Gulf Security Technology Co., Ltd.

No 80 Changjiang East Road
QETDZ
Qinhuangdao
Hebei Province
066004
China

Tel: +86 0335 8502434 • Fax: +86 0335 8502532
Email: sales@carrier.com • Web: www.gst.com.cn


Certificate No 548p to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006




Product Description LPCB
Ref. No.
GST-IFP8

Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment

Incorporating the following units:

SB-800                Indication board

LCIFP8                Loop board

PB-800                Power board

ZP-800                ZCP board

KB-800                Keypad board

MB-800                Main board

MO-800                Mother board

PS-800         Switch Mode Power Supply SP-320-27

Incorporating as optional modular units:

P-9935                USB communication board

P-9935Modbus        RS232 ModBus Communication Card

P-9945RP        Repeater Card

P-9945A        Class A RS485 Network Card

P-9965                Class B CAN Network Card

P-9965A        Class A CAN Network Card

P-9904                 Printer Interface Card

Optional language variants;

GST-IFP8-PT         Portuguese language variant

GST-IFP8-HU         Hungarian language variant

GST-IFP8-FR         French language variant

GST-IFP8-IT         Italian language variant

GST-IFP8-SP         Spanish language variant

GST-IFP8-TK         Turkish language variant

Certified with the following options with requirements from EN54 Part 2:

7.8 Output to fire alarm devices

7.9.1 Output to fire routing equipment

7.9.2 Alarm confirmation input from fire routing equipment

7.10.1 Output type A

7.10.2 Output type B

7.11 Delays to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.13 Alarm counter

8.3 Fault signals from points

9.5 Disablement of each address point

10 Test condition

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

548p/02
GST200-2

Intelligent 2 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment

Incorporating the following units:

MB-220/ F7.820.826         Main board

SB-220/ F7.820.827         Switch board

TB-220/ F7.820.828         Loop interface board

PS-220/ F7.820.829b         Power supply unit

ZP-220/ F7.820.312d         Zone indication and intervention board

LC200/ F7.820.1125         Loop board

Incorporating as optional modular units:

P-9930/ F7.820.913a        RS-232 board for configuration

P-9901A                Printer module kit

Certified with the following options with requirements from EN 54 part 2:

7.8         Output to Fire Alarm Devices

7.10.1         Output to automatic Fire Protection Equipment Type A

7.11         Delays to outputs

8.3         Fault signals from points

9.5         Disablement of addressable points

548p/01
GST102A

2 Zone conventional control and indicating equipment

Incorporating the following modules:

FC-102A/ F7.843.399         Membrane

CB-102A/ F2.908.1719         Control board with integrated PSE

DB-102A/ F2.908.1722         Display board

Optional modules:

GST102A-HK          Traditional Chinese text variant

CF-102A/ F7.843.421        Membrane

Certified with the following options with requirements from EN 54 Part 2:

7.8         Output to fire alarm devices

7.9.1         Output to fire routing equipment

7.11         Delays to outputs

10         Test condition

548p/03
GST104A

4 Zone conventional control and indicating equipment

Incorporating the following modules:

FC-104A/ F7.843.400         Membrane

CB-104A/ F2.908.1718         Control board with integrated PSE

DB-104A/ F2.908.1721         Display board

Optional modules:

GST104A-HK         Traditional Chinese text variant

CF-104A/ F7.843.422        Membrane

Certified with the following options with requirements from EN 54 Part 2:

7.8         Output to fire alarm devices

7.9.1         Output to fire routing equipment

7.11         Delays to outputs

10         Test condition

548p/04
GST108A

8 Zone conventional control and indicating equipment

Incorporating the following modules:

FC-108A/ F7.843.401         Membrane

CB-108A/ F2.908.1675         Control board with integrated PSE

DB-108A/ F2.908.1720         Display board

Optional modules:

GST108A-HK         Traditional Chinese text variant

CF-108A/ F7.843.423        Membrane

Certified with the following options with requirements from EN 54 Part 2:

7.8         Output to fire alarm devices

7.9.1         Output to fire routing equipment

7.11         Delays to outputs

10         Test condition

548p/05
GST116A

16 Zone Conventional Control and Indicating Equipment

Incorporating the following modules:

FC-116A/ F7.843.402                 Membrane

CB-116A/ F2.908.1724                 Control board with integrated PSE

DB-116A/ F2.908.1676                 Display board

XB-116A/ F7.820.1677                 Expansion board

Optional modules:

GST116A-HK                          Traditional Chinese text variant

CF-116A/ F7.843.424                 Membrane

Certified with the following options with requirements from EN 54 Part 2:

7.8                                 Output to fire alarm devices

7.9.1                                 Output to fire routing equipment

7.11                                Delays to outputs

10                                 Test condition

548p/06
GST200N-2

Intelligent 2 loop, 30 zone analogue addressable control and indicating equipment

Incorporating the following units:

MB-220N         Main board

PS-220N        Power management board

OX-220                Terminal board

ZP-220                Zone indication and intervention board

SB-220                Switch board

TB-220N        Loop interface board

LC200                Loop board

PDF-150-27.5         Powered SMPS 100-240V power supply

Incorporating as optional modular units:

P-9930                RS-232 board for configuration

P-9901A         Printer module kit

P-9960A        CAN network card loop type board

P-9930ModBus         RS232 Modbus interface card

Certified with the following options with requirements from EN54 part 2:

7.8 Output to Fire Alarm Devices

7.10.1 Output to automatic Fire Protection Equipment Type A

7.11 Delays to outputs

8.3 Fault signals from points

9.5 Disablement of addressable points

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

548p/07
GST200-2/1

Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment

Incorporating the following units:

MB-220/ F7.820.826                 Main board

SB-220/ F7.820.827                 Switch board

TB-220/ F7.820.828                  Loop interface board

PS-220/ F7.820.829b                  Power supply unit

ZP-220/ F7.820.913a                  Zone indication and intervention board

Incorporating as optional modular units:

P-9930/ F7.820.913a                 RS-232 board for configuration

P-9901A                         Printer module kit

LC200/ F7.820.1125                Loop board (for loop expansion)

Certified with the following options with requirements from EN 54 part 2:

7.8                                 Output to Fire Alarm Devices

7.10.1                                 Output to automatic Fire Protection Equipment Type A

7.11                                 Delays to outputs

8.3                                 Fault signals from points

9.5                                 Disablement of addressable points

Note: can be extended to 2 loop panel by adding LC200

548p/08
GST200-2/1PT

Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment

Incorporating the following units:

MB-220/ F7.820.826                 Main board

SB-220/ F7.820.827                 Switch board

TB-220/ F7.820.828                 Loop interface board

PS-220/ F7.820.829b                 Power supply unit

ZP-220/ F7.820.312d                 Zone indication and intervention board

Incorporating as optional modular units:

P-9930/ F7.820.913a                 RS-232 board for configuration

P-9901A                         Printer module kit

LC200/ F7.820.1125                 Loop board (for loop expansion)

Certified with the following options with requirements from EN 54 part 2:

7.8                                 Output to Fire Alarm Devices

7.10.1                                 Output to automatic Fire Protection Equipment Type A

7.11                                 Delays to outputs

8.3                                 Fault signals from points

9.5                                 Disablement of addressable points

Note: Can be extended to 2-loop panel by adding LC200

548p/09
GST200-2/1HU

Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating

Equipment (Hungarian Varient)

Incorporating the following units:

MB-220/ F7.820.826                         Main board

SB-220/ F7.820.827                         Switch board

TB-220/ F7.820.828                         Loop interface board

PS-220/ F7.820.829b                         Power supply unit

ZP-220/ F7.820.312d                         Zone indication and intervention board

Incorporating as optional modular units:

P-9930/ F7.820.913a                         RS-232 board for configuration

P-9901A                                 Printer module kit

LC200/ F7.820.1125                         Loop board (for loop expansion)

Certified with the following options with requirements from EN 54 part 2:

7.8                                         Output to Fire Alarm Devices

7.10.1                                         Output to automatic Fire Protection Equipment Type A

7.11                                         Delays to outputs

8.3                                         Fault signals from points

9.5                                         Disablement of addressable points

Note: Can be extended to 2-loop panel by adding LC200

548p/10
GST200N-1

Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment

Incorporating the following units:

MB-220N        Main board

PS-220N        Power management board

OX-220                Terminal board

ZP-220                Zone indication and intervention board

SB-220                Switch board

TB-220N        Loop interface board

PDF-150-27.5         Powered SMPS 100-240V power supply

Incorporating as optional modular units:

P-9930                RS-232 board for configuration

P-9901A         Printer module kit

P-9960A        CAN network card loop type board

P-9930ModBus        RS232 Modbus interface card

Optional language variants:

GST200N-PT         Portuguese language variant

GST200N-HU         Hungarian language variant

GST200N-FR         French language variant

GST200N-IT         Italian language variant

GST200N-SP         Spanish language variant

GST200N-TK         Turkish language variant

GST200N-HK         Traditional Chinese language variant

GST200N-RO         Romanian language variant

Certified with the following options with requirements from EN54 part 2:

7.8 Output to Fire Alarm Devices

7.10.1 Output to automatic Fire Protection Equipment Type A

7.11 Delays to outputs

8.3 Fault signals from points

9.5 Disablement of addressable points

Notes:

  1. Can be converted to 2 loops by adding LC200 Loop board
  2. Scope of approval does not include the operation of the network functionality
  3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13
548p/11

 

 


 