Zone d’activitiés La Pièce 16
CH-1180
Rolle
Switzerland
Tel: +41 44 943 4424
•
Fax: +41 44 943 4399
Email: sse.marketing@systemsensor.com
•
Web: www.systemsensoreurope.com
Certificate No 199p-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003
Certificate No 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A1: 2006 & CEA 4021: 2003
Certificate No 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005
Multi-criteria Detectors
Product | Description | LPCB Ref. No. |
---|---|---|
22051TLEI | Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: - Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R |
199aa/01 |
22051TEI | Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: - Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R |
199aa/02 |
ECO1002ABL | Conventional Photo-Thermal Detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases) Note : Meets the requirements of EN54:5-2000 at class A1R and EN54:7:2000 at pre-set sensitivity |
199p/08 |
ECO1002 | Conventional Photo-Thermal Detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD, ECO1000BREL12L, ECO1000BREL12NL and ECO1000BREL24L bases) Note: Meets the requirements of EN 54-5: 2000 at Class A1R and EN 54-7: 2000 at pre-set sensitivity |
199p/01 |
2351TEM | Conventional optical/thermal detector (B401, B401DG, B401R, B401SD, & B401RSD bases) Note: Meets the requirements of EN54-5:2000 at class A1R and EN54-7:2000 at 'High' 'Medium' and 'Low' sensitivity settings. |
199p/03 |
Vision 2020PT | Conventional photo thermal detector (2020B, 2020DB, 2020BSD and 2020DBSD bases) |
199p/04 |
22051TLE | Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: Certified at the following settings: - Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R |
199p/06 |
22051TE | Analogue addressable photo-thermal multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: Certified at the following settings: - Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R |
199p/07 |
2251CTLE-xx-yy | Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal and IR sensors (B501, B501AP, B501DG, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1.) xx = (Range 0-99) ~ indicates the communication software protocol 2.) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 3.) Certified at the following settings: - Normal Mode: Alarm Levels 1 to 5 (Multi-criteria) EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R
Nuisance Environment Applications: Application 0, Alarm Level 4 EN54-7, LPS1279 & CEA 4021 Application 1, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021 Application 2, Alarm Level 4 or 5 EN54-5 Class A1R, EN54-7 & CEA 4021 Application 3, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021 Application 4, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021 Application 5, Alarm Level 5 EN54-7 & CEA 4021 Application 6, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021 Application 7, Alarm Level 5 EN54-5 Class A1R, LPS1279 and CEA 4021 |
199t/01 |
Bases:
To read the Red Book section introduction click here.