Search by Certificate Number

Zeta Alarms Limited

Detection House
72-78 Morfa Road
Swansea
SA1 2EN
United Kingdom

Tel: +44 (0)1792 455175 • Fax: +44 (0)1792 455176
Email: ghassan@zetaalarmsystems.com • Web: www.zetaalarmsystems.com


Certificate No 330w to EN 54-2:1997 +A1:2006 EN 54-4:1997 +A1:2002 +A2:2006




Product Description LPCB
Ref. No.
SMART 6

Smart Connect Multiloop 6 Port, 1-5 Loop Analogue Addressable Control and Indicating Equipment

Incorporating the following modules:

MMP-DISP         Display PCB

MMP-TERM                    Termination PCB

PCB/PSU-UL-15         Power Supply Controller

BLD-400-V030-NNU      uPowerTek Power Supply Unit

SCM-LCM         Loop Card Module

SCM-ACM         Alarm Circuit Module

Optional modules:

SCM-NM         Network Module
SCM-ZMM         Six Way Zone Monitor Module                    

SCM-MIM                       Six Way Multi Input Module

SCM-RM                         Three Way Relay Module

Certified with the following options with requirements from EN 54-2: 1997:

7.8         Output to fire alarm device(s)

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal -Type B

7.12.3         Dependencies on more than one alarm signal -Type C

8.3         Fault signals from points

9.5         Disablement of each address point        

10         Test condition

Notes:

1. Scope of approval does not include the operation of the network functionality.

2. This product approval does not constitute compliance with the fire detection

     and alarm system requirements of EN54-13.

330w/01
SMART6/32

Smart Connect Multiloop 6 Port, 1-5 Loop Analogue Addressable Control and Indicating Equipment with 32 Zone LED

Incorporating the following modules:

MMP-DISP         Display PCB

MMP-TERM         Termination PCB

PPCB/MMP-ZLX32                 Zone LED Expansion PCB

PCB/PSU-UL-15         Power Supply Controller
BLD-400-V030-NNU             uPowerTek Power Supply Unit

SCM-LCM         Loop Card Module

SCM-ACM         Alarm Circuit Module

Optional modules:

SCM-NM         Network Module
SCM-ZMM         Six Way Zone Monitor Module

SCM-MIM        Six Way Multi Input Module

SCM-RM         Three Way Relay Module

Certified with the following options with requirements from EN 54-2: 1997:

7.8         Output to fire alarm device(s)

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal -Type B

7.12.3         Dependencies on more than one alarm signal -Type C

8.3         Fault signals from points

9.5         Disablement of each address point        

10         Test condition

Notes:

1. Scope of approval does not include the operation of the network functionality.

2. This product approval does not constitute compliance with the fire detection
     and alarm system requirements of EN54-13.

330w/02
SMART10/64

Smart Connect Multiloop 10 Port, 1-9 Loop Analogue Addressable Control and Indicating Equipment (Black Enclosure)

Incorporating the following modules:

MMP-DISP         Display PCB

MMP-TERM         Termination PCB
PCB MMP-TERM/EXP        Term Expander - 4 port

PCB/MMP-ZLX64        Zone LED Expansion PCB

PCB/PSU-UL-15            Power Supply Controller
BLD-400-V030-NNU         uPowerTek Power Supply Unit

SCM-LCM            Loop Card Module

SCM-ACM            Alarm Circuit Module

Optional modules:

SCM-NM                      Network Module

SCM-ZMM         Six Way Zone Monitor Module

SCM-MIM         Six Way Multi Input Module

SCM-RM         Three Way Relay Module

Certified with the following options with requirements from EN 54-2: 1997:

7.8         Output to fire alarm device(s)

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal -Type B

7.12.3         Dependencies on more than one alarm signal -Type C

8.3         Fault signals from points

9.5         Disablement of each address point        

10         Test condition

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and  

     alarm system requirements of EN54-13.

330w/03
SMART10/9/64

Smart Connect Multiloop 10 Port, 1-9 Loop Analogue Addressable Control and Indicating Equipment with Printer

Incorporating the following modules:

MMP-DISP         Display PCB

MMP-TERM         Termination PCB

PCB MMP-TERM/EXP        Term Expander - 4 port

PCB/MMP-ZLX64        Zone LED Expansion PCB (64 zones)

PCB/PSU-UL-15                Power Supply Controller (Charger PCB)

BLD-400-V030-NNU                uPowerTek Power Supply Unit (Third Party)

SCM-LCM            Loop Card Module

SCM-ACM            Alarm Circuit Module

Optional modules:
SCM-NM           Network Module
SCM-ZMM           Six Way Zone Monitor Module                    

SCM-MIM        Six Way Multi Input Module

SCM-RM        Three Way Relay Module

SCM-PM                           Printer Module

Certified with the following options with requirements from EN 54-2: 1997:

7.8         Output to fire alarm device(s)

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal -Type B

7.12.3         Dependencies on more than one alarm signal -Type C

8.3         Fault signals from points

9.5         Disablement of each address point        

10         Test condition

Notes:

1. Scope of approval does not include the operation of the network functionality.

2. This product approval does not constitute compliance with the fire detection

and alarm system requirements of EN54-13.

330w/04
SMART26/64

Smart Connect Multiloop 26 port, 1-16 Loop Analogue Addressable and Conventional Control and Indicating Equipment

Incorporating the following modules:

MMP-DISP         Display PCB

MMP-TERM         Termination PCB
MMP-TERM/EXP        5 x Term Expander - 4 port

PCB/MMP-ZLX64        Zone LED Expansion PCB

PCB/PSU-UL-15         Power Supply Controller

BLD-400-V030-NNU                uPowerTek Power Supply Unit

SCM-LCM            Loop Card Module

SCM-ACM            Alarm Circuit Module

SCM-ZMM         Six Way Zone Monitor Module              
      

Optional modules:

SCM-NM                Network Module

SCM-MIM        Six Way Multi Input Module

SCM-RM        Three Way Relay Module

Certified with the following options with requirements from EN 54-2: 1997:

7.8         Output to fire alarm device(s)

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal -Type B

7.12.3         Dependencies on more than one alarm signal -Type C

8.3         Fault signals from points

9.5         Disablement of each address point        

10         Test condition

Notes:

1. Scope of approval does not include the operation of the network functionality.

2. This product approval does not constitute compliance with the fire detection

     and alarm system requirements of EN54-13.

330w/05
SMART26/P/64

Smart Connect Multiloop 26 port, 1-16 Loop Analogue Addressable and Conventional Control and Indicting Equipment with Printer

Incorporating the following modules:

MMP-DISP         Display PCB

MMP-TERM         Termination PCB

MMP-TERM/EXP        5 x Term Expander - 4 port

PCB/MMP-ZLX64        Zone LED Expansion PCB

PCB/PSU-UL-15        Power Supply Controller  

BLD-400-V030-NNU        uPowerTek Power Supply Unit

SCM-LCM         Loop Card Module

SCM-ACM        Alarm Circuit Module
SCM-ZMM        Six Way Zone Monitor Module                    

Optional modules:

SCM-NM                 Network Module

SCM-MIM        Six Way Multi Input Module

SCM-RM        Three Way Relay Module

SCM-PM                Printer Module

Certified with the following options with requirements from EN 54-2: 1997:

7.8         Output to fire alarm device(s)

7.11         Delays to outputs

7.12.2         Dependencies on more than one alarm signal -Type B

7.12.3         Dependencies on more than one alarm signal -Type C

8.3         Fault signals from points

9.5         Disablement of each address point        

10         Test condition

Notes:

1. Scope of approval does not include the operation of the network functionality.

2. This product approval does not constitute compliance with the fire detection

and alarm system requirements of EN54-13.

330w/06
SMART/REP

Smart Connect Multiloop LCD repeater

Incorporating the following modules:

MMP-DISP         Display PCB

MMP-REP_COM        Repeater communication PCB

Note:

1. Compatible with panels SMART6, SMART6/32, SMART10/64, SMART10/P/64, SMART26/64 & SMART26/P/64.

330w/R01

 


 


 

To read the Red Book section introduction click here.

 

< back to results page

< back to search page