Certificate No 1199c-(cl-1) to EN 54-2: 1998 CIE and EN 54-4: 1998 Power Supply
N.B This certificate is to a withdrawn standard. Control and indicating equipment conforming to this standard is not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because control and indicating equipment meeting the withdrawn standard is still requested by some regulators outside of the EU.
Certificate No 1199c to EN 54-2: 1998 CIE and EN 54-4: 1998 Power Supply
N.B This certificate is to a withdrawn standard. Control and indicating equipment conforming to this standard is not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because control and indicating equipment meeting the withdrawn standard is still requested by some regulators outside of the EU.
Product | Description | LPCB Ref. No. |
---|---|---|
ZP3 | 1, 2 and 4 loop analogue addressable control and indicating equipment
Incorporating as modular units:
ZP3-MB2-4L 4 Loop Main board ZP3-MB2-2L 2 Loop Main board ZP3-MB2-1L 1 Loop Main board ZP3-CPU1 CPU board ZP3-DB1 Display board ZP3-ZB50 50 Zone LED board ZP3-CB1 Commissioning key switch board ZP3-PR1 Printer Kit ZP3AB-SCB-D Control bus driver ZP3AB-RL8 Programmable relay output board, 8 way ZP3-AB-MA8 Programmable monitored output board, 8 way ZP3AB-OP24 Programmable transistor output board, 24 way ZP3AB-MIP8 Programmable input board, 8 way ZP3-Xl 230Vac Power supply unit
Approved with the following options from BS EN54 Part 2:
7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 7.12 Co-incidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.4 Total loss of power 8.9 Output to fault routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardised input/output interface |
1199c/01 |
ZPU (Traditional Chinese Language Variant) | 1, 2 and 4 loop analogue addressable control and indicating equipment
Incorporating as modular units:
ZP3-MB2-4L 4 Loop Main board ZP3-MB2-2L 2 Loop Main board ZP3-MB2-1L 1 Loop Main board ZP3-CPU1 CPU board ZP3-DB1 Display board ZP3-ZB50 50 Zone LED board ZP3-CB1 Commissioning key switch board ZP3-PR1 Printer Kit ZP3AB-SCB-D Control bus driver ZP3AB-RL8 Programmable relay output board, 8 way ZP3-AB-MA8 Programmable monitored output board, 8 way ZP3AB-OP24 Programmable transistor output board, 24 way ZP3AB-MIP8 Programmable input board, 8 way ZP3-Xl 230Vac Power supply unit
Approved with the following options from BS EN54 Part 2:
7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 7.12 Co-incidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.4 Total loss of power 8.9 Output to fault routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardised input/output interface |
1199c/01 |