Grosvenor Road
Gillingham Business Park
Gillingham
Kent
ME8 0SA
United Kingdom
Tel: +44 (0)1634 260133
•
Fax: +44 (0)1634 260132
Email: info@hochikieurope.com
•
Web: www.hochikieurope.com
Certificate No 164s to EN 54-23: 2010
Certificate No 164t to EN 54-3:2001 + A1:2002 + A2:2006 and EN 54-23:2010
Certificate No 164ae to EN 54-3:2001 + A1:2002 + A2:2006, EN 54-23:2010 & EN 54-17:2005
Product | Description | LPCB Ref. No. |
---|---|---|
CHQ-CB(RED)/WL-15 | Addressable Ceiling VAD (White LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-SB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/01 |
CHQ-CB(WHT)/WL-15 | Addressable Ceiling VAD (White LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-SB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/02 |
CHQ-CB(RED)/WL | Addressable Ceiling VAD (White LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS,YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following category:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/03 |
CHQ-CB(WHT)/WL | Addressable Ceiling VAD (White LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following category:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/04 |
CHQ-CB(RED)/RL | Addressable Ceiling VAD (Red LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-SB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following category:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/05 |
CHQ-CB(WHT)/RL | Addressable Ceiling VAD (Red LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following category:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/06 |
CHQ-CB/WL-15 | Addressable Ceiling VAD (White LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/07 |
CHQ-CB/WL | Addressable Ceiling VAD (White LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following category:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/08 |
CHQ-CB/RL | Addressable Ceiling VAD (Red LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following category:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/09 |
CHQ-CB(RED)/WL-15-HFP | Addressable Ceiling VAD (White LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/01 |
CHQ-CB(WHT)/WL-15-HFP | Addressable Ceiling VAD (White LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/02 |
CHQ-CB(RED)/WL-HFP | Addressable Ceiling VAD (White LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following category:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/03 |
CHQ-CB(WHT)/WL-HFP | Addressable Ceiling VAD (White LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following category:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/04 |
CHQ-CB(RED)/RL-HFP | Addressable Ceiling VAD (Red LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following category:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/05 |
CHQ-CB(WHT)/RL-HFP | Addressable Ceiling VAD (Red LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following category:
- LOL 0 - Synchronization
5. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
6. The ceiling mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit |
164s/06 |
CHQ-WSB2/WL | Addressable Type A/B Wall Sounder (White LED) Beacon (YBO-R/3(RED), YBO-R/SCI(RED) and YBN-R/3(WHT) bases) Notes: 1. The wall mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones. 3. The VAD is Type A when used with any of the above bases and Type B when used with a WS2-WPK weatherproofing kit
Approved tones: 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/01 |
CHQ-WSB2/RL | Addressable Type A/B Wall Sounder (Red LED) Beacon (YBO-R/3(RED), YBO-R/SCI(RED) and YBN-R/3(WHT) bases) Notes: 1. The wall mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones. 3. The VAD is Type A when used with any of the above bases and Type B when used with a WS2-WPK weatherproofing kit
Approved tones: 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/02 |
CHQ-WSB2(WHT)/WL | Addressable Type A/B Wall Sounder (White LED) Beacon (YBO-R/3(WHT) and YBN-R/3(WHT)-SCI bases) Notes: 1. The wall mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones. 3. The VAD is Type A when used with any of the above bases and Type B when used with a WS2-WPK weatherproofing kit
Approved tones: 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/03 |
CHQ-WSB2(WHT)/RL | Addressable Type A/B Wall Sounder (Red LED) Beacon (YBO-R/3(WHT) and YBN-R/3(WHT)-SCI bases) Notes: 1. The wall mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones. 3. The VAD is Type A when used with any of the above bases and Type B when used with a WS2-WPK weatherproofing kit
Approved tones: 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/04 |
YBO-BSB2/WL | Analogue Addressable Type A Base Sounder (White LED) Beacon (YBO-R/3(RED), YBO-R/SCI(RED) and YBN-R/3(WHT) bases) Notes:
- Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones
Approved tones: 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/05 |
YBO-BSB2/RL | Analogue Addressable Type A Base Sounder (Red LED) Beacon (YBO-R/3(RED), YBO-R/SCI(RED) and YBN-R/3(WHT) bases) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones
Approved tones: 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/06 |
YBO-BSB2(WHT)/WL | Analogue Addressable Type A Base Sounder (White LED) Beacon (YBO-R/3(WHT), YBN-R/3(WHT)-SCI Bases) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones
Approved tones: 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/07 |
YBO-BSB2(WHT)/RL | Analogue Addressable Type A Base Sounder (Red LED) Beacon YBO-R/3(WHT) & YBN-R/3(WHT)-SCI Bases Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones
Approved tones: 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/08 |
CHQ-WSB2/WL-HFP | Addressable Type A/B Wall Sounder (White LED) Beacon (YBO-R/3(RED) and YBO-R/SCI(RED) bases) Notes: 1. The wall mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones. 3. The VAD is Type A when used with any of the above bases and Type B when used with a WS2-WPK weatherproofing kit Approved tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/01 |
CHQ-WSB2/RL-HFP | Addressable Type A/B Wall Sounder (Red LED) Beacon (YBO-R/3(RED) and YBO-R/SCI(RED) bases) Notes: 1. The wall mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones. 3. The VAD is Type A when used with any of the above bases and Type B when used with a WS2-WPK weatherproofing kit Approved tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/02 |
CHQ-WSB2(WHT)/WL-HFP | Addressable Type A/B Wall Sounder (White LED) Beacon (YBO-R/3(WHT) and YBN-R/3(WHT)-SCI bases) Notes: 1. The wall mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones. 3. The VAD is Type A when used with any of the above bases and Type B when used with a WS2-WPK weatherproofing kit Approved tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/03 |
CHQ-WSB2(WHT)/RL-HFP | Addressable Type A/B Wall Sounder (Red LED) Beacon (YBO-R/3(WHT), YBN-R/3(WHT)-SCI Bases) Notes: 1. The wall mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones. 3. The VAD is Type A when used with any of the above bases and Type B when used with a WS2-WPK weatherproofing kit Approved tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/04 |
YBO-BSB2(WHT)/WL-HFP | Analogue Addressable Type A Base Sounder (White LED) Beacon (YBO-R/3(WHT), YBN-R/3(WHT)-SCI Bases) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones Approved tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/07 |
YBO-BSB2(WHT)/RL-HFP | Analogue Addressable Type A Base Sounder (Red LED) Beacon (YBO-R/3(WHT), YBN-R/3(WHT)-SCI Bases) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones Approved tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms |
164t/08 |
CHQ-WB/WL |
Intelligent Analogue Addressable Type A Wall VAD (White LED) Notes:
1. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
5. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2
- Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit. |
164s/10 |
CHQ-WB(WHT)/WL | Intelligent Analogue Addressable Type A Wall VAD (White LED)-White Body (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
5. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2
- Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit. |
164s/11 |
CHQ-WB(RED)/WL | Intelligent Analogue Addressable Type A Wall VAD (White LED)-Red Body (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
5. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2
- Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit. |
164s/12 |
CHQ-WB/RL | Intelligent Analogue Addressable Type A Wall VAD (Red LED) (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes
1. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
5. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 6. The Default factory setting is LOL 1, 0.5Hz 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit. |
164s/13 |
CHQ-WB(WHT)/RL | Intelligent Analogue Addressable Type A Wall VAD (Red LED)-White Body (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
5. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 6. The Default factory setting is LOL 1, 0.5Hz 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit. |
164s/14 |
CHQ-WB(RED)/RL | Intelligent Analogue Addressable Type A Wall VAD (Red LED)-Red Body (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes
1. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
5. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 6. The Default factory setting is LOL 1, 0.5Hz 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit. |
164s/15 |
CHQ-WB(WHT)/WL-HFP | Intelligent Analogue Addressable Type A Wall VAD (White LED) - White Body (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
5. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2
- Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit. |
164s/11 |
CHQ-WB(RED)/WL-HFP | Intelligent Analogue Addressable Type A Wall VAD (White LED)-Red Body (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes:
1. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
5. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2
- Synchronization 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit. |
164s/12 |
CHQ-WB(WHT)/RL-HFP | Intelligent Analogue Addressable Type A Wall VAD (Red LED)-White Body (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes
1. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
5. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 6. The Default factory setting is LOL 1, 0.5Hz 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit. |
164s/14 |
CHQ-WB(RED)/RL-HFP | Intelligent Analogue Addressable Type A Wall VAD (Red LED) - Red Body (YBO-R/SCI, YBN-R/3(SCI), YBN-R/3, YBO-BS, YBO-BSB2(RL&WL) & YBO-BSB Bases) Notes
1. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 0 - Synchronization
2. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
3. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization
4. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 1 - Synchronization
5. The Wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories:
- LOL 2 - Synchronization 6. The Default factory setting is LOL 1, 0.5Hz 7. Type B for outdoor use when used in conjunction with a WS2-WPK weatherproofing kit. |
164s/15 |
YBO-BSB2(BLK)/RL | Addressable Type A Base Sounder Beacon (Black Housing, Red LED) YBO-R/3(RED), YBO-R/SCI(RED) and YBN-R/3(WHT), YBO-R/3(WHT) and YBN-R/3(SCI) Bases Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones |
164t/09 |
YBO-BSB2(BLK))/WL | Addressable Type A Base Sounder Beacon (Black Housing, White LED) YBO-R/3(RED), YBO-R/SCI(RED) and YBN-R/3(WHT), YBO-R/3(WHT) and YBN-R/3(SCI) Bases Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category 0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for tones 1 to 51 listed under approved tones |
164t/10 |
YBO-BSB3/RL | Intelligent Analogue Addressable Type A Base Sounder Beacon (Red LED) - Ivory Version (YBV-R/4 base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category O-1.2-2.0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164t/11 |
YBO-BSB3(WHT)/RL | Intelligent Analogue Addressable Type A Base Sounder Beacon (Red LED) - White Version (YBV-R/4(WHT) base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category O-1.2-2.0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164t/11 |
YBO-BSB3(BLK)/RL | Intelligent Analogue Addressable Type A Base Sounder Beacon (Red LED) - Black Version (YBV-R/4(BLK) base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category O-1.2-2.0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164t/11 |
YBO-BSB3(HFP)/RL | Intelligent Analogue Addressable Type A Base Sounder Beacon (Red LED) - White Version (YBV-R/4(WHT) base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category O-1.2-2.0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164t/11 |
YBO-BSB3/WL | Intelligent Analogue Addressable Type A Base Sounder Beacon (White LED) - Ivory Version (YBV-R/4 base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category C-3-2.6 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164t/12 |
YBO-BSB3(WHT)/WL | Intelligent Analogue Addressable Type A Base Sounder Beacon (White LED) - White Version (YBV-R/4(WHT) base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category C-3-2.6 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164t/12 |
YBO-BSB3(BLK)/WL | Intelligent Analogue Addressable Type A Base Sounder Beacon (White LED) - Black Version (YBV-R/4(BLK) base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category C-3-2.6 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164t/12 |
YBO-BSB3(HFP)/WL | Intelligent Analogue Addressable Type A Base Sounder Beacon (White LED) - White Version (YBV-R/4(WHT) base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category C-3-2.6 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164t/12 |
YBO-BSB3/RL(SCI) | Intelligent Analogue Addressable Type A Base Sounder Beacon (Red LED) with Short Circuit Isolator - Ivory Version (YBV-R/4 base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category O-1.2-2.0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164ae/01 |
YBO-BSB3(WHT)/RL-SCI | Intelligent Analogue Addressable Type A Base Sounder Beacon (Red LED) with Short Circuit Isolator - White Version (YBV-R/4(WHT) base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category O-1.2-2.0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164ae/01 |
YBO-BSB3(BLK)/RL-SCI | Intelligent Analogue Addressable Type A Base Sounder Beacon (Red LED) with Short Circuit Isolator - Black Version (YBV-R/4(BLK) base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category O-1.2-2.0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164ae/01 |
YBO-BSB3(HFP)/RL-(SCI) | Intelligent Analogue Addressable Type A Base Sounder Beacon (Red LED) with Short Circuit Isolator - White Version (YBV-R/4(WHT) base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category O-1.2-2.0 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164ae/01 |
YBO-BSB3/WL(SCI) | Intelligent Analogue Addressable Type A Base Sounder Beacon (White LED) with Short Circuit Isolator - Ivory Version (YBV-R/4 base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category C-3-2.6 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164ae/02 |
YBO-BSB3(WHT)/WL-SCI | Intelligent Analogue Addressable Type A Base Sounder Beacon (White LED) with Short Circuit Isolator - White Version (YBV-R/4(WHT) base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category C-3-2.6 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164ae/02 |
YBO-BSB3(BLK)/WL-SCI | Intelligent Analogue Addressable Type A Base Sounder Beacon White LED) with Short Circuit Isolator - Black Version (YBV-R/4(BLK) base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category C-3-2.6 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164ae/02 |
YBO-BSB3(HFP)/WL-(SCI) | Intelligent Analogue Addressable Type A Base Sounder Beacon (White LED) with Short Circuit Isolator - White Version (YBV-R/4(WHT) base) Notes: 1. The ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category C-3-2.6 - Flash rate 0.5Hz - Synchronization 2. Meets the requirements of EN 54-3 for all 56 tones as listed under approved tones Approved Tones 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms / Off : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms / Off : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3500 ms / Off 500 ms 53 - Marine 1000Hz (1s on, 1s off)x7 + (7s on, 1s off) 54 - Whoop 1200 Hz - 500 Hz : 1000ms 55 - Ramp up 150 Hz - 1000 Hz : 10s. 1000 Hz 40s. Ramp down 1000 Hz - 150 Hz: 10s. 56 - 725 Hz Continuous 57 - 725 Hz : 700 ms / Off : 300 ms |
164ae/02 |