Kelvinstraat 7
NL-6003DH
Weert
The Netherlands
Tel: + 31 495 58 30 00
•
Fax: + 31 495 55 00 42
Email: David.Perez@fs.utc.com
•
Web: www.utcfireandsecurity.com
Certificate No 1199a-(cl-1) to EN 54-2:1997 + A1:2006 , EN 54-4:1997+ A1:2002 +A2:2006 and EN 54-21:2006
Certificate No 1199b-(cl-1) to EN 54-2:1997+A1:2006, EN 54-4:1997+A1:2006 + A2:2006
Control and indicating equipment
Product | Description | LPCB Ref. No. |
---|---|---|
2X-F1-SC, 2X-F1-SC-S | Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop small cabinet (Scandinavia)
Incorporating the following units:
2010-2F1-MB Main control board 2X-UI-SC User interface control board 2010-2-PS-40 4A Power Supply And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/06 |
2X-F1-FB2-S, 2X-F1-FB2 | Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop small cabinet
Incorporating the following units:
2010-2F1-MB Main control board 2X-UI-FB2 User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB Peripheral Interface Board (Germany) (Large cabinet variant only) 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) ADP-N3E-U IFAM interface card (master) (Large cabinet variant only) ADP-N3S interface card (slave) (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2X-D-FB2-TP Translucent door option for large cabinet* 2X-D-FB2-TP-S Translucent door option for small cabinet* 2010-FS-EOL Fault Supervision End of Line unit |
1199a/07 |
2X-E1, 2X-E1-S | Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 1 loop Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 1 loop small Cabinet
Incorporating the following units:
2010-2F1-MB Main control board 2X-UI-E User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2X-D-E-TP Translucent door option for large cabinet* 2X-D-E-TP-S Translucent door option for small cabinet* 2010-FS-EOL Fault Supervision End of Line unit
|
1199a/08 |
2X-F1-SCFB-S, 2X-F1-SCFB | Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 1 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 1 loop small cabinet (Scandinavia)
Incorporating the following units:
2010-2F1-MB Main control board 2X-UI-SCFB User interface control board 2010-2-PS-40 4A Power Supply And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit
The above fire panels are certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment (not available on 2X-
F1 and 2X-F1-S)
7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10 Output to fire protection equipment - Type A,B and C (notavailable on 2X-F1 and 2X-F1-S) 7.11 Delays to outputs 7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Available with the following language kit options: -01 Dutch (NL) The Netherlands, -02 French (FR), -03 English (UK) United Kingdom and Ireland, -04 German (DE) -05 Norwegian, -06 Swedish, -07 Danish (DK), -08 English (AU) Australia, -09 Spanish, -10 Italian, -11 Dutch (BE) Belgium, -12 Irish, -13 German (AU) (Austria), -14 Greek, -15 Arabic, -17 English (US) United States of America, -18 Polish, -19 Turkish, -20 Czech Republic, -21 Portuguese, -22 Hungarian, -23 Danish (IC) Iceland, -24 Slovakian, -25 Russian, -27 Lithuanian, -28 Finnish, -29 German (SW) Switzerland, -30 Estonian,-31 Latvian, - 32 French (BE) Belgium, -33 French (SW) Switzerland, -34 Italian (SW) Switzerland, -36 French (Int) International, -40 Bulgarian, -41 Belarusian, -43 Ukrainian, -44 Serbian, -45 Romanian (RO), -46 German (Int) International, -48 Croatian, -49 Macedonian, -50 Slovenian, -51 Hebrew, -71 Catalan, -80 Chinese, -99 English (Int) International English 2. Scope of the approval does not indicate the operation of the network functionality *The translucent door does not meet EN54-2 access level 1 requirements. To meet EN54-2 requirements with the door fitted the following is also required: 3. A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2 part 7.3) 4. A MCP (without program delay) fitted beside the panel to allow overriding of delays (to meet requirements of EN54-2 part 7.11) |
1199a/09 |
2X-FR, 2X-FR-S | Intelligent Analogue Addressable Fire Panel Repeater Intelligent Analogue Addressable Fire Panel Repeater small cabinet
Incorporating the following units:
2010-2FR-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2X-D-TP Translucent door option for large cabinet* 2X-D-TP-S Translucent door option for small cabinet* 2010-FS-EOL Fault Supervision End of Line unit |
1199a/R01 |
2X-FR-SC | Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls (Scandinavia) Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small cabinet (Scandinavia)
Incorporating the following units:
2010-2FR-MB Main control board 2X-UI-SC User interface control board 2010-2-PS-40 4A Power Supply And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB Peripheral Interface Board (Germany) 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/R03 |
2X-FR-FB2, 2X-FR-FB2-S | Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small cabinet
Incorporating the following units:
2010-2FR-MB Main control board 2X-UI-FB2 User interface control board 2010-2-PS-40 4A Power Supply And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB Peripheral Interface Board (Germany) (Large cabinet variant only) 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) ADP-N3E-U IFAM interface card (master) (Large cabinet variant only) ADP-N3S interface card (slave) (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2X-D-FB2-TP Translucent door option for large cabinet* 2X-D-FB2-TP-S Translucent door option for small cabinet* 2010-FS-EOL Fault Supervision End of Line unit |
1199a/R02 |
2X-FR-SCFB, 2X-FR-SCFB-S | Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls (Scandinavia) Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls small cabinet (Scandinavia)
Incorporating the following units:
2010-2FR-MB Main control board 2X-UI-SCFB User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/R05 |
2X-ER, 2X-ER-S | Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade controls Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade controls small cabinet
Incorporating the following units:
2010-2FR-MB Main control board 2X-UI-E User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2X-D-E-TP Translucent door option for large cabinet* 2X-D-E-TP-S Translucent door option for small cabinet* 2010-FS-EOL Fault Supervision End of Line unit
The above ancillary repeater units are certified with the following options with requirements from EN 54-2:
7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points (available on 2X-ER and 2X-ER-S variants only) 10 Test condition (available on 2X-ER and 2X-ER-S variants only)
*Important: the translucent door does not meet EN54-2 access level 1 requirements. To meet EN54-2 requirements with the door fitted the following is also required:
1) A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2 part 7.3)
2) An MCP fitted beside the panel to allow overriding of delays (to meet requirements of EN54-2 part 7.11) |
1199a/R04 |
KFP-AF1, KFP-AF1-S | Intelligent Analogue Addressable Fire Panel with user interface - 1 loop Intelligent Analogue Addressable Fire Panel with user interface - 1 loop small cabinet
Incorporating the following units:
2010-2F1-MB Main control board KFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/05 |
KFP-AF1-SC, KFP-AF1-SC-S | Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop small cabinet (Scandinavia)
Incorporating the following units:
2010-2F1-MB Main control board KFP-A-UI-SC User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only)
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/06 |
KFP-AF1-SCFB, KFP-AF1-SCFB-S | Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 1 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop with printer
Incorporating the following units:
2010-2F1-MB Main control board KFP-A-UI-SCFB User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/09 |
KFP-AE1, KFP-AE1-S | Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 1 loop Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 1 loop small cabinet
Incorporating the following units:
2010-2F1-MB Main control board KFP-A-UI-E User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit
The above fire panels are certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment (not available on
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10 Output to fire protection equipment - Type A,B and C (not 7.11 Delays to outputs
7.12 Dependencies on more than one alarm signal (Type A, B and 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 1. Available with the following language kit options: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland-13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia- 27 Lithuanian Lithuania-28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English 2. Scope of the approval does not indicate the operation of the networkfunctionality |
1199a/08 |
KFP-A-FR, KFP-A-FR-S | Intelligent Analogue Addressable Fire Panel Repeater Intelligent Analogue Addressable Fire Panel Repeater small cabinet
Incorporating the following units:
2010-2FR-MB Main control board KFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/R01 |
KFP-A-FR-SC, KFP-A-FR-SC-S | Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls (Scandinavia) Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small cabinet (Scandinavia)
Incorporating the following units:
2010-2FR-MB Main control board KFP-A-UI-SC User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/R03 |
KFP-A-FR-FB2-S, KFP-A-FR-FB2 | Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small cabinet
Incorporating the following units:
2010-2FR-MB Main control board KFP-A-UI-FB2 User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB Peripheral Interface Board (Germany) (Large cabinet variant
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large ADP-N3E-U IFAM interface card (master) (Large cabinet variant only) ADP-N3S interface card (slave) (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/R02 |
KFP-A-FR-SCFB, KFP-A-FR-SCFB-S | Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls (Scandinavia) Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls small cabinet (Scandinavia)
Incorporating the following units:
2010-2FR-MB Main control board KFP-A-UI-SCFB User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/R05 |
KFP-A-ER KFP-A-ER-S | Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade controls Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade controls small cabinet
Incorporating the following units:
2010-2FR-MB Main control board KFP-A-UI-E User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit
Above ancillary repeater units are certified with the following options with requirements from EN 54-2:
7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment
9.5 Disablement of addressable points (available on 2X-ER and 10 Test condition (available on 2X-ER and 2X-ER-S variants only |
1199a/R04 |
2X-F2, 2X-F2-PRT, 2X-F2-S | Intelligent Analogue Addressable Fire Panel with user interface - 2 loop Intelligent Analogue Addressable Fire Panel with user interface - 2 loop with printer Intelligent Analogue Addressable Fire Panel with user interface - 2 loop small cabinet
Incorporating the following units:
2010-2F2-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PRT Door mounted printer module (2X-F2-PRT variant only)
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module)
2X-D-TP Translucent door option for large cabinet* (2X-F2 variant
2X-D-TP-S Translucent door option for small cabinet* (2X-F2-S variant 2010-FS-EOL Fault Supervision End of Line unit |
1199a/10 |
2X-F2-SC, 2X-F2-SC-S | Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop small cabinet (Scandinavia)
Incorporating the following units:
2010-2F2-MB Main control board 2X-UI-SC User interface control board 2010-2-PS-40 4A Power Supply And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/11 |
2X-F2-FB2-PRT, 2X-F2-FB2, 2X-F2-FB2-S | Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop with printer Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop small cabinet
Incorporating the following units:
2010-2F2-MB Main control board 2X-UI-FB2 User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PRT Door mounted printer module (2X-F2-FB2-PRT variant only)
2010-2-PIB Peripheral Interface Board (Germany) (Large cabinet variant
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large ADP-N3E-U (Large cabinet variant only) ADP-N3S (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2X-D-FB2-TP Translucent door option for large cabinet* (2X-F2-FB2 variant only)
2X-D-FB2-TP-S Translucent door option for large cabinet* (2X-F2-FB2-S 2010-FS-EOL Fault Supervision End of Line unit |
1199a/12 |
2X-F2-SCFB, 2X-F2-SCFB-S | Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 2 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 2 loop small cabinet (Scandinavia)
Incorporating the following units:
2010-2F2-MB Main control board 2X-UI-SCFB User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/13 |
2X-E2, 2X-E2-S | Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 2 loop Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 2 loop small cabinet
Incorporating the following units:
2010-2F2-MB Main control board 2X-UI-E User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2X-D-E-TP Translucent door option for large cabinet* 2X-D-E-TP-S Translucent door option for large cabinet* 2010-FS-EOL Fault Supervision End of Line unit
The above fire panels are certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment (not available on 2X-
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10 Output to fire protection equipment - Type A,B and C (not 7.11 Delays to outputs
7.12 Dependencies on more than one alarm signal (Type A, B and 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13 . 1.Available with the following language kit options: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 1. Available with the following language kits:-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland-13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary-23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania-28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English2.Scope of the approval does not indicate the operation of the network functionality
*The translucent door does not meet EN54-2 access level 1 requirements. To meet EN54-2 requirements with the door fitted the following is also required: 3. A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2 part 7.3) 4. A MCP (without program delay) fitted beside the panel to allow overriding of delays (to meet requirements of EN54-2 part 7.11) |
1199a/14 |
KFP-AF2,KFP-AF2-PRT, KFP-AF2-S | Intelligent Analogue Addressable Fire Panel with user interface - 2 loop Intelligent Analogue Addressable Fire Panel with user interface - 2 loop with printer Intelligent Analogue Addressable Fire Panel with user interface - 2 loop small cabinet
Incorporating the following units:
2010-2F2-MB Main control board KFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PRT Door mounted printer module (KFP-A-F2-PRT variant only)
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/10 |
KFP-AF2-SC, KFP-AF2-SC-S | Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop small cabinet (Scandinavia)
Incorporating the following units:
2010-2F2-MB Main control board KFP-A-UI-SC User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/11 |
KFP-A-F2FB2-PRT KFP-AF2-FB2-S KFP-AF2-FB2 | Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop with printer Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop small cabinet
Incorporating the following units:
2010-2F2-MB Main control board KFP-A-UI-FB2 User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PRT Door mounted printer module (KFP-A-F2-FB2-PRT variant
2010-2-PIB Peripheral Interface Board (Germany) (Large cabinet variant
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large ADP-N3E-U (Large cabinet variant only) ADP-N3S (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/12 |
KFP-AF2-SCFB-S, KFP-AF2-SCFB | Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 2 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 2 loop small cabinet (Scandinavia)
Incorporating the following units:
2010-2F2-MB Main control board KFP-A-UI-SCFB User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PRT Door mounted printer module (KFP-A-F2-SCFB-PRT variant
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/13 |
KFP-AE2, KFP-AE2-S | Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 2 loop Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 2 loop small cabinet
Incorporating the following units:
2010-2F2-MB Main control board KFP-A-UI-E User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit
The above fire panels are certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment (not available on KFP-
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10 Output to fire protection equipment - Type A,B and C (not 7.11 Delays to outputs
7.12 Dependencies on more than one alarm signal (Type A, B and 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 1. Available with the following language kit options: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland-13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania-28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33 French (SW) Switzerland- 34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English 2. Scope of the approval does not indicate the operation of the network functionality |
1199a/14 |
ZP2-F1-S, ZP2-F1 | Intelligent Analogue Addressable Fire Panel with user interface - 1 loop Intelligent Analogue Addressable Fire Panel with user interface - 1 loop small cabinet
Incorporating the following units:
2010-2F1-MB Main control board ZP2-UI User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-TP Translucent door option for large cabinet* ZP2-D-TP-S Translucent door option for small cabinet* |
1199a/05 |
ZP2-F1-SC, ZP2-F1-SC-S | Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop small cabinet (Scandinavia)
Incorporating the following units:
2010-2F1-MB Main control board ZP2-UI-SC User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/06 |
ZP2-F1-FB2, ZP2-F1-FB2-S | Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop small cabinet
Incorporating the following units:
2010-2F1-MB Main control board ZP2-UI-FB2 User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB Peripheral Interface Board (Germany) (Large cabinet variant
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large ADP-N3E-U IFAM interface card (master) (Large cabinet variant only) ADP-N3S interface card (slave) (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-FB2-TP Translucent door option for large cabinet* ZP2-D-FB2-TP-S Translucent door option for small cabinet* |
1199a/07 |
ZP2-F1-SCFB, ZP2-F1-SCFB-S | Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 1 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 1 loop small cabinet (Scandinavia)
Incorporating the following units:
2010-2F1-MB Main control board ZP2-UI-SCFB User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/09 |
ZP2-E1, ZP2-E1-S | Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 1 loop Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 1 loop small cabinet
Incorporating the following units:
2010-2F1-MB Main control board ZP2-UI-E User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-E-TP Translucent door option for large cabinet* ZP2-D-E-TP-S Translucent door option for small cabinet*
The above fire panels are certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment (not available on ZP2-
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10 Output to fire protection equipment - Type A,B and C (not 7.11 Delays to outputs
7.12 Dependencies on more than one alarm signal (Type A, B and 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 1. Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland-13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania-28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English 2. Scope of the approval does not indicate the operation of the network functionality *The translucent door does not meet EN54-2 access level 1 requirements. To meet EN54-2 requirements with the door fitted the following is also required: 3. A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2 part 7.3) 4. A MCP (without program delay) fitted beside the panel to allow overriding of delays (to meet requirements of EN54-2 part 7.11) |
1199a/08 |
ZP2-FR, ZP2-FR-S | Intelligent Analogue Addressable Fire Panel Repeater Intelligent Analogue Addressable Fire Panel Repeater small cabinet
Incorporating the following units:
2010-2FR-MB Main control board ZP2-UI User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-TP Translucent door option for large cabinet* ZP2-D-TP-S Translucent door option for small cabinet* |
1199a/R01 |
ZP2-FR-SC, ZP2-FR-SC-S | Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls (Scandinavia) Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small cabinet (Scandinavia)
Incorporating the following units:
2010-2FR-MB Main control board ZP2-UI-SC User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Inte rface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/R03 |
ZP2-FR-FB2 ZP2-FR-FB2-S | Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small cabinet
Incorporating the following units:
2010-2FR-MB Main control board ZP2-UI-FB2 User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB Peripheral Interface Board (Germany) (Large cabinet variant
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large ADP-N3E-U IFAM interface card (master) (Large cabinet variant only) ADP-N3S interface card (slave) (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-FB2-TP Translucent door option for large cabinet* ZP2-D-FB2-TP-S Translucent door option for small cabinet* |
1199a/R02 |
ZP2-FR-SCFB, ZP2-FR-SCFB-S | Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls (Scandinavia) Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls small cabinet (Scandinavia)
Incorporating the following units:
2010-2FR-MB Main control board ZP2-UI-SCFB User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/R05 |
ZP2-ER, ZP2-ER-S | Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade controls Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade controls small cabinet
Incorporating the following units:
2010-2FR-MB Main control board ZP2-UI-E User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-E-TP Translucent door option for large cabinet* ZP2-D-E-TP-S Translucent door option for small cabinet
Certified with the following options with requirements from EN 54-2:
7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment
9.5 Disablement of addressable points (available on 2X-ER and 2X- 10 Test condition (available on 2X-ER and 2X-ER-S variants only) |
1199a/R04 |
ZP2-F2, ZP2-F2-PRT, ZP2-F2-S | Intelligent Analogue Addressable Fire Panel with user interface - 2 loop Intelligent Analogue Addressable Fire Panel with user interface - 2 loop with printer Intelligent Analogue Addressable Fire Panel with user interface - 2 loop small cabinet
Incorporating the following units:
2010-2F2-MB Main control board ZP2-UI User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PRT Door mounted printer module (ZP2-F2-PRT variant only)
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-TP Translucent door option for large cabinet* (ZP2-F2 variant only)
ZP2-D-TP-S Translucent door option for small cabinet* (ZP2-F2-S variant |
1199a/10 |
ZP2-F2-SC, ZP2-F2-SC-S | Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop small cabinet (Scandinavia)
Incorporating the following units:
2010-2F2-MB Main control board ZP2-UI-SC User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/11 |
ZP2-F2-FB2, ZP2-F2-FB2 PRT, ZP2F2-FB2-S | Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop with printer Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop small cabinet
Incorporating the following units:
2010-2F2-MB Main control board ZP2-UI-FB2 User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PRT Door mounted printer module (ZP2-F2-FB2-PRT variant only)
2010-2-PIB Peripheral Interface Board (Germany) (Large cabinet variant
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large ADP-N3E-U (Large cabinet variant only) ADP-N3S (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit
ZP2-D-FB2-TP Translucent door option for large cabinet* (ZP2-F2-FB2 variant
ZP2-D-FB2-TP-S Translucent door option for large cabinet* (ZP2-F2-FB2-S variant |
1199a/12 |
ZP2-F2-SCFB-S,ZP2-F2-SCFB-PRT,ZP2-F2-SCFB | Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 2 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 2 loop with printer (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 2 loop small cabinet (Scandinavia)
Incorporating the following units:
2010-2F2-MB Main control board ZP2-UI-SCFB User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PRT Door mounted printer module (ZP2-F2-SCFB-PRT variant
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/13 |
ZP2-E2, ZP2-E2-S | Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 2 loop Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 2 loop small cabinet
Incorporating the following units:
2010-2F2-MB Main control board ZP2-UI-E User interface control board 2010-2-PS-40 4A Power Supply And as optional modules: ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-E-TP Translucent door option for large cabinet* ZP2-D-E-TP-S Translucent door option for large cabinet*
The above fire panels are certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment (not available on ZP2-
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10 Output to fire protection equipment - Type A,B and C (not 7.11 Delays to outputs
7.12 Dependencies on more than one alarm signal (Type A, B and 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 1. Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland-13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania-28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33 French (SW) Switzerland- 34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English 2. Scope of the approval does not indicate the operation of the network functionality *The translucent door does not meet EN54-2 access level 1 requirements. To meet EN54-2 requirements with the door fitted the following is also required: 3. A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2 part 7.3) 4. A MCP (without program delay) fitted beside the panel to allow overriding of delays (to meet requirements of EN54-2 part 7.11) |
1199a/14 |
1X-F2 1X-F2-SC | 1X-F2 Conventional Two Zone Control and Indicating Equipment 1X-F2-SC Conventional Two Zone Control and Indicating Equipment with Scandinavian Key Switch
Incorporating the following units: 1X-F2-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-20 using LRS-75-24 2A Power Supply 2010-SK Scandinavian Key Lock and Key (Applicable to 'SC' variant)
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.11 Delays to outputs 8.4 Total loss of the power supply 10 Test condition Notes: 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. International English 3) Available with the following language kits: 01 Dutch (NL) The Netherlands, 02 French (FR) France , 03 English (UK) United Kingdom and Ireland, 04 German (DE) Germany, 05 Norwegian Norway, 06 Swedish Sweden, 07 Danish (DK) Denmark, 08 English (AU) Australia, 09 Spanish Spain, 10 Italian Italy, 11 Dutch (BE) Belgium, 12 Irish Ireland, 13 German (AU) German (Austria), 14 Greek Greece, 15 Arabic Middle East, 17 English (US) United States of America, 18 Polish Poland, 19 Turkish Turkey, 20 Czech Czech Republic, 21 Portuguese Portugal, 22 Hungarian Hungary, 23 Danish (IC) Iceland, 24 Slovakian Slovak Republic, 25 Russian Russia, 27 Lithuanian Lithuania, 28 Finnish Finland, 29 German (SW) Switzerland, 30 Estonian Estonia, 31 Latvian Latvia, 32 French (BE) Belgium, 33 French (SW) Switzerland, 34 Italian (SW) Switzerland, 36 French (Int) International French, 40 Bulgarian Bulgaria, 41 Belarusian Belarus, 43 Ukrainian Ukraine, 44 Serbian Serbia, 45 Romanian (RO) Romania, 46 German (Int) International German, 48 Croatian Croatia, 49 Macedonian Macedonia, 50 Slovenian Slovenia, 51 Hebrew Israel, 71 Catalan Catalonia (Spain), 80 Chinese China, 99 English (Int) International English |
1199b/01 |
KFP-CF2 KFP-CF2-SC | KFP-CF2 Conventional Two Zone Control and Indicating Equipment KFP-CF2-SC Conventional Two Zone Control and Indicating Equipment with Scandinavian Key Switch
Incorporating the following units: KFP-CF2-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-20 using LRS-75-24 2A Power Supply 2010-SK Scandinavian Key Lock and Key (Applicable to 'SC' variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.11 Delays to outputs 8.4 Total loss of the power supply 10 Test condition Notes: 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch (NL) The Netherlands, 02 French (FR) France , 03 English (UK) United Kingdom and Ireland, 04 German (DE) Germany, 05 Norwegian Norway, 06 Swedish Sweden, 07 Danish (DK) Denmark, 08 English (AU) Australia, 09 Spanish Spain, 10 Italian Italy, 11 Dutch (BE) Belgium, 12 Irish Ireland, 13 German (AU) German (Austria), 14 Greek Greece, 15 Arabic Middle East, 17 English (US) United States of America, 18 Polish Poland, 19 Turkish Turkey, 20 Czech Czech Republic, 21 Portuguese Portugal, 22 Hungarian Hungary, 23 Danish (IC) Iceland, 24 Slovakian Slovak Republic, 25 Russian Russia, 27 Lithuanian Lithuania, 28 Finnish Finland, 29 German (SW) Switzerland, 30 Estonian Estonia, 31 Latvian Latvia, 32 French (BE) Belgium, 33 French (SW) Switzerland, 34 Italian (SW) Switzerland, 36 French (Int) International French, 40 Bulgarian Bulgaria, 41 Belarusian Belarus, 43 Ukrainian Ukraine, 44 Serbian Serbia, 45 Romanian (RO) Romania, 46 German (Int) International German, 48 Croatian Croatia, 49 Macedonian Macedonia, 50 Slovenian Slovenia, 51 Hebrew Israel, 71 Catalan Catalonia (Spain), 80 Chinese China, 99 English (Int) International English |
1199b/01 |
1X-F4 1X-F4-NL 1X-F4-SC | 1X-F4 Conventional Four Zone Control and Indicating Equipment 1X-F4-NL Conventional Four Zone Control and Indicating Equipment 1X-F4-SC Conventional Four Zone Control and Indicating Equipment with Scandinavian Key Switch
Incorporating the following units: 1X-F4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Expander I/O board 2010-1-NB Optional Network board 2010-PS-20 using LRS-75-24 2A Power Supply 2010-1-AC Alarm Counter (Applicable to 'NL' variant) 2010-SK Scandinavian Key Lock and Key (Applicable to 'SC' variant)
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 10 Test condition
Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition Notes: 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch (NL) The Netherlands, 02 French (FR) France , 03 English (UK) United Kingdom and Ireland, 04 German (DE) Germany, 05 Norwegian Norway, 06 Swedish Sweden, 07 Danish (DK) Denmark, 08 English (AU) Australia, 09 Spanish Spain, 10 Italian Italy, 11 Dutch (BE) Belgium, 12 Irish Ireland, 13 German (AU) German (Austria), 14 Greek Greece, 15 Arabic Middle East, 17 English (US) United States of America, 18 Polish Poland, 19 Turkish Turkey, 20 Czech Czech Republic, 21 Portuguese Portugal, 22 Hungarian Hungary, 23 Danish (IC) Iceland, 24 Slovakian Slovak Republic, 25 Russian Russia, 27 Lithuanian Lithuania, 28 Finnish Finland, 29 German (SW) Switzerland, 30 Estonian Estonia, 31 Latvian Latvia, 32 French (BE) Belgium, 33 French (SW) Switzerland, 34 Italian (SW) Switzerland, 36 French (Int) International French, 40 Bulgarian Bulgaria, 41 Belarusian Belarus, 43 Ukrainian Ukraine, 44 Serbian Serbia, 45 Romanian (RO) Romania, 46 German (Int) International German, 48 Croatian Croatia, 49 Macedonian Macedonia, 50 Slovenian Slovenia, 51 Hebrew Israel, 71 Catalan Catalonia (Spain), 80 Chinese China, 99 English (Int) International English |
1199b/02 |
KFP-CF4 KFP-CF4-NL KFP-CF4-SC | KFP-CF4 Conventional Four Zone Control and Indicating Equipment KFP-CF4-NL Conventional Four Zone Control and Indicating Equipment KFP-CF4-SC Conventional Four Zone Control and Indicating Equipment with Scandinavian Key Switch
Incorporating the following units: KFP-CF4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Expander I/O board 2010-1-NB Optional Network board 2010-PS-20 using LRS-75-24 2A Power Supply 2010-1-AC Alarm Counter (Applicable to 'NL' variant) 2010-SK Scandinavian Key Lock and Key (Applicable to 'SC' variant)
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 10 Test condition
Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition Notes: 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch (NL) The Netherlands, 02 French (FR) France , 03 English (UK) United Kingdom and Ireland, 04 German (DE) Germany, 05 Norwegian Norway, 06 Swedish Sweden, 07 Danish (DK) Denmark, 08 English (AU) Australia, 09 Spanish Spain, 10 Italian Italy, 11 Dutch (BE) Belgium, 12 Irish Ireland, 13 German (AU) German (Austria), 14 Greek Greece, 15 Arabic Middle East, 17 English (US) United States of America, 18 Polish Poland, 19 Turkish Turkey, 20 Czech Czech Republic, 21 Portuguese Portugal, 22 Hungarian Hungary, 23 Danish (IC) Iceland, 24 Slovakian Slovak Republic, 25 Russian Russia, 27 Lithuanian Lithuania, 28 Finnish Finland, 29 German (SW) Switzerland, 30 Estonian Estonia, 31 Latvian Latvia, 32 French (BE) Belgium, 33 French (SW) Switzerland, 34 Italian (SW) Switzerland, 36 French (Int) International French, 40 Bulgarian Bulgaria, 41 Belarusian Belarus, 43 Ukrainian Ukraine, 44 Serbian Serbia, 45 Romanian (RO) Romania, 46 German (Int) International German, 48 Croatian Croatia, 49 Macedonian Macedonia, 50 Slovenian Slovenia, 51 Hebrew Israel, 71 Catalan Catalonia (Spain), 80 Chinese China, 99 English (Int) International English |
1199b/02 |
ZP1-F4 ZP1-F4-NL ZP1-F4-SC | ZP1-F4 Conventional Four Zone Control and Indicating Equipment ZP1-F4-NL Conventional Four Zone Control and Indicating Equipment ZP1-F4-SC Conventional Four Zone Control and Indicating Equipment with Scandinavian Key Switch
Incorporating the following units: 1X-F4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Expander I/O board 2010-1-NB Optional Network board 2010-PS-20 using LRS-75-24 2A Power Supply 2010-1-AC Alarm Counter (Applicable to 'NL' variant) 2010-SK Scandinavian Key Lock and Key (Applicable to 'SC' variant)
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 10 Test condition
Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition Notes: 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch (NL) The Netherlands, 02 French (FR) France , 03 English (UK) United Kingdom and Ireland, 04 German (DE) Germany, 05 Norwegian Norway, 06 Swedish Sweden, 07 Danish (DK) Denmark, 08 English (AU) Australia, 09 Spanish Spain, 10 Italian Italy, 11 Dutch (BE) Belgium, 12 Irish Ireland, 13 German (AU) German (Austria), 14 Greek Greece, 15 Arabic Middle East, 17 English (US) United States of America, 18 Polish Poland, 19 Turkish Turkey, 20 Czech Czech Republic, 21 Portuguese Portugal, 22 Hungarian Hungary, 23 Danish (IC) Iceland, 24 Slovakian Slovak Republic, 25 Russian Russia, 27 Lithuanian Lithuania, 28 Finnish Finland, 29 German (SW) Switzerland, 30 Estonian Estonia, 31 Latvian Latvia, 32 French (BE) Belgium, 33 French (SW) Switzerland, 34 Italian (SW) Switzerland, 36 French (Int) International French, 40 Bulgarian Bulgaria, 41 Belarusian Belarus, 43 Ukrainian Ukraine, 44 Serbian Serbia, 45 Romanian (RO) Romania, 46 German (Int) International German, 48 Croatian Croatia, 49 Macedonian Macedonia, 50 Slovenian Slovenia, 51 Hebrew Israel, 71 Catalan Catalonia (Spain), 80 Chinese China, 99 English (Int) International English |
1199b/02 |
1X-F8 1X-F8-NL 1X-F8-SC | 1X-F8 Conventional Eight Zone Control and Indicating Equipment 1X-F8-NL Conventional Eight Zone Control and Indicating Equipment 1x-F8-SC Conventional Eight Zone Control and Indicating Equipment with Scandinavian Key Switch
Incorporating the following units: 1X-F8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Expander I/O board 2010-1-NB Optional Network board 2010-PS-40 using LRS-100-24 4A Power Supply 2010-1-AC Alarm Counter (Applicable to 'NL' variant) 2010-SK Scandinavian Key Lock and Key (Applicable to 'SC' variant)
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 10 Test condition Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition Notes: 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch (NL) The Netherlands, 02 French (FR) France , 03 English (UK) United Kingdom and Ireland, 04 German (DE) Germany, 05 Norwegian Norway, 06 Swedish Sweden, 07 Danish (DK) Denmark, 08 English (AU) Australia, 09 Spanish Spain, 10 Italian Italy, 11 Dutch (BE) Belgium, 12 Irish Ireland, 13 German (AU) German (Austria), 14 Greek Greece, 15 Arabic Middle East, 17 English (US) United States of America, 18 Polish Poland, 19 Turkish Turkey, 20 Czech Czech Republic, 21 Portuguese Portugal, 22 Hungarian Hungary, 23 Danish (IC) Iceland, 24 Slovakian Slovak Republic, 25 Russian Russia, 27 Lithuanian Lithuania, 28 Finnish Finland, 29 German (SW) Switzerland, 30 Estonian Estonia, 31 Latvian Latvia, 32 French (BE) Belgium, 33 French (SW) Switzerland, 34 Italian (SW) Switzerland, 36 French (Int) International French, 40 Bulgarian Bulgaria, 41 Belarusian Belarus, 43 Ukrainian Ukraine, 44 Serbian Serbia, 45 Romanian (RO) Romania, 46 German (Int) International German, 48 Croatian Croatia, 49 Macedonian Macedonia, 50 Slovenian Slovenia, 51 Hebrew Israel, 71 Catalan Catalonia (Spain), 80 Chinese China, 99 English (Int) International English |
1199b/03 |
KFP-CF8 KFP-CF8-NL KFP-CF8-SC | KFP-CF8Conventional Eight Zone Control and Indicating Equipment KFP-CF8-NLConventional Eight Zone Control and Indicating Equipment KFP-CF8-SCConventional Eight Zone Control and Indicating Equipment with Scandinavian Key Switch
Incorporating the following units: KFP-CF8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Expander I/O board 2010-1-NB Optional Network board 2010-PS-40 using LRS-100-24 4A Power Supply 2010-1-AC Alarm Counter (Applicable to 'NL' variant) 2010-SK Scandinavian Key Lock and Key (Applicable to 'SC' variant)
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 10 Test condition
Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition Notes: 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch (NL) The Netherlands, 02 French (FR) France , 03 English (UK) United Kingdom and Ireland, 04 German (DE) Germany, 05 Norwegian Norway, 06 Swedish Sweden, 07 Danish (DK) Denmark, 08 English (AU) Australia, 09 Spanish Spain, 10 Italian Italy, 11 Dutch (BE) Belgium, 12 Irish Ireland, 13 German (AU) German (Austria), 14 Greek Greece, 15 Arabic Middle East, 17 English (US) United States of America, 18 Polish Poland, 19 Turkish Turkey, 20 Czech Czech Republic, 21 Portuguese Portugal, 22 Hungarian Hungary, 23 Danish (IC) Iceland, 24 Slovakian Slovak Republic, 25 Russian Russia, 27 Lithuanian Lithuania, 28 Finnish Finland, 29 German (SW) Switzerland, 30 Estonian Estonia, 31 Latvian Latvia, 32 French (BE) Belgium, 33 French (SW) Switzerland, 34 Italian (SW) Switzerland, 36 French (Int) International French, 40 Bulgarian Bulgaria, 41 Belarusian Belarus, 43 Ukrainian Ukraine, 44 Serbian Serbia, 45 Romanian (RO) Romania, 46 German (Int) International German, 48 Croatian Croatia, 49 Macedonian Macedonia, 50 Slovenian Slovenia, 51 Hebrew Israel, 71 Catalan Catalonia (Spain), 80 Chinese China, 99 English (Int) International English |
1199b/03 |
ZP1-F8 ZP1-F8-NL ZP1-F8-SC | ZP1-F8 Conventional Four Zone Control and Indicating Equipment ZP1-F8-NL Conventional Four Zone Control and Indicating Equipment ZP1-F8-SC Conventional Four Zone Control and Indicating Equipment with Scandinavian Key Switch
Incorporating the following units: 1X-F8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Expander I/O board 2010-1-NB Optional Network board 2010-PS-40 using LRS-100-24 4A Power Supply 2010-1-AC Alarm Counter (Applicable to 'NL' variant) 2010-SK Scandinavian Key Lock and Key (Applicable to 'SC' variant)
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition
Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition Notes: 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch (NL) The Netherlands, 02 French (FR) France , 03 English (UK) United Kingdom and Ireland, 04 German (DE) Germany, 05 Norwegian Norway, 06 Swedish Sweden, 07 Danish (DK) Denmark, 08 English (AU) Australia, 09 Spanish Spain, 10 Italian Italy, 11 Dutch (BE) Belgium, 12 Irish Ireland, 13 German (AU) German (Austria), 14 Greek Greece, 15 Arabic Middle East, 17 English (US) United States of America, 18 Polish Poland, 19 Turkish Turkey, 20 Czech Czech Republic, 21 Portuguese Portugal, 22 Hungarian Hungary, 23 Danish (IC) Iceland, 24 Slovakian Slovak Republic, 25 Russian Russia, 27 Lithuanian Lithuania, 28 Finnish Finland, 29 German (SW) Switzerland, 30 Estonian Estonia, 31 Latvian Latvia, 32 French (BE) Belgium, 33 French (SW) Switzerland, 34 Italian (SW) Switzerland, 36 French (Int) International French, 40 Bulgarian Bulgaria, 41 Belarusian Belarus, 43 Ukrainian Ukraine, 44 Serbian Serbia, 45 Romanian (RO) Romania, 46 German (Int) International German, 48 Croatian Croatia, 49 Macedonian Macedonia, 50 Slovenian Slovenia, 51 Hebrew Israel, 71 Catalan Catalonia (Spain), 80 Chinese China, 99 English (Int) International English |
1199b/03 |
1X-E4 1X-E4-NL | 1X-E4 Conventional Four Zone Control and Indicating Equipment 1X-E4-NL Conventional Four Zone Control and Indicating Equipment
Incorporating the following units: 1X-E4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Expander I/O board 2010-1-NB Optional Network board 2010-PS-40 using LRS-100-24 4A Power Supply 2010-1-AC Alarm Counter (Applicable to 'NL' variant)
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 10 Test condition
Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to 'NL' variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition Notes: 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch (NL) The Netherlands, 02 French (FR) France , 03 English (UK) United Kingdom and Ireland, 04 German (DE) Germany, 05 Norwegian Norway, 06 Swedish Sweden, 07 Danish (DK) Denmark, 08 English (AU) Australia, 09 Spanish Spain, 10 Italian Italy, 11 Dutch (BE) Belgium, 12 Irish Ireland, 13 German (AU) German (Austria), 14 Greek Greece, 15 Arabic Middle East, 17 English (US) United States of America, 18 Polish Poland, 19 Turkish Turkey, 20 Czech Czech Republic, 21 Portuguese Portugal, 22 Hungarian Hungary, 23 Danish (IC) Iceland, 24 Slovakian Slovak Republic, 25 Russian Russia, 27 Lithuanian Lithuania, 28 Finnish Finland, 29 German (SW) Switzerland, 30 Estonian Estonia, 31 Latvian Latvia, 32 French (BE) Belgium, 33 French (SW) Switzerland, 34 Italian (SW) Switzerland, 36 French (Int) International French, 40 Bulgarian Bulgaria, 41 Belarusian Belarus, 43 Ukrainian Ukraine, 44 Serbian Serbia, 45 Romanian (RO) Romania, 46 German (Int) International German, 48 Croatian Croatia, 49 Macedonian Macedonia, 50 Slovenian Slovenia, 51 Hebrew Israel, 71 Catalan Catalonia (Spain), 80 Chinese China, 99 English (Int) International English |
1199b/04 |
KFP-AF1-FB2, KFP-AF1-FB2-S | Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop small cabinet
Incorporating the following units:
2010-2F1-MB Main control board KFP-A-UI-FB2 User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB Peripheral Interface Board (Germany) (Large cabinet variant
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large ADP-N3E-U IFAM interface card (master) (Large cabinet variant only) ADP-N3S interface card (slave) (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit |
1199a/07 |
ZP1-F2 ZP1-F2-SC | ZP1-F2 Conventional Two Zone Control and Indicating Equipment ZP1-F2-SC Conventional Two Zone Control and Indicating Equipment with Scandinavian Key Switch
Incorporating the following units: 1X-F2-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-20 using LRS-75-24 2A Power Supply 2010-SK Scandinavian Key Lock and Key (Applicable to 'SC' variant)
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.11 Delays to outputs 8.4 Total loss of the power supply 10 Test condition Notes: 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch (NL) The Netherlands, 02 French (FR) France , 03 English (UK) United Kingdom and Ireland, 04 German (DE) Germany, 05 Norwegian Norway, 06 Swedish Sweden, 07 Danish (DK) Denmark, 08 English (AU) Australia, 09 Spanish Spain, 10 Italian Italy, 11 Dutch (BE) Belgium, 12 Irish Ireland, 13 German (AU) German (Austria), 14 Greek Greece, 15 Arabic Middle East, 17 English (US) United States of America, 18 Polish Poland, 19 Turkish Turkey, 20 Czech Czech Republic, 21 Portuguese Portugal, 22 Hungarian Hungary, 23 Danish (IC) Iceland, 24 Slovakian Slovak Republic, 25 Russian Russia, 27 Lithuanian Lithuania, 28 Finnish Finland, 29 German (SW) Switzerland, 30 Estonian Estonia, 31 Latvian Latvia, 32 French (BE) Belgium, 33 French (SW) Switzerland, 34 Italian (SW) Switzerland, 36 French (Int) International French, 40 Bulgarian Bulgaria, 41 Belarusian Belarus, 43 Ukrainian Ukraine, 44 Serbian Serbia, 45 Romanian (RO) Romania, 46 German (Int) International German, 48 Croatian Croatia, 49 Macedonian Macedonia, 50 Slovenian Slovenia, 51 Hebrew Israel, 71 Catalan Catalonia (Spain), 80 Chinese China, 99 English (Int) International English |
1199b/01 |
2X-F1, 2X-F1-S | 2X-F1 Intelligent analogue addressable fire panel with user interface- 1 Loop 2X-F1-S Intelligent analogue addressable fire panel with user interface - 1 Loop small cabinet
Incorporating the following units: 2010-2F1-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply
And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2X-D-TP Translucent door option for large cabinet* 2X-D-TP-S Translucent door option for small cabinet* 2010-FS-EOL Fault Supervision End of Line unit
The above fire panels are certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment (not available on 2X-F1 and 2X-F1-S) 7.9.2 Alarm confirmation input from fire alarm routing equipment (not available on 2X-F1 and 2X-F1-S) 7.10 Output to fire protection equipment - Type A,B and C (not available on 2X-F1 and 2X-F1-S) 7.11 Delays to outputs 7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 1. Available with the following language kit options: -01 Dutch (NL) The Netherlands, -02 French (FR), -03 English (UK) United Kingdom and Ireland, -04 German (DE) -05 Norwegian, -06 Swedish, -07 Danish (DK), -08 English (AU) Australia, -09 Spanish, -10 Italian, -11 Dutch (BE) Belgium, -12 Irish, -13 German (AU) (Austria), -14 Greek, -15 Arabic, -17 English (US) United States of America, -18 Polish, -19 Turkish, -20 Czech Republic, -21 Portuguese, -22 Hungarian, -23 Danish (IC) Iceland, -24 Slovakian, -25 Russian, -27 Lithuanian, -28 Finnish, -29 German (SW) Switzerland, -30 Estonian,-31 Latvian, -32 French (BE) Belgium, -33 French (SW) Switzerland, -34 Italian (SW) Switzerland, -36 French (Int) International, -40 Bulgarian, -41 Belarusian, -43 Ukrainian, -44 Serbian, -45 Romanian (RO), -46 German (Int) International, -48 Croatian, -49 Macedonian, -50 Slovenian, -51 Hebrew, -71 Catalan, -80 Chinese, -99 English (Int) International English 2. Scope of the approval does not indicate the operation of the network functionality *The translucent door does not meet EN54-2 access level 1 requirements. To meet EN54-2 requirements with the door fitted the following is also required: 3. A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2 part 7.3) 4. A MCP (without program delay) fitted beside the panel to allow overriding of delays (to meet requirements of EN54-2 part 7.11) |
1199a/05 |