Search by Certificate Number

Siemens Switzerland Ltd

Theilerstrasse 1a
CH-6300 Zug
Switzerland

Web: www.siemens.com



Certificate No 531d-(cl-1) to EN 54-7:2000 + A1:2002 + A2:2006, EN 54-17:2005, CEA 4021:2003-07
Certificate No 126bv to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 + A2:2006, EN 54-17:2005, EN 54-29:2015




Product Description LPCB
Ref. No.
OH720

Analogue Addressable Multi Sensor Smoke Detector

(DB720, DB721 bases)

Note:

1)        Meets the requirements of EN 54-7 in the following sensitivities:

1 - Robust 3.5%/m

2 - Sensitive 2.5%/m

531d/01
FDOOT241-A5

Addressable Optical Smoke and Heat Multi-Sensor Detector with Short Circuit Isolator (DB1151A, FDB251, FDB295, FDB221, FDB222, FDB291 and FDB293 Bases)

Notes:

1.        The following modes are approved when used with Sinteso FDnet protocol:

EN 54-29 and EN 54-7 Settings:

Mode 0 - "Neural Fire Detector"

Parameter                 No

Robust                        2

Balanced                4

Suppression                5

Fast Response                6

High Compensation        7

High Sensitive Fast        9

Super Sensitive                11

EN 54-5 Settings:

Mode 1 - "Heat Detector"

Parameter                 No

A1R                        1

BR                        2

A1S                        3

BS                        4

EN 54-7 Settings:

Mode 2 - "Smoke Detector"

Parameter                 No

Universal                1

Robust        2                

Sensitive                3

Super Sensitive                5

2.  The following modes are approved when used with the AlgoRex Interactive protocol:

EN 54-29 and EN 54-7 Settings:

Mode 0 - "Neural Fire Detector"

Parameter                 No

Balanced                4

Suppression                5

Fast Response                6

High Sensitive Fast        9

Super Sensitive                11

EN 54-5 Settings:

Mode 1 - "Heat Detector"

Parameter                 No

A1R                        1

BR                        2

A1S                        3

BS                        4

EN 54-7 Settings:

Mode 2 - "Smoke Detector"

Parameter                 No

Universal                1

Sensitive                3

Super Sensitive                5

3. Refer to manufacturer's documentation A6V10323158 when making changes to interactive protocol and replacing the following detectors.

DOT1151A, DOT1152A replaced by FDOOT241-A5

EN 54-29 and EN 54-7 Settings:

Mode 0 - "Neural Fire Detector - Multisensor Detector"

Parameter                No         legacy setting         

Balanced                4        APS005S, APS006S, APS015S, APS019S,                                         APS009S, APS082S

Suppression                5        APS084S

Fast Response                6        APS007S, APS085S

High Sensitive Fast        9        APS081S

Super Sensitive                11        APS080S

DT1152A replaced by FDOOT241-A5

EN 54-5 Settings:

Mode 1 - "Heat Detector"

Parameter                No        legacy setting

A1R                        1        APS100T

BR                        2        APS105T

A1S                        3        APS103T

BS                        4        APS107T

Smoke detector DO1151A, DO1152A replaced by FDOOT241-A5

EN 54-5 Settings:

Mode 2 - "Smoke detector"

Parameter                No        legacy setting

Universal                 1        APS005S

Sensitive                3        APS006S

Super Sensitive                5        APS007S, APS009S

Smoke detector DO1153A replaced by FDOOT241-A5

EN 54-7 Settings:

Mode 2 - "Smoke detector"

Parameter                No        legacy setting

Super Sensitive                5        APS073SH

126bv/01
FDOOT241-A3

Multisensor Detector with Short Circuit Isolator

(FDB221, FDB222, DB1131A, FDB291, FDB293, FDB295 and FDB241 bases)

Note - the following modes are approved

1 - Parameter sets for detection when connected to FDnet communication

Protocol

EN 54-29 and EN 54-7 Settings:

Mode 0 - "Neural Fire Detector-Multisensor Detector":

Parameter         No

Robust         2

Balanced         4

Suppression         5

Fast Response         6

High Compensation         7

High Sensitive Fast         9

Super Sensitive        11

EN 54-5 Settings:

Mode 1 - "Heat Detector"

Parameter         No

A1R         1

BR         2

A1S         3

BS         4

EN 54-7 Settings:

Mode 2 - "Smoke Detector"

Parameter         No

Universal         1

Robust         2

Sensitive         3

Super Sensitive                5

2 - Parameter sets for detection when connected to AnalogPLUS

communication protocol

Smoke only as DO1131A

Parameter         No

Sensitive         3

Universal Fast         4

Smoke with heat enhancement as DOT1131A

Parameter         No

Fast Response         6

Universal Fast        12

Rate of Rise heat detection as DT1131A

Parameter         No

A1R         1

Fixed temperature heat detection as DT1132A

Parameter         No

BS                         4

126bv/02
FDOOT241-A9

Multisensor Detector with Short Circuit Isolator

(FDB221, FDB222, FDB201, FDB202, FDB299, FDB291, FDB293, FDB295, DB1101A and SPF600 bases)

Note: - the following modes are approved

1 - Parameter sets for detection when connected to FDnet communication protocol and collective detector line

EN 54-29 and EN 54-7 Settings:

Mode 0 - "Neural Fire Detector-Multisensor Detector":

Parameter         No

Robust         2

Balanced         4

Suppression         5

Fast Response         6

High Compensation         7

High Sensitive Fast         9

Super Sensitive        11

EN 54-5 Settings:

Mode 1 - "Heat Detector":

Parameter         No

A1R         1

BR         2

A1S         3

BS         4

EN 54-7 Settings:

Mode 2 - "Smoke Detector":

Parameter         No

Universal         1

Robust         2

Sensitive        3

Super Sensitive                5

126bv/03
OOH740

Analogue Addressable Multisensor Detector with Short Circuit Isolator

(DB720, DB721, DB722, BA720, BA721, DB721D & DB110 bases)

Note: - the following modes are approved

1 - Parameter sets for detection when connected to C-Net detector line

EN 54-29 and EN-54-7 Settings:

Mode 0 - "Neural Fire Detector"

Parameter         No

Robust         2

Balanced         4

Suppression         5

Fast Response         6

High Compensation         7

High Sensitive Fast         9

EN 54-5 Settings:

Mode 1 - "Heat Detector"

Parameter         No

A1R         1

BR         2

A1S         3

BS         4

EN 54-7 Settings:

Mode 2 - "Smoke Detector"

Parameter         No

Universal         1

Robust         2

Sensitive         3

Super Sensitive        5

2 - Parameter sets for detection when connected to collective detector line

Parameter         Resistor value in detector base

Standard Plus         -

Suppression         33 K

High Sensitive Fast         68 K

126bv/04
FDOOT241-A

Multi Sensor Detector with Short Circuit Isolator

(FDB221, FDB222, FDB291, FDB293, FDB295 bases)

Note: - the following modes are approved

1 - Parameter sets for detection when connected to FDnet communication

protocol and collective detector line

EN 54-29 and EN 54-7 Settings:

Mode 0 - "Multisensor Detector":

Parameter         No

Robust         2

Balanced         4

Suppression         5

Fast Response         6

High Compensation         7

High Sensitive Fast         9

EN 54-5 Settings:

Mode 1 - "Heat Detector":

Parameter         No

A1R         1

BR         2

A1S         3

BS         4

EN 54-7 Settings

Mode 2 - "Smoke Detector":

Parameter         No

Universal         1

Robust         2

Sensitive         3

Super Sensitive                5

126bv/05

 

FDB221       Addressable Detector Base
FDB222       Addressable Flat Detector Base
DB1151A    Base for Sinteso & AlgoRex systems
DB1131A    Base for Analog Plus Fire Detectors
FDB251       Base Adaptor for Sinteso & AlgoRex systems
FDB295       Base Attachment Wet
FDB291       Base Attachment for Surface Mount Cable Entry
FDB293       Base Adaptor Humid
FDB241       Base Adaptor for Migration Detectors
FDB201       Detector Base Collective
FDB202       Detector Base Collective, Flat
FDB299       Base Adaptor for Migration Detectors
DB1101A    Base for Collective Fire Detectors
SPF600       Detector Base for Sigmasys

 


 

To read the Red Book section introduction click here.

 

< back to results page