Certificate No 176b-(cl-1) to EN 54-2: 1997+A1: 2006 and EN 54-4: 1997+A1: 2002+A2: 2006
Certificate No 810a-(cl-4) to EN 54-2: 1997+A1: 2006 and EN 54-4: 1997+A1: 2002+A2: 2006
Product | Description | LPCB Ref. No. |
---|---|---|
FXP502/X | Two Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo Protocol, Metal housing
Incorporating the following units:
SPF0706000 Switch Mode Power supply board SPF0501201 XFP Apollo 2 Loop, Main motherboard SPF0501200 Display board "Keypad Display"
Certified with the following options with requirements from EN 54-2:1997
7.8 Output to fire alarm device(s) 7.11 Delays to the auctioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. |
176b/02 |
FXP501/X | One Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo Protocol, Metal housing
Incorporating the following units:
SPF0706000 Switch Mode Power supply board SPF0501211 XFP Apollo 1 Loop, Main motherboard SPF0501200 Display board "Keypad Display"
Certified with the following options with requirements from EN 54-2:1997
7.8 Output to fire alarm device(s) 7.11 Delays to the auctioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. |
176b/04 |
FXP501E/X | One Loop, 16 Zone Analogue addressable control and indicating equipment using Apollo protocol, Plastic housing
Incorporating the following units:
SPF0702480 Switch Mode Power supply board SPF0501101 XFP Apollo 1 Loop, Main motherboard
Certified with the following options with requirements from EN 54-2:1997
7.8 Output to fire alarm device(s) 7.11 Delays to the auctioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. |
176b/06 |
FCFP2N | Two zone conventional control and indicating equipment
Incorporating the units:
SPF0702480 Switch mode power supply unit board SPF0724851 2 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition |
176b/07 |
FCFP4N | Four zone conventional control and indicating equipment
Incorporating the units:
SPF0702480 Switch mode power supply unit board SPF0724853 4 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition |
176b/08 |
FCFP8N | Eight zone conventional control and indicating equipment
Incorporating the units:
SPF0702480 Switch mode power supply unit board SPF0724855 8 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition |
176b/09 |
FSDG2 / FSDG4 | Dualguard+ 2 and 4 Zone Conventional Control and Indicating Equipment
FSDG2 Incorporating as modular units: TPC A01-E2 2 zone main PCB applicable on 2 zone CIE only TPC A02 LED display PCB PSM1.5-24 Power supply 1.5A rated
Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.12.1 Dependency on more than one alarm signal type A 10 Test condition
FSDG4 Incorporating as modular units: TPC A01-E4 4 zone main PCB applicable on 4 zone CIE only TPC A02 LED display PCB PSM1.5-24 Power supply 1.5A rated
Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.12.1 Dependency on more than one alarm signal type A 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. |
810a/03 |
FSDG8 / FSDG12 | Dualguard+ 8 and 12 Zone Conventional Control and Indicating Equipment
FSDG8 8 Zone Conventional Control and Indicating Equipment Incorporating as modular units: TPCA01-X4 4 Zone Main PCB TPCA03 Display Board TPCA04-H High Spec 4 Zone Extension Board PSM3.0-24 Power Supply
Incorporating as optional module: TPCA05 Communications Board
FSDG12 12 Zone Conventional Control and Indicating Equipment Incorporating as modular units: TPCA01-X4 4 Zone Main PCB TPCA03 Display Board TPCA04-S Standard 4 Zone Extension Board TPCA04-H High Spec 4 Zone Extension Board PSM3.0-24 Power Supply
Incorporating as optional module: TPCA05 Communications Board
Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.1 Dependency on more than one alarm signal type A 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 10 Test condition Note: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. |
810a/04 |