124-414 DXn Zone Expansion PCB

124-429 Loop Splitter PCB

124-430 DXc System I/O PCB (note: cannot be fitted with 124-414)

124-300 RS232 I/F

Certified with the following options with requirements from EN 54-2:

7.8         Output to fire alarm devices

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal - Type B

7.12.3         Dependencies on more than one alarm signal - Type C

7.13         Alarm counter

8.3         Fault signals from points

9.5         Disablement of each address points

10         Test condition

Notes:

1. This product approval does not constitute compliance with the fire

     detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network

     functionality.

3.  The regions are related to different market areas.

567au/18

 

 


 