7, rue du Saule Trapu
MASSY
91300
France

Tel: +33 (0) 160136772
Email: frederic.chateau@coflec.com


Certificate No 1549d-(cl-1) to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 + A2:2006, EN 54-17:2005, EN 54-18:2005 & EN 54-29:2015
Certificate No 1549h-(cl-1) to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 + A2:2006, EN 54-17:2005, EN 54-18:2005 & EN 54-31:2014 + A1:2016


Multi-Sensor/Multi-Criteria Detectors

Product Description LPCB
Ref. No.
LOTA

Multi-Sensor Detector with Short Circuit Isolator and Input/Output device (FC012M and FC039M bases)

Notes:

1.  Certified at the following settings for EN 54-29:

- Behaviour 1: Medium sensitivity & normal heat combination

- Behaviour 2: Medium sensitivity & high heat combination

- Behaviour 3: Standard sensitivity & normal heat combination

- Behaviour 4: Standard sensitivity & high heat combination

- Behaviour 5: Low sensitivity & normal heat combination

- Behaviour 6: Low sensitivity & high heat combination

2. Meets the requirements of EN 54-5 for the following settings:

- Behaviour 7: A1S

- Behaviour 8: A2S

- Behaviour 9: BS

- Behaviour 10: A1R

- Behaviour 11: A2R

- Behaviour 12: BR

3.  Certified at the following EN 54-7 sensitivity settings:

- Behaviour 13: High sensitivity

- Behaviour 14: Medium sensitivity

- Behaviour 15: Standard sensitivity

- Behaviour 16: Low sensitivity

4. The product complies with EN 54-18 only when the base FC039M is used

1549d/01
LOTAI

Multi-Sensor Detector with Short Circuit Isolator and Input/Output device (FC012M and FC039M bases)

Notes:

1.  Certified at the following settings for EN 54-29:

- Behaviour 1: Medium sensitivity & normal heat combination

- Behaviour 2: Medium sensitivity & high heat combination

- Behaviour 3: Standard sensitivity & normal heat combination

- Behaviour 4: Standard sensitivity & high heat combination

- Behaviour 5: Low sensitivity & normal heat combination

- Behaviour 6: Low sensitivity & high heat combination

2. Meets the requirements of EN 54-5 for the following settings:

- Behaviour 7: A1S

- Behaviour 8: A2S

- Behaviour 9: BS

- Behaviour 10: CS

- Behaviour 11: A1R

- Behaviour 12: A2R

- Behaviour 13: BR

- Behaviour 14: CR

3.  Certified at the following EN 54-7 sensitivity settings:

- Behaviour 15: High sensitivity

- Behaviour 16: Medium sensitivity

- Behaviour 17: Standard sensitivity

- Behaviour 18: Low sensitivity

4. The product complies with EN 54-18 only when the base FC039M is used

1549d/02
LOTCA

Addressable Multi-sensor Point Detector with Short Circuit Isolator and Input/Output Device (FC012M and FC039M bases)

Note:

1.  Certified at the following settings for EN 54-31:

- Behaviour 1: High sensitivity & CO combination & normal heat combination

- Behaviour 2: Medium sensitivity & CO combination & high heat combination

- Behaviour 3: Standard sensitivity & CO combination & normal heat combination

- Behaviour 4: Dur & CO combination & high heat combination

2. Meets the requirements of EN 54-5 for the following settings:

- Behaviour 5: A1S

- Behaviour 6: A2S

- Behaviour 7: A1R

- Behaviour 8: A2R

3.  Certified at the following EN 54-7 sensitivity settings:

- Behaviour 9: Very sensitive - Lowest response values

- Behaviour 10: Sensitive - Intermediate response values

- Behaviour 11: Standard - Intermediate response values

- Behaviour 12: Hard - Highest response values

4. The product complies with EN 54-18 only when the base FC039M is used

1549h/01

 

    FC012M    Base with screw terminal
    FC039M  Base with options; with SHUNT, SHUNT & output relay NO, SHUNT & output relay NC

 


 

To read the Red Book section introduction click here.

 