80A, Jalan Megat
Batu Pahat
Johor
83000
Malaysia
Tel: +60167788888
Email: ss@ssfiresecurity.com
Certificate No 548p-(cl-6) to EN 54-2:1997 + A1:2006 & EN 54-4:1997 + A1:2002 + A2:2006
Control and indicating equipment
Product | Description | LPCB Ref. No. |
---|---|---|
SP-200-2/2 | Intelligent 2 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment Incorporating the following units: MB-220/ F7.820.826 Main board SB-220/ F7.820.827 Switch board TB-220/ F7.820.828 Loop interface board PS-220/ F7.820.829b Power supply unit ZP-220/ F7.820.312d Zone indication and intervention board
LC200/ F7.820.1125 Loop board Incorporating as optional modular units: P-9930/ F7.820.913a RS-232 board for configuration P-9901A Printer module kit
7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points |
548p/01 |
SP-IFP8 | Intelligent 8 Loop, 140 Zone Analogue Addressable Control and Indicating Equipment Incorporating the following units: SB-800 Indication board SI-CIFP8 Loop board PB-800 Power board ZP-800 ZCP board KB-800 Keypad board MB-800 Main board MO-800 Mother board
PS-800 Switch Mode Power Supply SP-320-27 SI-9935 Communication Card SI-9935Modbus RS232 ModBus Communication Card SI-9945RP Repeater Card SI-9945A Class A RS485 Network Card SI-9965 Class B CAN Network Card SI-9965A Class A CAN Network Card SI-9904 Printer Interface Card
Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.9.2 Alarm confirmation input from fire routing equipment 7.10.1 Output type A 7.10.2 Output type B 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition
Notes: 1. Scope of approval does not include the operation of the network functionality 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
548p/02 |
SP-102A | 2 Zone Conventional Control and Indicating Equipment Incorporating the following modules: FC-102A/ F7.843.399 Membrane CB-102A/ F2.908.1719 Control board with integrated PSE DB-102A/ F2.908.1722 Display board
Optional modules: CF-102A/ F7.843.421 Membrane
Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fir routing equipment 7.11 Delays to outputs 10 Test condition |
548p/03 |
SP-104A | 4 Zone Conventional Control and Indicating Equipment Incorporating the following modules: FC-104A/ F7.843.400 Membrane CB-104A/ F2.908.1718 Control board with integrated PSE DB-104A/ F2.908.1721 Display board
Optional modules: CF-104A/ F7.843.422 Membrane
Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition |
548p/04 |
SP-108A | 8 Zone Conventional Control and Indicating Equipment Incorporating the following modules: FC-108A/ F7.843.401 Membrane CB-108A/ F2.908.1675 Control board with integrated PSE DB-108A/ F2.908.1720 Display board
Optional modules: CF-108A/ F7.843.423 Membrane
Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition |
548p/05 |
SP-116A | 16 Zone Conventional Control and Indicating Equipment Incorporating the following modules: FC-116A/ F7.843.402 Membrane CB-116A/ F2.908.1724 Control board with integrated PSE DB-116A/ F2.908.1676 Display board XB-116A/ F7.820.1677 Expansion board
Optional modules: CF-116A/ F7.843.424 Membrane
Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition |
548p/06 |
SP-200-2/1 | Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment Incorporating the following units: MB-220/ F7.820.826 Main board SB-220/ F7.820.827 Switch board TB-220/ F7.820.828 Loop interface board PS-220/ F7.820.829b Power supply unit ZP-220/ F7.820.913a Zone indication and intervention board
P-9930/ F7.820.913a RS-232 board for configuration P-9901A Printer module kit LC200/ F7.820.1125 Loop board (for loop expansion)
Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points
Note: can be extended to 2 loop panel by adding LC200 |
548p/08 |
SP-200N-2 | Intelligent 2 loop, 30 Zone Analogue Addressable Control and Indicating Equipment Incorporating the following units: MB-220N Main board PS-220N Power management board OX-220 Terminal board ZP-220 Zone indication and intervention board SB-220 Switch board TB-220N Loop interface board LC200 Loop board PDF-150-27.5 Powered SMPS 100-240V power supply
SI-9930 RS-232 board for configuration SI-9901A Printer module kit SI-9960A CAN network card loop type board SI-9930ModBus RS232 Modbus interface card
7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points
Notes: 1. Scope of approval does not include the operation of the network functionality 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
548p/07 |
SP-200N-1 | Intelligent 2 loop, 30 Zone Analogue Addressable Control and Indicating Equipment Incorporating the following units: MB-220N Main board PS-220N Power management board OX-220 Terminal board ZP-220 Zone indication and intervention board SB-220 Switch board TB-220N Loop interface board PDF-150-27.5 Powered SMPS 100-240V power supply
Incorporating as optional modular units: SI-9930 RS-232 board for configuration SI-9901A Printer module kit SI-9960A CAN network card loop type board SI-9930ModBus RS232 Modbus interface card LC200 Loop board (for loop expansion)
Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable point
Notes: 1. Can be extended to 2-loop panel by adding LC200 2. Scope of approval does not include the operation of the network functionality 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
548p/11 |
To read the Red Book section introduction click here.