KAC House
Thornhill Road
North Moons Moat
Redditch
Worcestershire
B98 9ND
United Kingdom
Tel: +44 (0)1527 406655
•
Fax: +44 (0)1527 406677
Email: sales@kac.co.uk OR marketing@kac.co.uk
•
Web: www.kac.co.uk
Certificate No 166b to EN 54-11: 2001 + A1: 2005
Product | Description | LPCB Ref. No. |
---|---|---|
MCP6H-RC01xx-yyyy-zz | Indoor surface/flush mounting conventional call point Notes: 1. RC01Xx indicates mounting (S=Surface mounted, F=Flush mounted, P=Pattress mounted, 1-4= Surface mounted with 1-4 terminals) 2. RC01xG (Glass element) RC01xF (Flexible element) 3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639. |
166b/69 |
MCP6V-RC01xx-yyyy-zz | Indoor surface/flush mounting conventional call point Notes: 1. RC01Xx indicates mounting (S=Surface mounted, F=Flush mounted, P=Pattress mounted, 1-4= Surface mounted with 1-4 terminals) 2. RC01xG (Glass element) RC01xF (Flexible element) 3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639. |
166b/70 |
MCP1A-Rxxxxx-yyyy-zz | IIndoor surface/flush mounting conventional call point |
166b/39 |
MCP1A-Rxxxxx-yyyy-zzIS | Indoor surface/flush mounting conventional call point |
166b/39 |
MCP1B-Rxxxxx-yyyy-zz | Indoor surface/flush mounting conventional call point |
166b/40 |
MCP1B-Rxxxxx-yyyy-zzIS | Indoor surface/flush mounting conventional call point |
166b/40 |
MCP2A-Rxxxxx-yyyy-zz | Indoor surface/flush mounting conventional call point |
166b/41 |
MCP2A-Rxxxxx-yyyy-zzIS | Indoor surface/flush mounting conventional call point |
166b/41 |
MCP2B-Rxxxxx-yyyy-zz | Indoor surface/flush mounting conventional call point |
166b/42 |
MCP2B-Rxxxxx-yyyy-zzIS | Indoor surface/flush mounting conventional call point Notes: 1. XXXxx indicates the series resistor value 039xx (lowest 39 Ω), 4K7xx (highest 4.7 kΩ) 2. xxxXx indicates mounting (S=Surface mounted, F=Flush mounted, P=Pattress mounted, 1-4= Surface mounted with 1-4 terminals) 3. xxxxG (Glass element) xxxxF (Flexible element) 4. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 5. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 6. IS indicates the intrinsically safe version. |
166b/42 |
MCP3A-Rxxxxx-yyyy-zz | Indoor surface/flush mounting conventional call point |
166b/43 |
MCP3A-Rxxxxx-yyyy-zzIS | Indoor surface/flush mounting conventional call point Notes: 1. XXXxx indicates the electrical configuration (000xx = no resistor, C01xx = single pole changeover connections) 2. xxxXx indicates mounting (S=Surface mounted, F=Flush mounted, P=Pattress mounted, 1-4= Surface mounted with 1-4 terminals) 3. xxxxG (Glass element) xxxxF (Flexible element) 4. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 5. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 6. IS indicates the intrinsically safe version. |
166b/43 |
MCP4A-R000xx-yyyy-zz | Indoor surface/flush mounting conventional call point |
166b/44 |
MCP4A-R000xx-yyyy-zzIS | Indoor surface/flush mounting conventional call point Notes: 1. Xx indicates mounting (S=Surface mounted, F=Flush mounted, P=Pattress mounted, 1-4= Surface mounted with 1-4 terminals) 2. xG (Glass element) xF (Flexible element)
3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer presence of the LPCB logo placed on the product label 4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 5. IS indicates the intrinsically safe version. |
166b/44 |
MCP5A-RP01wwxx-yyyy-zz | Indoor surface/flush mounting addressable call point Advanced Protocol (and System Sensor 500 series protocol) |
166b/45 |
MCP5A-RP03wwxx-yyyy-zz | Indoor surface/flush mounting addressable call point Advanced Protocol (and Honeywell 500 series protocol) Notes: 1. ww (Range 0-99 odd numbers only) indicates the communication software protocol 2. wwXx indicates mounting (S=Surface mounted, F=Flush mounted, P=Pattress mounted, 1-4= Surface mounted with 1-4 terminals) 3. xG (Glass element) xF (Flexible element) 4. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 5. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 6. IS indicates the intrinsically safe version. |
166b/47 |
WCP1A-RxxxSx-yyyy-zz | Outdoor surface mounting conventional waterproof call point |
166b/51 |
WCP1A-RxxxSx-yyyy-zzIS | Outdoor surface mounting conventional waterproof call point |
166b/51 |
WCP1B-RxxxSx-yyyy-zz | Outdoor surface mounting conventional waterproof call point |
166b/52 |
WCP1B-RxxxSx-yyyy-zzIS | Outdoor surface mounting conventional waterproof call point |
166b/52 |
WCP2A-RxxxSx-yyyy-zz | Outdoor surface mounting conventional waterproof call point |
166b/53 |
WCP2A-RxxxSx-yyyy-zzIS | Outdoor surface mounting conventional waterproof call poin |
166b/53 |
WCP2B-RxxxSx-yyyy-zz | Outdoor surface mounting conventional waterproof call point |
166b/54 |
WCP2B-RxxxSx-yyyy-zzIS | Outdoor surface mounting conventional waterproof call point Notes: 1. XXXxx indicates the series resistor value 039xx (lowest 39 Ω), 4K7xx (highest 4.7 kΩ) 2. xxxSG (Glass element) xxxSF (Flexible element) 3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code.
Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on 4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 5. IS indicates the intrinsically safe version. |
166b/54 |
WCP3A-RxxxSx-yyyy-zz | Outdoor surface mounting conventional waterproof call point |
166b/55 |
WCP3A-RxxxSx-yyyy-zzIS | Outdoor surface mounting conventional waterproof call point Notes:
1.XXXSx indicates the electrical configuration (000Sx = no resistor, C01Sx = single pole changeover 2. xxxSG (Glass element) xxxSF (Flexible element) 3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code.
Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on 4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 5. IS indicates the intrinsically safe version. |
166b/55 |
WCP4A-R000Sx-yyyy-zz | Outdoor surface mounting conventional waterproof call point |
166b/56 |
WCP4A-R000Sx-yyyy-zzIS | Outdoor surface mounting conventional waterproof call point Notes: 1. SG (Glass element) SF (Flexible element)
2. yyyy (Range A000 to Z999 or STCK for standard stocked product),indicates a
3. zz (Range 0-99) indicates customer marking options detailed on KAC 4. IS indicates the intrinsically safe version. |
166b/56 |
WCP5A-RPwwSx-yyyy-zz | Outdoor surface mounting addressable waterproof call point Advanced Protocol (and System Sensor 500 series protocol) |
166b/57 |
WCP5A-RPwwSx-yyyy-zz | Outdoor surface mounting addressable waterproof call point Advanced Protocol (and Honeywell 500 series protocol) Notes: 1. ww (Range 0-99 odd numbers only) indicates the communication software protocol 2. SG (Glass element) SF (Flexible element) 3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 5. IS indicates the intrinsically safe version. |
166b/59 |
MCP5A-RP07xx-zz | Indoor surface/flush mounting addressable call point (Labor Strauss protocol) Advanced Protocol (and Labor Strauss protocol) Notes: 1. Xx indicates mounting (S=Surface mounted, F=Flush mounted, P=Pattress mounted, 1-4= Surface mounted with 1-4 terminals) 2. xG (Glass element) xF (Flexible element) 3. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639. |
166b/67 |
WCP5A-RP07Sx-zz | Outdoor surface mounting addressable call point Advanced Protocol (and Labor Strauss protocol) Notes:
1. SG (Glass element) SF (Flexible element) |
166b/68 |
Accessories:
To read the Red Book section introduction click here.