Search by Certificate Number

Siemens Switzerland Ltd

Theilerstrasse 1a
CH-6300 Zug
Switzerland

Web: www.siemens.com


Certificate No 126bg to EN 54-7:2000 + A1:2002 + A2:2006, EN 54-17:2005, CEA 4021:2003
Certificate No 531d-(cl-1) to EN 54-7:2000 + A1:2002 + A2:2006, EN 54-17:2005, CEA 4021:2003-07
Certificate No 126bv to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 + A2:2006, EN 54-17:2005, EN 54-29:2015




Product Description LPCB
Ref. No.
FDOOT221

Analogue Addressable Multisensor Detector with Short Circuit Isolator (FDB221, FDB222, FD291 and FDB293 bases)

Note:

Meets the requirements of EN 54-7:2000 at sensitivity settings:

Parameter No. 2 Robust with thermal enhancement

Parameter No. 4 balanced with thermal enhancement

126bg/01
OH720

Analogue Addressable Multi Sensor Smoke Detector

(DB720, DB721 bases)

Note:

1)        Meets the requirements of EN 54-7 in the following sensitivities:

1 - Robust 3.5%/m

2 - Sensitive 2.5%/m

531d/01
FDOOT241-A5

Addressable Optical Smoke and Heat Multi-Sensor Detector with Short Circuit Isolator

(DB1151A, FDB251, FDB295, FDB221, FDB222 & FDB291 Bases)

Notes:

1.  The following modes are approved when used with Sinteso FDnet protocol:

Mode 0 - "Neural Fire Detector"

Parameter                 No

Robust                        2

Balanced                4

Suppression                5

Fast Response                6

High Compensation        7

High Sensitive Fast        9

Super Sensitive                11

Mode 1 - "Heat Detector"

Parameter                 No

A1R                        1

BR                        2

A1S                        3

BS                        4

Mode 2 - "Smoke Detector"

Parameter                 No

Universal                1

Robust        2                

Sensitive                3

Super Sensitive                5

2.  The following modes are approved when used with the AlgoRex Interactive protocol:

Mode 0 - "Neural Fire Detector"

Parameter                 No

Balanced                4

Suppression                5

Fast Response                6

High Sensitive Fast        9

Super Sensitive                11

Mode 1 - "Heat Detector"

Parameter                 No

A1R                        1

BR                        2

A1S                        3

BS                        4

Mode 2 - "Smoke Detector"

Parameter                 No

Universal                1

Sensitive                3

Super Sensitive                5

3. Refer to manufacturer's documentation A6V10323158 when making changes to interactive protocol and replacing the following detectors.

DOT1151A, DOT1152A replaced by FDOOT241-A5

Mode 0 - "Neural Fire Detector - Multisensor Detector"

Parameter                No         legacy setting         

Balanced                4        APS005S, APS006S, APS015S, APS019S, APS009S, APS082S

Suppression                5        APS084S

Fast Response                6        APS007S, APS085S

High Sensitive Fast        9        APS081S

Super Sensitive                11        APS080S

DT1152A replaced by FDOOT241-A5

Mode 1 - "Heat Detector"

Parameter                No        legacy setting

A1R                        1        APS100T

BR                        2        APS105T

A1S                        3        APS103T

BS                        4        APS107T

Smoke detector DO1151A, DO1152A replaced by FDOOT241-A5

Mode 2 - "Smoke detector"

Parameter                No        legacy setting

Universal                 1        APS005S

Sensitive                3        APS006S

Super Sensitive                5        APS007S, APS009S

Smoke detector DO1153A replaced by FDOOT241-A5

Mode 2 - "Smoke detector"

Parameter                No        legacy setting

Super Sensitive                5        APS073SH

126bv/01
FDOOT241-A3

Multisensor Detector with Short Circuit Isolator

(FDB221, FDB222, DB1131A, FDB291, FDB293 and FDB241 bases)

Note - the following modes are approved

1 - Parameter sets for detection when connected to FDnet communication

Protocol

Mode 0 - "Neural Fire Detector-Multisensor Detector":

Parameter         No

Robust         2

Balanced         4

Suppression         5

Fast Response         6

High Compensation         7

High Sensitive Fast         9

Super Sensitive        11

Mode 1 - "Heat Detector"

Parameter         No

A1R         1

BR         2

A1S         3

BS         4

Mode 2 - "Smoke Detector"

Parameter         No

Universal         1

Robust         2

Sensitive         3

Super Sensitive                5

2 - Parameter sets for detection when connected to AnalogPLUS

communication protocol

Smoke only as DO1131A

Parameter         No

Sensitive         3

Universal Fast         4

Smoke with heat enhancement as DOT1131A

Parameter         No

Fast Response         6

Universal Fast        12

Rate of Rise heat detection as DT1131A

Parameter         No

A1R         1

Fixed temperature heat detection as DT1132A

Parameter         No

BS                         4

126bv/02
FDOOT241-A9

Multisensor Detector with Short Circuit Isolator

(FDB221, FDB222, FDB201, FDB202, FDB299, FDB291, FDB293, DB1101A and SPF600 bases)

Note: - the following modes are approved

1 - Parameter sets for detection when connected to FDnet communication

protocol and collective detector line

Mode 0 - "Neural Fire Detector-Multisensor Detector":

Parameter         No

Robust         2

Balanced         4

Suppression         5

Fast Response         6

High Compensation         7

High Sensitive Fast         9

Super Sensitive        11

Mode 1 - "Heat Detector":

Parameter         No

A1R         1

BR         2

A1S         3

BS         4

Mode 2 - "Smoke Detector":

Parameter         No

Universal         1

Robust         2

Sensitive                 3

Super Sensitive                5

126bv/03

 

Bases
FDB221       Base with stand offs
FDB222       Base without stand offs
FDB291       Base attachment surface
FDB293       Base attachment surface wet
DB720       Detector base
DB721       Detector base with loop contact
DB1151A   Base for Sinteso & AlgoRex systems
FDB251         Base adaptor for Sinteso & AlgoRex systems
FDB295         Base attachment
DB1131A   Base for Analog Plus Fire Detectors   
FDB241         Standard base for special location
FDB201         Detector Base Collective
FDB202         Detector Base Collective, Flat
FDB299         Base Adaptor for Migration Detectors
DB1101     Base for Collective Fire Detectors
SPF600         Detector Base for Sigmasys


 


 

To read the Red Book section introduction click here.

 

< back to results page

< back to search page