Honeywell Life Safety Systems
Charles Avenue
Burgess Hill
West Sussex
RH15 9UF
United Kingdom
Tel: +44 1444 230 300
•
Fax: +44 1444 230 888
Email: sales@morleyias.co.uk
Certificate No 154g to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Product | Description | LPCB Ref. No. |
---|---|---|
FLS2-8 2 Zone | 002-475-122 Language region 1, light grey 002-489-122 Language region 1, light grey, English manual 002-475-222 Language region 2, light grey 002-489-222 Language region 2, light grey, English manual Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition |
154g/06 |
FLS2-8 4 Zone | 002-475-142 Language region 1, light grey 002-489-142 Language region 1, light grey, English manual 002-475-242 Language region 2, light grey 002-489-242 Language region 2, light grey, English manual Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition |
154g/07 |
FLS2-8 8 Zone | 002-475-182 Language region 1, light grey 002-489-182 Language region 1, light grey, English manual 002-475-282 Language region 2, light grey 002-489-282 Language region 2, light grey, English manual
Incorporating the following units: 020-747 8-way relay kit 020-772 4-way monitored sounder kit Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition |
154g/08 |
To read the Red Book section introduction click here.