Search by Certificate Number

Sterling Safety Systems

Unit B12a, Holly Farm Business Park
Honiley
Warwickshire
CV8 1NP
United Kingdom

Tel: +44(0)1926485282 • Fax: +44(0)1926485090
Email: info@sterlingsafety.co.uk • Web: www.sterlingsafety.co.uk


Certificate No 928c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003
Certificate No 928f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003


Multi-Sensor Detectors

Product Description LPCB
Ref. No.
HFI-MA-05

Addressable Multi-Criteria Detector with Short-Circuit Isolator (HFI-DMBS-05 Base)

Notes:

1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following

settings:

Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response

Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response

Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response

Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:

Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings:

Optical only level 1 - High

Optical only level 2

Optical only level 3

Optical only level 4 - Low

928c/02
HFI-MAE-05

Addressable Photo & Class A1R Heat Detector (HFI-DMBS-05 Base)

Notes:        

1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following

settings:

Multi criteria level 1 (most sensitive) - Thermally enhanced smoke detection

with Class A1 heat response

Multi criteria level 2 - Thermally enhanced smoke detection with Class A1 heat

response

Multi criteria level 3 - Thermally enhanced smoke detection with Class A1 heat

response

Multi criteria level 4 (least sensitive) - Thermally enhanced smoke detection

with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:

Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings:

Optical only - level 1 - High sensitivity

Optical only - level 2

Optical only - level 3

Optical only - level 4 - Low sensitivity

928f/02
HFW-MA-05

Wireless Libra Addressable Multicriteria Detector (WAB100 Base)

Notes:

1.   Meets the requirements of EN 54-5 for Class A1R

2.   Meets the requirements of EN 54-7 at the following sensitivity settings:

Level 1 - High

Level 2 - Normal

Level 3 - Low

3.   The device must be used with the following battery type only:

      CR123A (3 Vdc) - Primary and Secondary Battery

928m/02

 

Bases
HFI-UB-01    Universal adaptor base
HFI-DUB-01    Deep adaptor base
HFI-DMB-01    Vega adaptor base
HFI-DDB-01    Vega deep adaptor base
HFI-UBS-01    Universal adaptor base with shorting clip
HFI-DUBS-01    Deep adaptor base with shorting clip
HFI-DMBS-01    Vega adaptor base with shorting clip
HFI-DDBS-01    Vega deep adaptor base with shorting clip
HFI-DMBS-05    Low profile adaptor base
WAB 100         Wireless Adaptor Base

 


 

To read the Red Book section introduction click here.

 

< back to results page