Certificate No 378a-(cl-3) to EN54-2: 1997 + A1: 2002 & EN54-4: 1997 + A1: 2002 + A2: 2006
Product | Description | LPCB Ref. No. |
---|---|---|
JXD01020 | JSB 1-2 Loop Analogue Addressable Control and Indicating Equipment
Incorporating the following modules: EFXD05001 xDetect Loop Card 1 Loop Protocol 800 (x2 Cards) EFXD05082 xDetect CIE Backplane Small Enclosure EFXD05053 xDetect CIE Int. Single PSE backplane EFXD05080 xDetect CIE Panel Gateway Card EFXD05030 xDetect Programmable IO Card EFXD05020 xDetect Sounder Circuit Card 2 Outputs 36-A780 xDetect HMI 26-A470 xDetect HMI Screen Module EFXD05051 xDetect CIE Int. Power Supply 150W
Incorporating the following optional modules: EFXD05040 xDetect Network Card Mechanical optional modules: EFXD05091 xDetect CIE Door Small HMI Only
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.2 Outputs to fire protection equipment - Output type B 7.10.3 Outputs to fire protection equipment - Output type C 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm Counter 8.3 Fault signals from points 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality 2. This product approval does not constitute compliance with the fire detection and alarm system requirements of EN54-13. |
378q/01 |
JXD01040 | JSB 1-4 Loop Analogue Addressable Control and Indicating Equipment
Incorporating the following modules: EFXD05001 xDetect Loop Card 1 Loop Protocol 800 (x4 Cards) EFXD05081 xDetect CIE Backplane Large Enclosure EFXD05052 xDetect CIE Int. Dual PSE backplane EFXD05080 xDetect CIE Panel Gateway Card
EFXD05030 xDetect Programmable IO Card 36-A780 xDetect HMI 26-A470 xDetect HMI Screen Module EFXD05051 xDetect CIE Int. Power Supply 150W
Incorporating the following optional modules: EFXD05040 xDetect Network Card Mechanical optional modules: EFXD05092 xDetect CIE Door Large HMI Only
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment - Output type A 7.10.2 Outputs to fire protection equipment - Output type B 7.10.3 Outputs to fire protection equipment - Output type C 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm Counter 8.3 Fault signals from points 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality 2. This product approval does not constitute compliance with the fire detection and alarm system requirements of EN54-13. |
378q/02 |