Eurotech Fire Systems Limited

19/20 Stratfield Park
Elettra Avenue
Waterlooville
Hampshire
PO7 7XN
United Kingdom

Tel: +44 (0)203 141 0999 • Fax: +44 (0)239 225 2554
Email: MICHELLE.AGIUS@eurotechfire.com • Web: www.eurotechfire.com


Certificate No 1213b to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 and EN 54-4: 1998 + A1: 2002 + A2:2006


Control and indicating equipment

Product Description LPCB
Ref. No.
510-0108A Odyssey Plus

One loop, 32 Zone analogue addressable control and indicating equipment.

Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)

BRD86DLTB4-A FFP Dual loop termination board (8610)

BRD86FPB5-B FFP Front panel board EN54 (8610)

BRD86MBA4-A FFP Main board LCD (8610)

BRD86MCPU4-B FFP Main 64MB CPU card (8610)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

1213b/01
510-0208A Odyssey Plus

Two loop, 32 Zone analogue addressable control and indicating equipment.

Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)

BRD86DLTB4-A FFP Dual loop termination board (8610)

BRD86FPB5-B FFP Front panel board EN54 (8610)

BRD86MBA4-A FFP Main board LCD (8610)

BRD86MCPU4-B FFP Main 64MB CPU card (8610)

BRD86SCB3-A FFP Slave CPU card (8610)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

1213b/02
510-0308A Odyssey Plus

Three loop, 32 Zone analogue addressable control and indicating equipment

Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)

BRD86DLTB4-A FFP Two Dual loop termination boards (8610)

BRD86FPB5-B FFP Front panel board EN54 (8610)

BRD86MBA4-A FFP Main board LCD (8610)

BRD86MCPU4-B FFP Main 64MB CPU card (8610)

BRD86SCB3-A FFP Two Slave CPU cards (8610)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD86DLTB4-A FFP Dual loop termination board (8610)

BRD86SCB3-A FFP Slave CPU cards (8610)

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)

BRD86DLTB4-A FFP Two Dual loop termination boards (8610)

BRD86FPB5-B FFP Front panel board EN54 (8610)

BRD86MBA4-A FFP Main board LCD (8610)

BRD86MCPU4-B FFP Main 64MB CPU card (8610)

BRD86SCB3-A FFP Two Slave CPU cards (8610)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD86DLTB4-A FFP Dual loop termination board (8610)

BRD86SCB3-A FFP Slave CPU cards (8610)

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

1213b/03
510-0408A Odyssey Plus

Four loop, 32 Zone analogue addressable control and indicating equipment

Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)

BRD86DLTB4-A FFP Two Dual loop termination boards (8610)

BRD86FPB5-B FFP Front panel board EN54 (8610)

BRD86MBA4-A FFP Main board LCD (8610)

BRD86MCPU4-B FFP Main 64MB CPU card (8610)

BRD86SCB3-A FFP Three Slave CPU cards (8610)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD86DLTB4-A FFP Dual loop termination board (8610)

BRD86SCB3-A FFP Slave CPU cards (8610)

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

1213b/04

 

 


 