Ampac Pty Ltd

7 Ledgar Road
Balcatta
6021
Australia

Tel: +618 (9242) 3333 • Fax: +618 (9242) 3334
Email: askellham@ampac.net • Web: www.ampac.net


Certificate No 010m-(cl-1) to EN54-7: 2001 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Certificate No 010aq-(cl-1) to EN 54-5: 2000 + A1: 2002 + LPS 1274: 2005 + LPS 1265: 2004
Certificate No 010bb-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2:2006 & EN 54:17: 2005 & CEA 4021: 2003

Certificate No 010h to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 & CEA 4021:2003


Multi-Sensor/Multi-Criteria Detectors

Product Description LPCB
Ref. No.
55000-885AMP

Analogue addressable multisensor detector (45681-209AMP and 45681-210AMP mounting base)
Approved with Apollo XP95 and S90 digital communication protocols that have been configured for the XP95 multisensor detector in accordance with manufacturer's instructions.

010m/01
58000-305AMP

Analogue addressable CO/heat multisensor detector

(45681-210AMP, standard intelligent mounting base)

Notes:

1.        Approved with the following mode configurations:-

Mode 1                30 ppm with high thermal enhancement (most sensitive)

Mode 2                33 ppm with CO only

Mode 3                40 ppm with low thermal enhancement (nominal sensitivity)

Mode 4                45 ppm with high thermal enhancement (least sensitive)                        

Mode 5                heat onlyA1R

2.        Mode 1 , 3, and 4 are approved to LPS1274:2005 and EN 54-5:2000 + A1: 2002

3.        Mode 2 is approved to LPS 1265:2004

4.        Mode 5 is approved to EN 54-5:2000 + A1:2002

Conditions of approval include;

a)        The 58000-305AMP should only be installed in accordance with the manufacturer's recommendations.

b)        The 58000-305AMP should not be set only as a carbon monoxide fire detector where there is a specific risk of rapid burning/flaming fires.

c)        Refer to technical publication MAN3038-1 for limitations on the use of carbon monoxide fire detection.

010aq/01
SA5100-700AMP

Soteria Analogue Addressable Class A1R Optical Smoke/Heat Detector with Short Circuit Isolator
(SA5000-200AMP and 45681-210AMP bases)

Certified at the following settings:

Mode 1: High sensitivity smoke detector with high heat enhancement

Mode 2: Standard smoke sensitivity only

Mode 3: Medium sensitivity smoke detector with medium heat enhancement

Mode 4: Low sensitivity smoke detector with high heat enhancement

Mode 5: Class A1R heat detector

010bb/01
SA5000-700AMP

Soteria Analogue Addressable Class A1R Optical Smoke/Heat Detector

(SA5000-200AMP and 45681-210AMP bases)

Certified at the following settings:

Mode 1: High sensitivity smoke detector with high heat enhancement

Mode 2: Standard smoke sensitivity only

Mode 3: Medium sensitivity smoke detector with medium heat enhancement

Mode 4: Low sensitivity smoke detector with high heat enhancement

Mode 5: Class A1R heat detector

010be/01
58000-700AMP

Discovery Analogue Addressable Multisensor Detector

(45681-209 and 45681-210 bases)

Notes:

1. Certified at the following settings:

Mode 1 - High sensitivity smoke detector with standard heat enhancement

Mode 2 - Smoke detection only

Mode 3 - Medium sensitivity smoke detector with standard heat enhancement

Mode 4 - Low sensitivity smoke detector with high heat enhancement

Mode 5 - Class A1 heat detector

Also approved in conventional alarm modes 1, 2, 3, 4 and 5

2. Approved with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery multisensor detector in accordance with manufacturer's instructions.

010h/01

 

Bases
45681-209AMP                XP95/Discovery standard deep mounting base
45681-210AMP                XP95 mounting base
SA5000-200AMP               Addressable XPERT 8 mounting base
46581-209               XP95/Discovery standard deep mounting base
45681-210               XP95 Mounting base


 


 