Ampac Pty Ltd

7 Ledgar Road
Balcatta
6021
Australia

Tel: +618 (9242) 3333 • Fax: +618 (9242) 3334
Email: askellham@ampac.net • Web: www.ampac.net


Certificate No 966a to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No 966b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1998 + A1: 2002 + A2: 2006




Product Description LPCB
Ref. No.
LoopSense 8281-0105

One loop, 32 Zone analogue addressable control and indicating equipment.

Incorporating the following units:

BRD82MBA        Main Termination Board

BRD82ZICC        Zone Interface & Control Card

PSU2397                Power Supply Unit

ASS82ZICC        Zone Indicator & LCD Assembly (8210)

        

Certificated with the following options with requirements from EN54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.11        Delay to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3        Fault signal from points

8.9        Output to fault warning routing equipment

9.5        Disablement of each addressable point

10        Test condition

Note:

1.  This product approval does not constitute compliance with the fire detection and

     alarm systems requirements of EN 54-13.

966a/01
LoopSense 8281-0205

Two loop, 32 Zone analogue addressable control and indicating equipment.

Incorporating the following units:

BRD82MBA        Main Termination Board

BRD82ZICC        Zone Interface & Control Card

PSU2397                 Power Supply Unit

8210-0001        2nd loop activation Key

BRD82LSD        Loop Activation Board

ASS82ZICC        Zone Indicator & LCD Assembly (8210)

        

Certificated with the following options with requirements from EN54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.11        Delay to outputs

7.12.1        Dependencies on more than one alarm signal Type A

7.12.2        Dependencies on more than one alarm signal Type B

7.12.3        Dependencies on more than one alarm signal Type C

8.3        Fault signal from points

8.9        Output to fault warning routing equipment

9.5        Disablement of each addressable point

10        Test condition

Note:

1.  This product approval does not constitute compliance with the fire detection and

     alarm systems requirements of EN 54-13.

966a/02
8681-0108 FireFinder Plus

One loop, 32 Zone analogue addressable control and indicating equipment

Incorporating as modular units:

BRD68BPSC4-B FFP Brigade & Power supply control board (8610)

BRD86DLTB4-C FFP Dual loop termination board (8610)

BRD86FPB5-B FFP Front panel board EN54 (8610)

BRD86MBA4-A FFP Main board LCD (8610)

BRD86MCPU4-B FFP Main 64MB CPU card (8610)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/01
8681-0208 FireFinder Plus

Two loop, 32 Zone analogue addressable control and indicating equipment

Incorporating as modular units:

BRD68BPSC4-B FFP Brigade & Power supply control board (8610)

BRD86DLTB4-C FFP Dual loop termination board (8610)

BRD86FPB5-B FFP Front panel board EN54 (8610)

BRD86MBA4-A FFP Main board LCD (8610)

BRD86MCPU4-B FFP Main 64MB CPU card (8610)

BRD86SCB3-A FFP Slave CPU card (8610)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/02
8681-0308 FireFinder Plus

Incorporating as modular units:

BRD68BPSC4-B FFP Brigade & Power supply control board (8610)

BRD86DLTB4-C FFP Two Dual loop termination boards (8610)

BRD86FPB5-B FFP Front panel board EN54 (8610)

BRD86MBA4-A FFP Main board LCD (8610)

BRD86MCPU4-B FFP Main 64MB CPU card (8610)

BRD86SCB3-A FFP Two Slave CPU cards (8610)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/03
8681-0408 FireFinder Plus

Four loop, 32 Zone analogue addressable control and indicating equipment

Incorporating as modular units:

BRD68BPSC4-B    FFP Brigade & Power supply control board (8610)

BRD86DLTB4-C    FFP Two Dual loop termination boards (8610)

BRD86FPB5-B     FFP Front panel board EN54 (8610)

BRD86MBA4-A     FFP Main board LCD (8610)

BRD86MCPU4-B   FFP Main 64MB CPU card (8610)

BRD86SCB3-A      FFP Three Slave CPU cards (8610)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/04
8681-0110 FireFinder Plus

One Loop, Analogue Addressable SP1X Control and Indicating Equipment

Incorporating the following modular units:

BRD86BPSC4-B         FFP Brigade & Power supply control board (8610)

BRD86DLTB4-C         FFP Dual loop termination board (8610)

BRD86FPB5-B         FFP Front panel board EN54 (8610)

BRD86MBA4-A         FFP Main board LCD (8610)

BRD86MCPU4-B         FFP Main 64MB CPU card (8610)

PSU1888         Power supply 5A Slim RS-150-27 (8610)

Optional Modules:

BRD43EZC2-A         8 Zone conventional module (4310)

BRD43ZAMC2-A         32 Zone alarm MIMIC internal card (4310)

BRD86SCB3-A         FFP Slave CPU card (8610)

BRD86NIC1-A        FFP Network Interface Card

BRD43HLI3-A        High Level Interface Card

Certified with the following options with requirements from EN 54-2:

7.8          Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routine equipment

7.11          Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3          Fault signal from points

8.9          Output to fault warning routing equipment

9.5          Disablement of each addressable point

10        Test Condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/05
8681-0210 FireFinder Plus

Two Loop, Analogue Addressable SP1X Control and Indicating Equipment

Incorporating the following modular units:

BRD86BPSC4-B         FFP Brigade & Power supply control board (8610)

BRD86DLTB4-C         FFP Dual loop termination board (8610)

BRD86FPB5-B         FFP Front panel board EN54 (8610)

BRD86MBA4-A         FFP Main board LCD (8610)

BRD86MCPU4-B         FFP Main 64MB CPU card (8610)

PSU1888         Power supply 5A Slim RS-150-27 (8610)

Optional Modules:

BRD43EZC2-A         8 Zone conventional module (4310)

BRD43ZAMC2-A         32 Zone alarm MIMIC internal card (4310)

BRD86SCB3-A         FFP Slave CPU card (8610)

BRD86NIC1-A        FFP Network Interface Card

BRD43HLI3-A        High Level Interface Card

Certified with the following options with requirements from EN 54-2:

7.8          Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routine equipment

7.11          Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3          Fault signal from points

8.9          Output to fault warning routing equipment

9.5          Disablement of each addressable point

10        Test Condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/06
8681-0310 FireFinder Plus

Three Loop, Analogue Addressable SP1X Control and Indicating Equipment

Incorporating the following modular units:

BRD86BPSC4-B         FFP Brigade & Power supply control board (8610)

BRD86DLTB4-C         FFP Dual loop termination board (8610)

BRD86FPB5-B         FFP Front panel board EN54 (8610)

BRD86MBA4-A         FFP Main board LCD (8610)

BRD86MCPU4-B         FFP Main 64MB CPU card (8610)

PSU1888         Power supply 5A Slim RS-150-27 (8610)

Optional Modules:

BRD43EZC2-A         8 Zone conventional module (4310)

BRD43ZAMC2-A         32 Zone alarm MIMIC internal card (4310)

BRD86SCB3-A         FFP Slave CPU card (8610)

BRD86NIC1-A        FFP Network Interface Card

BRD43HLI3-A        High Level Interface Card

Certified with the following options with requirements from EN 54-2:

7.8          Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routine equipment

7.11          Delay to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3          Fault signal from points

8.9          Output to fault warning routing equipment

9.5          Disablement of each addressable point

10        Test Condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/07
8681-0410 FireFinder Plus

TFour Loop, Analogue Addressable SP1X Control and Indicating Equipment

Incorporating the following modular units:

BRD86BPSC4-B         FFP Brigade & Power supply control board (8610)

BRD86DLTB4-C         FFP Dual loop termination board (8610)

BRD86FPB5-B         FFP Front panel board EN54 (8610)

BRD86MBA4-A         FFP Main board LCD (8610)

BRD86MCPU4-B         FFP Main 64MB CPU card (8610)

PSU1888         Power supply 5A Slim RS-150-27 (8610)

Optional Modules:

BRD43EZC2-A         8 Zone conventional module (4310)

BRD43ZAMC2-A         32 Zone alarm MIMIC internal card (4310)

BRD86SCB3-A         FFP Slave CPU card (8610)

BRD86NIC1-A        FFP Network Interface Card

BRD43HLI3-A        High Level Interface Card

Certified with the following options with requirements from EN 54-2:

7.8          Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routine equipment

7.11          Delay to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3          Fault signal from points

8.9          Output to fault warning routing equipment

9.5          Disablement of each addressable point

10        Test Condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/08
8681-0113 FireFinder Plus

One Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment

Incorporating the following modular units:

BRD86FPB5-B         FFP Front panel board EN54 (8610)

BRD86MBA4-A         FFP Main board LCD (8610)

BRD86MCPU4-B         FFP Main 64MB CPU card (8610)

BRD86DLTB4-C        FFP Dual loop termination board (8610)

BRD86BPSC4-B        FFP Bridge and power supply CTRL Board (8610)

PSU1888        Power supply 5A slim RS-150-27 (8610)

Optional Modules:

BRD43EZC2-A         8 Zone conventional module (4310)

BRD43ZAMC2-A         32 Zone alarm MIMIC internal card (4310)

BRD86SCB3-A         FFP Slave CPU card (8610)

BRD86NIC1-A        FFP Network Interface Card

BRD43HLI3-A        High Level Interface Card

Certified with the following options with requirements from EN 54-2:

7.8          Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routine equipment

7.11          Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3          Fault signal from points

8.9          Output to fault warning routing equipment

9.5          Disablement of each addressable point

10        Test Condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/09
8681-0213 FireFinder Plus

Two Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment

Incorporating the following modular units:

BRD86FPB5-B         FFP Front panel board EN54 (8610)

BRD86MBA4-A         FFP Main board LCD (8610)

BRD86MCPU4-B         FFP Main 64MB CPU card (8610)

BRD86DLTB4-C        FFP Dual loop termination board (8610)

BRD86BPSC4-B        FFP Bridge and power supply CTRL Board (8610)

PSU1888        Power supply 5A slim RS-150-27 (8610)

Optional Modules:

BRD43EZC2-A         8 Zone conventional module (4310)

BRD43ZAMC2-A         32 Zone alarm MIMIC internal card (4310)

BRD86SCB3-A         FFP Slave CPU card (8610)

BRD86NIC1-A        FFP Network Interface Card

BRD43HLI3-A              High Level Interface Card

Certified with the following options with requirements from EN 54-2:

7.8          Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routine equipment

7.11          Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3          Fault signal from points

8.9          Output to fault warning routing equipment

9.5          Disablement of each addressable point

10        Test Condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/10
8681-0313 FireFinder Plus

Three Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment

Incorporating the following modular units:

BRD86FPB5-B         FFP Front panel board EN54 (8610)

BRD86MBA4-A         FFP Main board LCD (8610)

BRD86MCPU4-B         FFP Main 64MB CPU card (8610)

BRD86DLTB4-C        FFP Dual loop termination board (8610)

BRD86BPSC4-B        FFP Bridge and power supply CTRL Board (8610)

PSU1888        Power supply 5A slim RS-150-27 (8610)

Optional Modules:

BRD43EZC2-A         8 Zone conventional module (4310)

BRD43ZAMC2-A         32 Zone alarm MIMIC internal card (4310)

BRD86SCB3-A         FFP Slave CPU card (8610)

BRD86NIC1-A        FFP Network Interface Card

BRD43HLI3-A              High Level Interface Card

Certified with the following options with requirements from EN 54-2:

7.8          Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routine equipment

7.11          Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3          Fault signal from points

8.9          Output to fault warning routing equipment

9.5          Disablement of each addressable point

10        Test Condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/11
8681-0413 FireFinder Plus

Four Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment

Incorporating the following modular units:

BRD86FPB5-B         FFP Front panel board EN54 (8610)

BRD86MBA4-A         FFP Main board LCD (8610)

BRD86MCPU4-B         FFP Main 64MB CPU card (8610)

BRD86DLTB4-C        FFP Dual loop termination board (8610)

BRD86BPSC4-B        FFP Bridge and power supply CTRL Board (8610)

PSU1888        Power supply 5A slim RS-150-27 (8610)

Optional Modules:

BRD43EZC2-A         8 Zone conventional module (4310)

BRD43ZAMC2-A         32 Zone alarm MIMIC internal card (4310)

BRD86SCB3-A         FFP Slave CPU card (8610)

BRD86NIC1-A        FFP Network Interface Card

BRD43HLI3-A              High Level Interface Card

Certified with the following options with requirements from EN 54-2:

7.8          Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routine equipment

7.11          Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3          Fault signal from points

8.9          Output to fault warning routing equipment

9.5          Disablement of each addressable point

10        Test Condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/12
8681-0513 FireFinder Plus

Five Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment

Incorporating the following modular units:

BRD86FPB5-B         FFP Front panel board EN54 (8610)

BRD86MBA4-A         FFP Main board LCD (8610)

BRD86MCPU4-B         FFP Main 64MB CPU card (8610)

BRD86DLTB4-C        FFP Dual loop termination board (8610)

BRD86BPSC4-B        FFP Bridge and power supply CTRL Board (8610)

PSU1888        Power supply 5A slim RS-150-27 (8610)

BRD86FEPB3-A        FFP Expansion panel board (8610)

Optional Modules:

BRD43EZC2-A         8 Zone conventional module (4310)

BRD43ZAMC2-A         32 Zone alarm MIMIC internal card (4310)

BRD86SCB3-A         FFP Slave CPU card (8610)

BRD86NIC1-A        FFP Network Interface Card

BRD43HLI3-A              High Level Interface Card

Certified with the following options with requirements from EN 54-2:

7.8          Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routine equipment

7.11          Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3          Fault signal from points

8.9          Output to fault warning routing equipment

9.5          Disablement of each addressable point

10        Test Condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/13
8681-0613 FireFinder Plus

Six Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment

Incorporating the following modular units:

BRD86FPB5-B         FFP Front panel board EN54 (8610)

BRD86MBA4-A         FFP Main board LCD (8610)

BRD86MCPU4-B         FFP Main 64MB CPU card (8610)

BRD86DLTB4-C        FFP Dual loop termination board (8610)

BRD86BPSC4-B        FFP Bridge and power supply CTRL Board (8610)

PSU1888        Power supply 5A slim RS-150-27 (8610)

BRD86FEPB3-A        FFP Expansion panel board (8610)

Optional Modules:

BRD43EZC2-A         8 Zone conventional module (4310)

BRD43ZAMC2-A         32 Zone alarm MIMIC internal card (4310)

BRD86SCB3-A         FFP Slave CPU card (8610)

BRD86NIC1-A        FFP Network Interface Card

BRD43HLI3-A              High Level Interface Card

Certified with the following options with requirements from EN 54-2:

7.8          Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routine equipment

7.11          Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3          Fault signal from points

8.9          Output to fault warning routing equipment

9.5          Disablement of each addressable point

10        Test Condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/14
8681-0713 FireFinder Plus

Seven Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment

Incorporating the following modular units:

BRD86FPB5-B         FFP Front panel board EN54 (8610)

BRD86MBA4-A         FFP Main board LCD (8610)

BRD86MCPU4-B         FFP Main 64MB CPU card (8610)

BRD86DLTB4-C        FFP Dual loop termination board (8610)

BRD86BPSC4-B        FFP Bridge and power supply CTRL Board (8610)

PSU1888        Power supply 5A slim RS-150-27 (8610)

BRD86FEPB3-A        FFP Expansion panel board (8610)

Optional Modules:

BRD43EZC2-A         8 Zone conventional module (4310)

BRD43ZAMC2-A         32 Zone alarm MIMIC internal card (4310)

BRD86SCB3-A         FFP Slave CPU card (8610)

BRD86NIC1-A        FFP Network Interface Card

BRD43HLI3-A              High Level Interface Card

Certified with the following options with requirements from EN 54-2:

7.8          Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routine equipment

7.11          Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3          Fault signal from points

8.9          Output to fault warning routing equipment

9.5          Disablement of each addressable point

10        Test Condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/15
8681-0813 FireFinder Plus

Eight Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment

Incorporating the following modular units:

BRD86FPB5-B         FFP Front panel board EN54 (8610)

BRD86MBA4-A         FFP Main board LCD (8610)

BRD86MCPU4-B         FFP Main 64MB CPU card (8610)

BRD86DLTB4-C        FFP Dual loop termination board (8610)

BRD86BPSC4-B        FFP Bridge and power supply CTRL Board (8610)

PSU1888        Power supply 5A slim RS-150-27 (8610)

BRD86FEPB3-A        FFP Expansion panel board (8610)

Optional Modules:

BRD43EZC2-A         8 Zone conventional module (4310)

BRD43ZAMC2-A         32 Zone alarm MIMIC internal card (4310)

BRD86SCB3-A         FFP Slave CPU card (8610)

BRD86NIC1-A        FFP Network Interface Card

BRD43HLI3-A              High Level Interface Card

Certified with the following options with requirements from EN 54-2:

7.8          Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routine equipment

7.11          Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3          Fault signal from points

8.9          Output to fault warning routing equipment

9.5          Disablement of each addressable point

10        Test Condition

Notes:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

966b/16
13U EvacU Elite

Wall Mounted Voice Alarm Control and Indicating Equipment (VACIE)

Incorporating the following mandatory modules:

BRD63PDB1-A        Power Distribution Board

BRD63ABB1-A        Amplifier Backplane Board

BRD63CPU1-A        Distribution CPU
BRD63GUI1-A        Graphical User Interface Primary

ASS63CPU-NET        EvacU Elite CPU Network incorporating:

BRD63NIC1-A        Network Interface Card

ASS63PSU12M        Primary Power Supply incorporating
BRD63PCC1-A        Power Control Card - Primary

RCB-1600-24        Meanwell Power Supply

Network SFP Modules

OEM3087                     IC SFP VDSL Transceiver Module SFP-V5311-L-O "COPPER"

OEM3088                    IC SFP VDSL Transceiver Module SFP-V5311-L-R "COPPER"

Incorporating the following optional modules:

BRD63ILC1-A        Quad Radial Line Card
BRD63LILC1-A         Dual Loop Line Card

BRD63LPA1-A        Dual 25W Amplifier

BRD63LPA1-B        50W Amplifier

BRD63MIC1-A        Multi-Purpose Interface Card

BRD63MOC1-A        Multi-Purpose Output Card

BRD63GUI1-B        Graphical User Interface Secondary

ASS63PSU12S        Secondary Power Supply incorporating

BRD63PCC1-B        Power Control Card - Secondary

RCB-1600-24        Meanwell Power Supply

Certified with the following options with requirements from EN 54-16:

7.3        Audible warning

7.4        Delays to entering the voice alarm condition

7.5        Phased evacuation

7.6.2        Manual silencing of the voice alarm condition

7.7.2        Manual reset of the voice alarm condition

7.8        Output to fire alarm devices

7.9        Voice alarm condition output

8.3        Indication of faults related to the transmission path to the CIE

8.4        Indication of faults related to voice alarm zones

9        Disabled condition

10        Voice alarm manual control

12        Emergency microphone(s)

Notes:

1.        The ASS63WIPM Primary warden intercom phone,  ASS63WIPS Radial WIP Handset and ASS63LWIP Loop WIP Handset were connected to the VACIE as ancillary equipment to verify the functionality only.

2.         The OEM3095 EVACU Elite SFP Single Mode Single Fibre Side A (SFP-GE-BX, BIDI, 1000Base, 1310TX/1490nmRX, SMF, 10km, LC simplex, DOM) and OEM3096 EVACU Elite SFP Single Mode Single Fibre Side B (SFP-GE-BX, BIDI, 1000Base, 1490TX/1310nmRX, SMF, 10km, LC simplex, DOM) were functionally tested but were not subjected to the environmental and EMC tests.

966c/01
24U EvacU Elite

Floor Mounted Voice Alarm Control and Indicating Equipment (VACIE)


Incorporating the following mandatory modules:

BRD63PDB1-A        Power Distribution Board

BRD63ABB1-A        Amplifier Backplane Board

BRD63CPU1-A        Distribution CPU
BRD63GUI1-A        Graphical User Interface Primary

ASS63CPU-NET         EvacU Elite CPU Network incorporating:

BRD63NIC1-A        Network Interface Card

ASS63PSU12M         Primary Power Supply incorporating
BRD63PCC1-A        Power Control Card - Primary

RCB-1600-24        Meanwell Power Supply

Network SFP Modules

OEM3087                     IC SFP VDSL Transceiver Module SFP-V5311-L-O "COPPER"

OEM3088                    IC SFP VDSL Transceiver Module SFP-V5311-L-R "COPPER"

Incorporating the following optional modules:

BRD63ILC1-A        Quad Radial Line Card
BRD63LILC1-A         Dual Loop Line Card

BRD63LPA1-A        Dual 25W Amplifier

BRD63LPA1-B        50W Amplifier

BRD63MIC1-A        Multi-Purpose Interface Card

BRD63MOC1-A        Multi-Purpose Output Card

BRD63GUI1-B        Graphical User Interface Secondary

ASS63PSU12S         Secondary Power Supply incorporating

BRD63PCC1-B            Power Control Card - Secondary

RCB-1600             Meanwell Power Supply

Certified with the following options with requirements from EN 54-16:

7.3        Audible warning

7.4        Delays to entering the voice alarm condition

7.5        Phased evacuation

7.6.2        Manual silencing of the voice alarm condition

7.7.2        Manual reset of the voice alarm condition

7.8        Output to fire alarm devices

7.9        Voice alarm condition output

8.3        Indication of faults related to the transmission path to the CIE

8.4        Indication of faults related to voice alarm zones

9        Disabled condition

10        Voice alarm manual control

12        Emergency microphone(s)

Notes:

1.        The ASS63WIPM Primary warden intercom phone,  ASS63WIPS Radial WIP Handset and ASS63LWIP Loop WIP Handset were connected to the VACIE as ancillary equipment to verify the functionality only.

2.                 The OEM3095 EVACU Elite SFP Single Mode Single Fibre Side A (SFP-GE-BX, BIDI, 1000Base, 1310TX/1490nmRX, SMF, 10km, LC simplex, DOM) and OEM3096 EVACU Elite SFP Single Mode Single Fibre Side B (SFP-GE-BX, BIDI, 1000Base, 1490TX/1310nmRX, SMF, 10km, LC simplex, DOM) were functionally tested but were not subjected to the environmental and EMC tests.

966c/02
13U EvacU Elite

Wall Mounted Emergency Warning Control and Indicating Equipment (EWCIE) and Emergency Intercom Control and Indicating Equipment (EICIE) (Grade 1)

Incorporating the following mandatory modules:

BRD63PDB1-A        Power Distribution Board

BRD63ABB1-A        Amplifier Backplane Board

BRD63CPU1-A        Distribution CPU

BRD63GUI1-A        Graphical User Interface Primary

ASS63CPU-NET        EvacU Elite CPU Network incorporating:

BRD63NIC1-A        Network Interface Card

ASS63PSU12M         Primary Power Supply incorporating:

BRD63PCC1-A        Power Control Card - Primary

RCB-1600-24        Meanwell Power Supply

Network SFP Modules:

OEM3087        IC SFP VDSL Transceiver Module SFP-V5311-L-O "COPPER"

OEM3088        IC SFP VDSL Transceiver Module SFP-V5311-L-R "COPPER"

Incorporating the following optional modules:

BRD63ILC1-A        Quad Radial Line Card

BRD63LILC1-A         Dual Loop Line Card

BRD63LPA1-A        Dual 25W Amplifier

BRD63LPA1-B        50W Amplifier

BRD63MIC1-A        Multi-Purpose Interface Card

BRD63MOC1-A        Multi-Purpose Output Card

BRD63GUI1-B        Graphical User Interface Secondary

ASS63WIPM         Primary Warden Intercom Phone

ASS63PSU12S         Secondary Power Supply incorporating

BRD63PCC1-B        Power Control Card - Secondary

RCB-1600-24        Meanwell Power Supply

Certified with the following options with requirements from AS4428.16:2020:

7.2         Indication of alarm signals

7.3        Alert signal

7.6        Audible indication of alarm signal reception

7.7        Delays before entering the emergency warning condition

7.8        Phased Evacuation with Multi-Zone System

7.9.2        Silencing of the emergency warning condition with a manual         control

7.10.2        Reset of emergency warning condition with a manual         condition

7.11        Output to Warning devices

7.12        Emergency warning condition output signal

9        Disabled condition

10        Test Condition

11        Automatic/Manual Mode

11.2         Manual Control of Networked EWCIE

12.1        Individual emergency zone controls

12.2        All emergency zone controls

14        Emergency Microphone
14.2         Ready-to-Talk Indicator

18.9        Dry heat, steady state test (operational) 50°±2°C

Certified with the following options with requirements from AS7240.4:2018:

6.8        Impact (operational)         

6.9        Vibration, sinusoidal (operational)         

6.12        Vibration, sinusoidal (endurance)        

6.13        Dry heat (operational) 50°±2°C

Certified with the following options with requirements from AS4428.4:2016:

8.8        External silencing of the EICIE Fault Condition        

9        Zone cleared condition         

10        Manual control of networked EICIE

11.2        WIP group call control                

16.6        Dry heat, steady state test (operational) 50°±2°C

Notes:

1.        The Emergency warning control and indicating equipment (EWCIE) meets grade 1. The EWCIE is capable of meeting certain optional functions but for grade 1, these must not be enabled.

2.        The ASS63WIPS Radial WIP Handset and ASS63LWIP  Loop WIP Handset were connected to the EICIE as ancillary equipment to verify the functionality only.  These modules were not subjected to  the environmental and EMC tests.

3.          The OEM3095 EVACU Elite SFP Single Mode Single Fibre Side A  (SFP-GE-BX, BIDI, 1000Base, 1310TX/1490nmRX, SMF, 10km, LC simplex, DOM) and OEM3096 EVACU Elite SFP Single Mode Single Fibre Side B (SFP-GE-BX, BIDI, 1000Base, 1490TX/1310nmRX, SMF, 10km, LC simplex, DOM) were functionaly tested but were not subjcetd to the environmental and EMC tests.

966d/01
24U EvacU Elite

Floor Mounted Emergency Warning Control and Indicating equipment (EWCIE) and Emergency Intercom Control and Indicating Equipment (EICIE) (Grade 1)


Incorporating the following mandatory modules:

BRD63PDB1-A        Power Distribution Board

BRD63ABB1-A        Amplifier Backplane Board

BRD63CPU1-A        Distribution CPU

BRD63GUI1-A        Graphical User Interface Primary

ASS63CPU-NET        EvacU Elite CPU Network incorporating:

BRD63NIC1-A        Network Interface Card

ASS63PSU12M         Primary Power Supply incorporating

BRD63PCC1-A        Power Control Card - Primary

RCB-1600-24        Meanwell Power Supply

Network SFP Modules

OEM3087                     IC SFP VDSL Transceiver Module SFP-V5311-L-O "COPPER"

OEM3088                    IC SFP VDSL Transceiver Module SFP-V5311-L-R "COPPER"

Incorporating the following optional modules:

BRD63ILC1-A        Quad Radial Line Card

BRD63LILC1-A         Dual Loop Line Card

BRD63LPA1-A        Dual 25W Amplifier

BRD63LPA1-B        50W Amplifier

BRD63MIC1-A        Multi-Purpose Interface Card

BRD63MOC1-A        Multi-Purpose Output Card

BRD63GUI1-B        Graphical User Interface Secondary

ASS63WIPM         Primary Warden Intercom Phone

ASS63PSU12S         Secondary Power Supply incorporating

BRD63PCC1-B           Power Control Card - Secondary

RCB-1600-24        Meanwell Power Supply

Certified with the following options with requirements from AS4428.16:2020:

7.2         Indication of alarm signals

7.3        Alert signal

7.6        Audible indication of alarm signal reception

7.7        Delays before entering the emergency warning condition

7.8        Phased Evacuation with Multi-Zone System

7.9.2        Silencing of the emergency warning condition with a manual control

7.10.2        Reset of emergency warning condition with a manual condition

7.11        Output to Warning devices

7.12        Emergency warning condition output signal

9        Disabled condition

10        Test Condition

11        Automatic/Manual Mode

11.2         Manual Control of Networked EWCIE

12.1        Individual emergency zone controls

12.2        All emergency zone controls

14        Emergency Microphone
14.2         Ready-to-Talk Indicator

18.9        Dry heat, steady state test (operational) 50°±2°C

Certified with the following options with requirements from AS7240.4:2018:

6.8        Impact (operational)         

6.9        Vibration, sinusoidal (operational)         

6.12        Vibration, sinusoidal (endurance)        

6.13        Dry heat (operational) 50°±2°C

Certified with the following options with requirements from AS4428.4:2016:

8.8        External silencing of the EICIE Fault Condition        

9        Zone cleared condition         

10        Manual control of networked EICIE

11.2        WIP group call control                

16.6        Dry heat, steady state test (operational) 50°±2°C

Notes:

1.        The Emergency warning control and indicating equipment (EWCIE) meets grade 1. The EWCIE is capable of meeting certain optional functions but for grade 1, these must not be enabled.

2.         The ASS63WIPS Radial WIP Handset  and ASS63LWIP  Loop WIP Handset were connected to the EICIE as ancillary equipment to verify the functionality only.  These modules were not subjected to  the environmental and EMC tests.

3. The OEM3095 EVACU Elite SFP Single Mode Single Fibre Side A  (SFP-GE-BX, BIDI, 1000Base, 1310TX/1490nmRX, SMF, 10km, LC simplex, DOM) and OEM3096 EVACU Elite SFP Single Mode Single Fibre Side B (SFP-GE-BX, BIDI, 1000Base, 1490TX/1310nmRX, SMF, 10km, LC simplex, DOM) were functionaly tested but were not subjcetd to the environmental and EMC tests.

966d/02

 

 


 

To read the Red Book section introduction click here.

 