Zone d’activitiés La Pièce 16
CH-1180
Rolle
Switzerland
Tel: +41 44 943 4424
•
Fax: +41 44 943 4399
Email: sse.marketing@systemsensor.com
•
Web: www.systemsensoreurope.com
Certificate No 166h-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006
Certificate No 166j-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Certificate No 166t-(cl-2) to EN 54-23:2010
Certificate No 166m-(cl-2) to EN 54-17: 2005 & EN 54-23:2010
Certificate No 166p-(cl-2) to EN 54-3:2001 + A1:2002 + A2:2006 and EN 54-3:2010
Certificate No 166r-(cl-2) to EN 54-3:2001 + A1:2002 + A2:2006, EN 54-17:2005 & EN 54-23:2010
Certificate No 166s-(cl-2) to EN 54-3:2001 + A1:2002 + A2:2006 & EN 54-23:2010
Audible Warning Devices
Product | Description | LPCB Ref. No. |
---|---|---|
WSO-xx-Nyy | Analogue addressable Type A/B wall mounted sounder (B501AP-cc, Bcc, Wcc bases) Notes: 1. xx indicates body colour. PR=Red, PP=Pure White 2. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 3. Meets the requirements of EN54-3 for all output levels at voltage range 15-32VDC and tones: 1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz. 4. Approved as Type B only when used with Wcc base. |
166h/01 |
WSS-xx-Nyy | Analogue addressable Type A/B wall mounted sounder/strobe (B501AP-cc, Bcc, Wcc bases) Notes: 1. xx indicates body/lens colour. PR=Red/Red, PA=Amber/Amber, PC=Clear/Clear 2. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 3. Meets the requirements of EN54-3 for all output levels at voltage range 15-32VDC and tones: 1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz. 4. Certification excludes the strobe function. 5. Approved as Type B only when used with Wcc base. |
166h/02 |
BSO-xx-Nyy | Analogue addressable Type A integrated detector base sounder (B501AP-cc, Bcc and Wcc bases) Notes: 1. xx indicates body colour. PP=Pure White, DD=Detector White 2. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 3. Meets the requirements of EN54-3 for all output levels at voltage range 15-32VDC and tones: 1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz. |
166h/03 |
BSS-xx-Nyy | Analogue addressable Type A integrated detector base sounder/strobe (B501AP-cc, Bcc and Wcc bases) Notes: 1. xx indicates body/lens colour. PR=Pure White/Red, PA=Pure White/Amber, PC=Pure White/Clear, DR=Detector White/Red, DA=Detector White/Amber, DC=Detector White/Clear 2. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 3. Meets the requirements of EN54-3 for all output levels at voltage range 15-32VDC and tones: 1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz. 4. Certification excludes the strobe function. |
166h/04 |
WSO-xx-Iyy | Analogue addressableType A/B wall mounted sounder with short circuit isolator (B501AP-cc, Bcc bases, and Wcc bases) Notes: 1. xx indicates body colour. PR=Red, PP=Pure White 2. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones: 1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz. 4. Approved as Type B only when used with Wcc base. |
166j/01 |
WSS-xx-Iyy | Analogue addressable Type A/B wall mounted sounder/strobe with short circuit isolator (B501AP-cc, Bcc bases, and Wcc bases) Notes: 1. xx indicates body/lens colour. PR=Red/Red, PA=Amber/Amber, PC=Clear/Clear 2. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones: 1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz. 4. Certification excludes the strobe function. 5. Approved as Type B only when used with Wcc base. |
166j/02 |
BSO-xx-Iyy | Analogue addressable Type A integrated detector base sounder with short circuit isolator (B501AP-cc, Bcc and Wcc bases) Notes: 1. xx indicates body colour. PP=Pure White, DD=Detector White 2. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones: 1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz. |
166j/03 |
BSS-xx-Iyy | Analogue addressable Type A integrated detector base sounder/strobe with short circuit isolator (B501AP-cc, Bcc and Wcc bases) Notes: 1. xx indicates body/lens colour. PR=Pure White/Red, PA=Pure White/Amber, PC=Pure White/Clear, DR=Detector White/Red, DA=Detector White/Amber, DC=Detector White/Clear 2. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones: 1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz. 4. Certification excludes the strobe function. |
166j/04 |
WST-xC-Nyy | Analogue addressable wall mounted LED strobe (B501AP base) Notes: 1. The wall mounted VAD meets the requirements of EN 54-23: 2010
for the following category (light pattern details):
- Synchronization |
166t/01 |
WST-PC-I00 | Analogue addressable wall mounted LED strobe with short circuit isolator (B501AP base) Notes: 1. The wall mounted VAD meets the requirements of EN 54-23: 2010
for the following category (light pattern details):
- Synchronization |
166m/01 |
WSS-xC-Iyy | Analogue Addressable Wall Mounted Sounder / LED Strobe with Short Circuit Isolator (B501AP base) Notes: 1. The wall mounted VAD meets the requirements of EN 54-23: 2010 for the following category (light pattern details): - Category O - Open Class - Flash rate 1Hz - Synchronization 2. x indicates body colour. D=Detector White, P=Pure White 3. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 4. Type A with Bcc deep back box, Type B with Wcc deep back box 5. Meets the requirements of EN54-3: 2001 at the following tones: 1) Alternating 525/440, 2Hz (100ms/400ms); 2) Alternating 800/922, 1Hz; 3) Alternating 800/922, 2Hz; 4) Alternating 2400/2900, 3Hz; 5) Alternating 2500/3100, 2Hz; 6) Alternating 988/645, 2Hz; 7) Continuous 630Hz; 8) Continuous 922Hz; 9) Continuous 1200Hz; 10) Continuous 2810Hz; 11) Sweep 150-1000Hz, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) Intermittent 420Hz, 0.625s on, 0.625 sec off; 13) Sweep 500-1200Hz, 0.25 sec off, 3.75 sec on; 14) Intermittent 630, 3.33Hz, 150ms on, 150ms off; 15) Intermittent 922, 0.8Hz 0.25s on, 1s off; 16) Intermittent 922, 0.5Hz 1s on, 1s off; 17) Intermittent 2810, 1Hz; 18) Intermittent 922, 1Hz 500ms on, 500ms off; 19) Intermittent 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) Continuous 800Hz; 21) Sweep 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) Sweep 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) Sweep 2400 - 2850, 7Hz; 24) Sweep 500 - 1200Hz, (0.5s off, 3.5s on); 25) Sweep 800 - 970, 50Hz; 26) Sweep 800 - 970, 7Hz; 27) Sweep 800 - 970, 1Hz; 28) Sweep 2400 - 2850, 50Hz; 29) Sweep 500 - 1000, 7Hz; 30) Sweep 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) Sweep 800 - 1000, 2Hz; 32) Sweep 2400 - 2850, 1Hz |
166r/01 |
VAD-PC-N## | Analogue Addressable High Output Beacon (B501AP base) Notes: 1. The ceiling / wall mounted VAD meets the requirements of EN 54-23: 2010 for the following categories (light pattern details): - Category C: C-3-5.1, C-6-5.1, C-9-5.1 - Category W: W-2.4-2.76 - Flash rate 0.5Hz - Synchronization 2. Type A indoor use with B501AP only, Type B outdoor use with B501AP and WRR or WPW 3. ## indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) |
166t/02 |
VAD-PC-I## | Analogue Addressable High Output Beacon with Short Circuit Isolator (B501AP base) Notes:
2. Type A indoor use with B501AP only, Type B outdoor use with B501AP and WRR or WPW 3. ## indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) |
166m/02 |
DSS-xC-Iyy | Analogue Addressable Type A Integrated Detector Base Sounder/Beacon with Short Circuit Isolator (B501AP base) Notes: 1. The wall mounted VAD meets the requirements of EN 54-23: 2010 for the following category (light pattern details): - Category O - Open Class - Flash rate 1Hz - Synchronization 2. x indicates body colour. D=Detector White, P=Pure White 3. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 4. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones: 1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz. |
166r/02 |
WSS-xC-Nyy |
Analogue Addressable Wall Mounted Sounder / LED Strobe Notes: 1. The wall mounted VAD meets the requirements of EN 54-23: 2010 for the following category (light pattern details): - Category O - Open Class - Flash rate 1Hz - Synchronization 2. x indicates body colour. D=Detector White, P=Pure White 3. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 4. Type A with Bcc deep back box, Type B with Wcc deep back box 5. Meets the requirements of EN54-3: 2001 at the following tones: 1) Alternating 525/440, 2Hz (100ms/400ms); 2) Alternating 800/922, 1Hz; 3) Alternating 800/922, 2Hz; 4) Alternating 2400/2900, 3Hz; 5) Alternating 2500/3100, 2Hz; 6) Alternating 988/645, 2Hz; 7) Continuous 630Hz; 8) Continuous 922Hz; 9) Continuous 1200Hz; 10) Continuous 2810Hz; 11) Sweep 150-1000Hz, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) Intermittent 420Hz, 0.625s on, 0.625 sec off; 13) Sweep 500-1200Hz, 0.25 sec off, 3.75 sec on; 14) Intermittent 630, 3.33Hz, 150ms on, 150ms off; 15) Intermittent 922, 0.8Hz 0.25s on, 1s off; 16) Intermittent 922, 0.5Hz 1s on, 1s off; 17) Intermittent 2810, 1Hz; 18) Intermittent 922, 1Hz 500ms on, 500ms off; 19) Intermittent 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) Continuous 800Hz; 21) Sweep 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) Sweep 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) Sweep 2400 - 2850, 7Hz; 24) Sweep 500 - 1200Hz, (0.5s off, 3.5s on); 25) Sweep 800 - 970, 50Hz; 26) Sweep 800 - 970, 7Hz; 27) Sweep 800 - 970, 1Hz; 28) Sweep 2400 - 2850, 50Hz; 29) Sweep 500 - 1000, 7Hz; 30) Sweep 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) Sweep 800 - 1000, 2Hz; 32) Sweep 2400 - 2850, 1Hz |
166s/01 |
DSS-xC-Nyy | Analogue Addressable Type A Integrated Detector Base Sounder/Beacon (B501AP base) Notes: 1. The wall mounted VAD meets the requirements of EN 54-23: 2010 for the following category (light pattern details): - Category O - Open Class - Flash rate 1Hz - Synchronization 2. x indicates body colour, D=Detector White, P=Pure White 3. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 4. Meets the requirements of EN54-3 for all output levels at voltage range 15-32VDC and tones: 1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz |
166s/02 |
BGL-xC-Ixx | Addressable Type A Detector Base Strobe Notes: 1. The Ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category rating C-3-8.5 - Synchronization - Flash rate 0.5Hz - Red LED - Clear lens 2. x indicates body colour. D=Detector White, P=Pure White 3. xx indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) |
166m/03 |
BRH-xC-Ixx | Addressable Type A Detector Base Sounder Strobe Notes: 1. x indicates body colour. Detector White, P=Pure White 2. xx indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 3. Meets the requirements of EN 54-3:2001 for the following tones: Tone 1 - Alternating 525 / 440Hz in 100ms/400ms Tone 2 - Alternating 800 / 922Hz for 1Hz Tone 3 - Alternating 800 / 922Hz for 2Hz Tone 4 - Alternating 2400 / 2900Hz for 3Hz Tone 5 - Alternating 2500 / 3100Hz for 2Hz Tone 6 - Alternating 988 / 645Hz for 2Hz Tone 7 - Continuous 630Hz Tone 8 - Continuous 922Hz Tone 9 - Continuous 1200Hz Tone 10 - Continuous 2810Hz Tone 11 - Sweep 150-1000-500Hz Rising from 500Hz to 1000Hz in 10s, Hold 100Hz for 40s Falling from 100Hz to 500Hz in 10s, Hold 500Hz for 20s Tone 12 - Intermittent 420Hz for 150ms on, 150ms off Tone 13 - Sweep 500-1200Hz Rising from 500Hz to 1200Hz in 0.25s, then 3.75s off Tone 14 - Intermittent 630Hz for 150ms on, 150ms off Tone 15 - Intermittent 922Hz for 0.25s on, 1s off Tone 16 - Intermittent 922Hz for 1s on, 1s off Tone 17 - Intermittent 2810Hz for 1Hz Tone 18 - Intermittent 922Hz for 500ms on, 500ms off Tone 19 - Intermittent 950Hz for 500ms on, 500ms off. Repeat 3 times then 1.5s off Tone 20 - Continuous 800Hz Tone 21 - Sweep 400-1200Hz Rising from 400Hz to 1200Hz in 500ms, then 500ms off. Repeat 3 times then 1.5s off Tone 22 - Sweep 1200-500Hz Falling from 1200Hz to 500Hz in 1000ms, 10ms off Tone 23 - Sweep 2400-2850Hz for 7Hz Tone 24 - Sweep 500-1200Hz Rising from 500Hz to 1200Hs in 0.5s, then 3.5s off Tone 25 - Sweep 800-970Hz for 50Hz Tone 26 - Sweep 800-970Hz for 7Hz Tone 27 - Sweep 800-970Hz for 1Hz Tone 28 - Sweep 2400-2850Hz for 50Hz Tone 29 - Sweep 500-1000Hz for 7Hz Tone 30 - Sweep 500-1200-500Hz Rising from 500Hz to 1200Hz in 1s, Hold 1200Hz for 4s Falling from 1200Hz to 500Hz in 1s Tone 31 - Sweep 800-1000Hz for 2Hz Tone 32 - Sweep 2400-2850Hz for 1Hz 4. The Ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category ratings High C-3-15, Low C-3-11 & O-1-4 - Synchronization - Flash rate 0.5Hz & 1Hz - Red LED - Clear lens |
166r/03 |
BRS-PC-Ixx | Addressable Type A Detector Base Sounder Strobe Notes: 1. P indicates body colour. P=Pure White 2. xx indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol) 3. Meets the requirements of EN 54-3:2001 for the following tones: Tone 1 - Alternating 525 / 440Hz in 100ms/400ms Tone 2 - Alternating 800 / 922Hz for 1Hz Tone 3 - Alternating 800 / 922Hz for 2Hz Tone 4 - Alternating 2400 / 2900Hz for 3Hz Tone 5 - Alternating 2500 / 3100Hz for 2Hz Tone 6 - Alternating 988 / 645Hz for 2Hz Tone 7 - Continuous 630Hz Tone 8 - Continuous 922Hz Tone 9 - Continuous 1200Hz Tone 10 - Continuous 2810Hz Tone 11 - Sweep 150-1000-500Hz Rising from 500Hz to 1000Hz in 10s, Hold 100Hz for 40s Falling from 100Hz to 500Hz in 10s, Hold 500Hz for 20s Tone 12 - Intermittent 420Hz for 150ms on, 150ms off Tone 13 - Sweep 500-1200Hz Rising from 500Hz to 1200Hz in 0.25s, then 3.75s off Tone 14 - Intermittent 630Hz for 150ms on, 150ms off Tone 15 - Intermittent 922Hz for 0.25s on, 1s off Tone 16 - Intermittent 922Hz for 1s on, 1s off Tone 17 - Intermittent 2810Hz for 1Hz Tone 18 - Intermittent 922Hz for 500ms on, 500ms off Tone 19 - Intermittent 950Hz for 500ms on, 500ms off. Repeat 3 times then 1.5s off Tone 20 - Continuous 800Hz Tone 21 - Sweep 400-1200Hz Rising from 400Hz to 1200Hz in 500ms, then 500ms off. Repeat 3 times then 1.5s off Tone 22 - Sweep 1200-500Hz Falling from 1200Hz to 500Hz in 1000ms, 10ms off Tone 23 - Sweep 2400-2850Hz for 7Hz Tone 24 - Sweep 500-1200Hz Rising from 500Hz to 1200Hs in 0.5s, then 3.5s off Tone 25 - Sweep 800-970Hz for 50Hz Tone 26 - Sweep 800-970Hz for 7Hz Tone 27 - Sweep 800-970Hz for 1Hz Tone 28 - Sweep 2400-2850Hz for 50Hz Tone 29 - Sweep 500-1000Hz for 7Hz Tone 30 - Sweep 500-1200-500Hz Rising from 500Hz to 1200Hz in 1s, Hold 1200Hz for 4s Falling from 1200Hz to 500Hz in 1s Tone 31 - Sweep 800-1000Hz for 2Hz Tone 32 - Sweep 2400-2850Hz for 1Hz 4. The Ceiling mounted VAD meets the requirements of EN 54-23:2010 for the following: - Category ratings C-3-8.5 & O-1-3 - Synchronization - Flash rate 0.5Hz & 1Hz - Red LED - Clear lens |
166r/04 |
Bases / Ancillaries