Certificate No 429c to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006




Product Description LPCB
Ref. No.
DXc1-S

Single loop control and indicating equipment
714-001-111 PANEL DXc1-S SINGLE LOOP REGION 1 (MIAS/Apollo/System Sensor protocol)                                                                                  

714-001-112 PANEL DXc1-S SINGLE LOOP REGION 2 (MIAS protocol)                                                                                

714-001-113 PANEL DXc1-S SINGLE LOOP REGION 3 (MIAS protocol)                                                                                

714-001-114 PANEL DXc1-S SINGLE LOOP REGION 4 (MIAS protocol)                                                                                

714-001-115 PANEL DXc1-S SINGLE LOOP REGION 5 (MIAS protocol)                                                                                

Incorporating as modular units:

124-410-001        Base PCB 1 Loop  

124-411        Display PCB          

010-115         PSU RS-50-24

Certified with the following options with requirements from EN 54-2:

7.8         Output to fire alarm devices

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal - Type B

7.12.3         Dependencies on more than one alarm signal - Type C

7.13         Alarm counter

8.3         Fault signals from points

9.5         Disablement of each address points

10         Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.  

3.  The regions are related to different market areas

567au/15
DXc2-M

Two loop control and indicating equipment

714-001-221 PANEL DXc2-M TWO LOOP REGION 1 (MIAS/Apollo/System Sensor protocol)

714-001-222 PANEL DXc2-M TWO LOOP REGION 2 (MIAS protocol)                                                                                

714-001-223 PANEL DXc2-M TWO LOOP REGION 3 (MIAS protocol)                                                                                

714-001-224 PANEL DXc2-M TWO LOOP REGION 4 (MIAS protocol)                                                                              

714-001-225 PANEL DXc2-M TWO LOOP REGION 5 (MIAS protocol)                                                                              

714-001-226 PANEL DXc2-M TWO LOOP REGION 6 (System Sensor protocol)                                                                          

Incorporating as modular units:

124-410        Base PCB 2 Loop    

124-411        Display PCB            

010-116                PSU RS-100-24      

Incorporating as optional modular units:

124-414 DXn Zone Expansion PCB

124-429 Loop Splitter PCB

124-430 DXc System I/O PCB (note: cannot be fitted with 124-414)

124-300 RS232 I/F

Certified with the following options with requirements from EN 54-2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.9.2         Alarm confirmation input from fire alarm routing equipment

7.10.1         Output to fire protection equipment - Output type A

7.10.2         Output to fire protection equipment - Output type B

7.10.3         Output to fire protection equipment - Output type C

7.10.4         Fault monitoring of fire protection equipment

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal - Type B

7.12.3         Dependencies on more than one alarm signal - Type C

7.13         Alarm counter

8.3         Fault signals from points

8.9         Output to fault warning routing equipment

9.5         Disablement of each address points

10         Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.

3.  The regions are related to different market areas.

567au/16
DXc4-M

Four loop control and indicating equipment

714-001-241 PANEL DXc4-M FOUR LOOP REGION 1 (MIAS/Apollo/System Sensor protocol)

714-001-242 PANEL DXc4-M FOUR LOOP REGION 2 (MIAS protocol)                                                                                

714-001-243 PANEL DXc4-M FOUR LOOP REGION 3 (MIAS protocol)                    

714-001-244 PANEL DXc4-M FOUR LOOP REGION 4 (MIAS protocol)                                                                              

714-001-245 PANEL DXc4-M FOUR LOOP REGION 5 (MIAS protocol)                                                                                

Incorporating as modular units:

124-410        Base PCB 2 Loop                

124-411        Display PCB                

124-417         2 Loop PCB

010-116         PSU RS-100-24

Incorporating as optional modular units:

124-414 DXn Zone Expansion PCB

124-429 Loop Splitter PCB

124-430 DXc System I/O PCB (note: cannot be fitted with 124-414)

124-300 RS232 I/F

Certified with the following options with requirements from EN 54-2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1         Output to fire protection equipment - Output type A

7.10.2         Output to fire protection equipment - Output type B

7.10.3         Output to fire protection equipment - Output type C

7.10.4         Fault monitoring of fire protection equipment

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal - Type B

7.12.3         Dependencies on more than one alarm signal - Type C

7.13         Alarm counter

8.3         Fault signals from points

8.9         Output to fault warning routing equipment

9.5         Disablement of each address points

10         Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.  

3.  The regions are related to different market areas.

567au/17
DXc1-M

Single loop control and indicating equipment

714-001-213 PANEL DXc1-M SINGLE LOOP REGION 3 (MIAS protocol)
714-001-214 PANEL DXc1-M SINGLE LOOP REGION 4 (MIAS protocol)  

                                                                            

Incorporating as modular units:

124-410-001         Base PCB 1 Loop

124-411         Display PCB

010-115        PSU RS-50-24

Incorporating as optional modular units:

124-414 DXn Zone Expansion PCB

124-429 Loop Splitter PCB

124-430 DXc System I/O PCB (note: cannot be fitted with 124-414)

124-300 RS232 I/F

Certified with the following options with requirements from EN 54-2:

7.8         Output to fire alarm devices

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal - Type B

7.12.3         Dependencies on more than one alarm signal - Type C

7.13         Alarm counter

8.3         Fault signals from points

9.5         Disablement of each address points

10         Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.

3.  The regions are related to different market areas.

567au/18
ZX1Se

1 loop analogue addressable control and indicating equipment

722-001-301         1 loop multi-protocol control panel, language group M100

722-001-302         1 loop multi-protocol control panel, language group M200

722-002-301         1 loop multi-protocol control panel, language group M100,         Stainless Steel

722-101-301         1 loop multi-protocol control panel, language group H100

722-101-302         1 loop multi-protocol control panel, language group H200

Incorporating the following units:

795-072-100        Morley-IAS Loop Driver Card

795-068-100        System Sensor Loop Driver Card

795-058-105        Hochiki Loop Driver Card

795-066-100        Apollo XP95 / Discovery Loop Driver Card

795-044-001        Nittan Loop Driver Card

795-004-001        RS 485 Communication Module

795-005                RS232 Communication Module

124-206                Processor Card

124-209-005         1 Loop Base Card

124-370                4 Line Display Card

PS82-2-NFR         2A PSU

Certified with the following options with requirements from EN 54-2:7.8

7.8                Output to fire alarm devices

7.11         Delays to outputs

7.12.3         Dependency on more than one alarm signal: Type C

8.3        Fault signals from points

9.5        Disablement of addressable points

10        Test condition

xxxx
ZX2Se

1-2 loop analogue addressable control and indicating equipment

720-001-301         1-2 loop multi-protocol control panel, language group M100

720-001-302         1-2 loop multi-protocol control panel, language group M200

720-002-301         1-2 loop multi-protocol control panel, language group M100, Stainless Steel

720-101-301         1-2 loop multi-protocol control panel, language group H100

720-101-302         1-2 loop multi-protocol control panel, language group H200

Incorporating the following units:

795-072-100        Morley-IAS Loop Driver Card

795-068-100        System Sensor Loop Driver Card

795-058-105        Hochiki Loop Driver Card

795-066-100        Apollo XP95 / Discovery Loop Driver Card

795-044-001        Nittan Loop Driver Card

795-004-001        RS 485 Communication Module

795-005                RS232 Communication Module

124-206                Processor Card

124-209-004         2 Loop Base Card

124-370        4         Line Display Card

PS82-2-NFR         2A PSU

        

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.11         Delays to outputs

7.12.3         Dependency on more than one alarm signal: Type C

8.3        Fault signals from points

9.5        Disablement of addressable points

10        Test condition

567au/02
ZX5Se

1-5 loop analogue addressable control and indicating equipment

721-001-301         1-5 loop multi-protocol control panel, language group M100

721-001-302         1-5 loop multi-protocol control panel, language group M200

721-002-301         1-5 loop multi-protocol control panel, language group M100, Stainless Steel

721-101-301         1-5 loop multi-protocol control panel, language group H100

721-101-302         1-5 loop multi-protocol control panel, language group H200

Incorporating the following units:

795-072-100        Morley-IAS Loop Driver Card

795-068-100        System Sensor Loop Driver Card

795-058-105        Hochiki Loop Driver Card

795-066-100        Apollo XP95 / Discovery Loop Driver Card

795-044-001        Nittan Loop Driver Card

795-004-001        RS 485 Communication Module

795-005                RS232 Communication Module

795-077-020         20 Zone LED Display Indicator Card

795-077-060         60 Zone LED Display Indicator Card

795-051-001         Internal Printer Module

124-206                Processor Card

124-403                5 Loop Base Card

124-370        4         Line Display Card

PS196-4-NFR         PSU                

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.11         Delays to outputs

7.12.3         Dependency on more than one alarm signal: Type C

8.3        Fault signals from points

9.5        Disablement of addressable points

10        Test condition

567au/03
HRZ2-8e 2 Zone

002-479-122 Language region 1, English manual

002-479-222 Language region 2

002-479-322 Language region 3, dual relay

002-492-222 Language region 2, English manual, dual relay

002-506-222 Language region 2, English manual

Incorporating the following units:

020-747        8-way relay kit

020-772        4-way monitored sounder kit

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Output to automatic fire protection equipment: Type A

7.10.3        Output to automatic fire protection equipment: Type C

7.10.4        Fault monitoring of fire protection equipment

7.11.1        Delays to outputs

7.11.2        Manual or automatic switching of delays to outputs

7.12.2        Dependency on more than one alarm signal: Type B

8.9        Output to fault warning routing equipment

10        Test condition

567au/10
HRZ2-8e 4 Zone

002-479-142 Language region 1, English manual

002-479-242 Language region 2

002-479-342 Language region 3, dual relay

002-492-242 Language region 2, English manual, dual relay

002-506-242 Language region 2, English manual

Incorporating the following units:

020-747        8-way relay kit

020-772        4-way monitored sounder kit

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Output to automatic fire protection equipment: Type A

7.10.3        Output to automatic fire protection equipment: Type C

7.10.4        Fault monitoring of fire protection equipment

7.11.1        Delays to outputs

7.11.2        Manual or automatic switching of delays to outputs

7.12.2        Dependency on more than one alarm signal: Type B

8.9        Output to fault warning routing equipment

10        Test condition

567au/11
HRZ2-8e 8 Zone

002-479-182 Language region 1, English manual

002-479-282 Language region 2

002-479-382 Language region 3, dual relay

002-492-282 Language region 2, English user manual, dual relay

002-506-282 Language region 2, English user manual

Incorporating the following units:

020-747        8-way relay kit

020-772        4-way monitored sounder kit

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Output to automatic fire protection equipment: Type A

7.10.3        Output to automatic fire protection equipment: Type C

7.10.4        Fault monitoring of fire protection equipment

7.11.1        Delays to outputs

7.11.2        Manual or automatic switching of delays to outputs

7.12.2        Dependency on more than one alarm signal: Type B

8.9        Output to fault warning routing equipment

10        Test condition

567au/12

 

 


 