7 Ledgar Road
Balcatta
6021
Australia
Tel: +618 (9242) 3333
•
Fax: +618 (9242) 3334
Email: askellham@ampac.net
•
Web: www.ampac.net
Certificate No 966a to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No 966b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1998 + A1: 2002 + A2: 2006
Product | Description | LPCB Ref. No. |
---|---|---|
LoopSense 8281-0105 | One loop, 32 Zone analogue addressable control and indicating equipment.
Incorporating the following units:
BRD82MBA Main Termination Board BRD82ZICC Zone Interface & Control Card PSU2397 Power Supply Unit ASS82ZICC Zone Indicator & LCD Assembly (8210)
Certificated with the following options with requirements from EN54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. |
966a/01 |
LoopSense 8281-0205 | Two loop, 32 Zone analogue addressable control and indicating equipment.
Incorporating the following units:
BRD82MBA Main Termination Board BRD82ZICC Zone Interface & Control Card PSU2397 Power Supply Unit 8210-0001 2nd loop activation Key BRD82LSD Loop Activation Board ASS82ZICC Zone Indicator & LCD Assembly (8210)
Certificated with the following options with requirements from EN54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. |
966a/02 |
8681-0108 FireFinder Plus | One loop, 32 Zone analogue addressable control and indicating equipment
Incorporating as modular units:
BRD68BPSC4-B FFP Brigade & Power supply control board (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) PSU1888 Power supply 5A (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/01 |
8681-0208 FireFinder Plus | Two loop, 32 Zone analogue addressable control and indicating equipment
Incorporating as modular units:
BRD68BPSC4-B FFP Brigade & Power supply control board (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86SCB3-A FFP Slave CPU card (8610) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) PSU1888 Power supply 5A (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/02 |
8681-0308 FireFinder Plus | Incorporating as modular units:
BRD68BPSC4-B FFP Brigade & Power supply control board (8610) BRD86DLTB4-C FFP Two Dual loop termination boards (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86SCB3-A FFP Two Slave CPU cards (8610) PSU1888 Power supply 5A (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/03 |
8681-0408 FireFinder Plus | Four loop, 32 Zone analogue addressable control and indicating equipment
Incorporating as modular units:
BRD68BPSC4-B FFP Brigade & Power supply control board (8610) BRD86DLTB4-C FFP Two Dual loop termination boards (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86SCB3-A FFP Three Slave CPU cards (8610) PSU1888 Power supply 5A (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/04 |
8681-0110 FireFinder Plus | One Loop, Analogue Addressable SP1X Control and Indicating Equipment
Incorporating the following modular units: BRD86BPSC4-B FFP Brigade & Power supply control board (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) PSU1888 Power supply 5A Slim RS-150-27 (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) BRD86SCB3-A FFP Slave CPU card (8610) BRD86NIC1-A FFP Network Interface Card BRD43HLI3-A High Level Interface Card
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test Condition Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/05 |
8681-0210 FireFinder Plus | Two Loop, Analogue Addressable SP1X Control and Indicating Equipment
Incorporating the following modular units:
BRD86BPSC4-B FFP Brigade & Power supply control board (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) PSU1888 Power supply 5A Slim RS-150-27 (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) BRD86SCB3-A FFP Slave CPU card (8610) BRD86NIC1-A FFP Network Interface Card BRD43HLI3-A High Level Interface Card Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test Condition Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/06 |
8681-0310 FireFinder Plus | Three Loop, Analogue Addressable SP1X Control and Indicating Equipment
Incorporating the following modular units:
BRD86BPSC4-B FFP Brigade & Power supply control board (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) PSU1888 Power supply 5A Slim RS-150-27 (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) BRD86SCB3-A FFP Slave CPU card (8610) BRD86NIC1-A FFP Network Interface Card BRD43HLI3-A High Level Interface Card
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test Condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/07 |
8681-0410 FireFinder Plus | TFour Loop, Analogue Addressable SP1X Control and Indicating Equipment
Incorporating the following modular units:
BRD86BPSC4-B FFP Brigade & Power supply control board (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) PSU1888 Power supply 5A Slim RS-150-27 (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) BRD86SCB3-A FFP Slave CPU card (8610) BRD86NIC1-A FFP Network Interface Card BRD43HLI3-A High Level Interface Card
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test Condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/08 |
8681-0113 FireFinder Plus | One Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment
Incorporating the following modular units: BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86BPSC4-B FFP Bridge and power supply CTRL Board (8610) PSU1888 Power supply 5A slim RS-150-27 (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) BRD86SCB3-A FFP Slave CPU card (8610) BRD86NIC1-A FFP Network Interface Card BRD43HLI3-A High Level Interface Card
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test Condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/09 |
8681-0213 FireFinder Plus | Two Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment
Incorporating the following modular units: BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86BPSC4-B FFP Bridge and power supply CTRL Board (8610) PSU1888 Power supply 5A slim RS-150-27 (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) BRD86SCB3-A FFP Slave CPU card (8610) BRD86NIC1-A FFP Network Interface Card BRD43HLI3-A High Level Interface Card
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point
10 Test Condition Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/10 |
8681-0313 FireFinder Plus | Three Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment
Incorporating the following modular units: BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86BPSC4-B FFP Bridge and power supply CTRL Board (8610) PSU1888 Power supply 5A slim RS-150-27 (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) BRD86SCB3-A FFP Slave CPU card (8610) BRD86NIC1-A FFP Network Interface Card BRD43HLI3-A High Level Interface Card
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test Condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/11 |
8681-0413 FireFinder Plus | Four Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment
Incorporating the following modular units: BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86BPSC4-B FFP Bridge and power supply CTRL Board (8610) PSU1888 Power supply 5A slim RS-150-27 (8610) Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) BRD86SCB3-A FFP Slave CPU card (8610) BRD86NIC1-A FFP Network Interface Card BRD43HLI3-A High Level Interface Card
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test Condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/12 |
8681-0513 FireFinder Plus | Five Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment
Incorporating the following modular units: BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86BPSC4-B FFP Bridge and power supply CTRL Board (8610) PSU1888 Power supply 5A slim RS-150-27 (8610) BRD86FEPB3-A FFP Expansion panel board (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) BRD86SCB3-A FFP Slave CPU card (8610) BRD86NIC1-A FFP Network Interface Card BRD43HLI3-A High Level Interface Card
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point
10 Test Condition Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/13 |
8681-0613 FireFinder Plus | Six Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment
Incorporating the following modular units: BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86BPSC4-B FFP Bridge and power supply CTRL Board (8610) PSU1888 Power supply 5A slim RS-150-27 (8610) BRD86FEPB3-A FFP Expansion panel board (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) BRD86SCB3-A FFP Slave CPU card (8610) BRD86NIC1-A FFP Network Interface Card BRD43HLI3-A High Level Interface Card Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test Condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/14 |
8681-0713 FireFinder Plus | Seven Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment
Incorporating the following modular units: BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86BPSC4-B FFP Bridge and power supply CTRL Board (8610) PSU1888 Power supply 5A slim RS-150-27 (8610) BRD86FEPB3-A FFP Expansion panel board (8610) Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) BRD86SCB3-A FFP Slave CPU card (8610) BRD86NIC1-A FFP Network Interface Card BRD43HLI3-A High Level Interface Card
Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point
10 Test Condition Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/15 |
8681-0813 FireFinder Plus | Eight Loop, 64 Zone 5A SP8X Analogue Addressable Control and Indicating Equipment
Incorporating the following modular units: BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86DLTB4-C FFP Dual loop termination board (8610) BRD86BPSC4-B FFP Bridge and power supply CTRL Board (8610) PSU1888 Power supply 5A slim RS-150-27 (8610) BRD86FEPB3-A FFP Expansion panel board (8610)
Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) BRD86SCB3-A FFP Slave CPU card (8610) BRD86NIC1-A FFP Network Interface Card BRD43HLI3-A High Level Interface Card Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test Condition
Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13 |
966b/16 |
13U EvacU Elite | Wall Mounted Voice Alarm Control and Indicating Equipment (VACIE)
Incorporating the following mandatory modules: BRD63PDB1-A Power Distribution Board BRD63ABB1-A Amplifier Backplane Board
BRD63CPU1-A Distribution CPU ASS63CPU-NET EvacU Elite CPU Network incorporating: BRD63NIC1-A Network Interface Card
ASS63PSU12M Primary Power Supply incorporating RCB-1600-24 Meanwell Power Supply
Network SFP Modules OEM3087 IC SFP VDSL Transceiver Module SFP-V5311-L-O "COPPER" OEM3088 IC SFP VDSL Transceiver Module SFP-V5311-L-R "COPPER" Incorporating the following optional modules:
BRD63ILC1-A Quad Radial Line Card BRD63LPA1-A Dual 25W Amplifier BRD63LPA1-B 50W Amplifier BRD63MIC1-A Multi-Purpose Interface Card BRD63MOC1-A Multi-Purpose Output Card BRD63GUI1-B Graphical User Interface Secondary ASS63PSU12S Secondary Power Supply incorporating BRD63PCC1-B Power Control Card - Secondary RCB-1600-24 Meanwell Power Supply
Certified with the following options with requirements from EN 54-16: 7.3 Audible warning 7.4 Delays to entering the voice alarm condition 7.5 Phased evacuation 7.6.2 Manual silencing of the voice alarm condition 7.7.2 Manual reset of the voice alarm condition 7.8 Output to fire alarm devices 7.9 Voice alarm condition output 8.3 Indication of faults related to the transmission path to the CIE 8.4 Indication of faults related to voice alarm zones 9 Disabled condition 10 Voice alarm manual control 12 Emergency microphone(s) Notes:
1. The ASS63WIPM Primary warden intercom phone, ASS63WIPS Radial WIP Handset and ASS63LWIP Loop WIP Handset were connected to the VACIE as ancillary equipment to verify the functionality only. 2. The OEM3095 EVACU Elite SFP Single Mode Single Fibre Side A (SFP-GE-BX, BIDI, 1000Base, 1310TX/1490nmRX, SMF, 10km, LC simplex, DOM) and OEM3096 EVACU Elite SFP Single Mode Single Fibre Side B (SFP-GE-BX, BIDI, 1000Base, 1490TX/1310nmRX, SMF, 10km, LC simplex, DOM) were functionally tested but were not subjected to the environmental and EMC tests. |
966c/01 |
24U EvacU Elite | Floor Mounted Voice Alarm Control and Indicating Equipment (VACIE)
BRD63PDB1-A Power Distribution Board BRD63ABB1-A Amplifier Backplane Board
BRD63CPU1-A Distribution CPU ASS63CPU-NET EvacU Elite CPU Network incorporating: BRD63NIC1-A Network Interface Card
ASS63PSU12M Primary Power Supply incorporating RCB-1600-24 Meanwell Power Supply
Network SFP Modules OEM3087 IC SFP VDSL Transceiver Module SFP-V5311-L-O "COPPER"
OEM3088 IC SFP VDSL Transceiver Module SFP-V5311-L-R "COPPER" Incorporating the following optional modules:
BRD63ILC1-A Quad Radial Line Card BRD63LPA1-A Dual 25W Amplifier BRD63LPA1-B 50W Amplifier BRD63MIC1-A Multi-Purpose Interface Card BRD63MOC1-A Multi-Purpose Output Card BRD63GUI1-B Graphical User Interface Secondary ASS63PSU12S Secondary Power Supply incorporating BRD63PCC1-B Power Control Card - Secondary
RCB-1600 Meanwell Power Supply Certified with the following options with requirements from EN 54-16: 7.3 Audible warning 7.4 Delays to entering the voice alarm condition 7.5 Phased evacuation 7.6.2 Manual silencing of the voice alarm condition 7.7.2 Manual reset of the voice alarm condition 7.8 Output to fire alarm devices 7.9 Voice alarm condition output 8.3 Indication of faults related to the transmission path to the CIE 8.4 Indication of faults related to voice alarm zones 9 Disabled condition 10 Voice alarm manual control 12 Emergency microphone(s) Notes: 1. The ASS63WIPM Primary warden intercom phone, ASS63WIPS Radial WIP Handset and ASS63LWIP Loop WIP Handset were connected to the VACIE as ancillary equipment to verify the functionality only.
2. The OEM3095 EVACU Elite SFP Single Mode Single Fibre Side A (SFP-GE-BX, BIDI, 1000Base, 1310TX/1490nmRX, SMF, 10km, LC simplex, DOM) and OEM3096 EVACU Elite SFP Single Mode Single Fibre Side B (SFP-GE-BX, BIDI, 1000Base, 1490TX/1310nmRX, SMF, 10km, LC simplex, DOM) were functionally tested but were not subjected to the environmental and EMC tests. |
966c/02 |
13U EvacU Elite | Wall Mounted Emergency Warning Control and Indicating Equipment (EWCIE) and Emergency Intercom Control and Indicating Equipment (EICIE) (Grade 1)
Incorporating the following mandatory modules: BRD63PDB1-A Power Distribution Board BRD63ABB1-A Amplifier Backplane Board BRD63CPU1-A Distribution CPU BRD63GUI1-A Graphical User Interface Primary
ASS63CPU-NET EvacU Elite CPU Network incorporating: BRD63NIC1-A Network Interface Card
ASS63PSU12M Primary Power Supply incorporating: BRD63PCC1-A Power Control Card - Primary RCB-1600-24 Meanwell Power Supply
Network SFP Modules: OEM3087 IC SFP VDSL Transceiver Module SFP-V5311-L-O "COPPER" OEM3088 IC SFP VDSL Transceiver Module SFP-V5311-L-R "COPPER"
Incorporating the following optional modules: BRD63ILC1-A Quad Radial Line Card BRD63LILC1-A Dual Loop Line Card BRD63LPA1-A Dual 25W Amplifier BRD63LPA1-B 50W Amplifier BRD63MIC1-A Multi-Purpose Interface Card BRD63MOC1-A Multi-Purpose Output Card BRD63GUI1-B Graphical User Interface Secondary ASS63WIPM Primary Warden Intercom Phone ASS63PSU12S Secondary Power Supply incorporating BRD63PCC1-B Power Control Card - Secondary RCB-1600-24 Meanwell Power Supply
Certified with the following options with requirements from AS4428.16:2020: 7.2 Indication of alarm signals 7.3 Alert signal 7.6 Audible indication of alarm signal reception 7.7 Delays before entering the emergency warning condition 7.8 Phased Evacuation with Multi-Zone System 7.9.2 Silencing of the emergency warning condition with a manual control 7.10.2 Reset of emergency warning condition with a manual condition 7.11 Output to Warning devices 7.12 Emergency warning condition output signal 9 Disabled condition 10 Test Condition 11 Automatic/Manual Mode 11.2 Manual Control of Networked EWCIE 12.1 Individual emergency zone controls 12.2 All emergency zone controls
14 Emergency Microphone 18.9 Dry heat, steady state test (operational) 50°±2°C
Certified with the following options with requirements from AS7240.4:2018: 6.8 Impact (operational) 6.9 Vibration, sinusoidal (operational) 6.12 Vibration, sinusoidal (endurance) 6.13 Dry heat (operational) 50°±2°C
Certified with the following options with requirements from AS4428.4:2016: 8.8 External silencing of the EICIE Fault Condition 9 Zone cleared condition 10 Manual control of networked EICIE 11.2 WIP group call control 16.6 Dry heat, steady state test (operational) 50°±2°C Notes: 1. The Emergency warning control and indicating equipment (EWCIE) meets grade 1. The EWCIE is capable of meeting certain optional functions but for grade 1, these must not be enabled. 2. The ASS63WIPS Radial WIP Handset and ASS63LWIP Loop WIP Handset were connected to the EICIE as ancillary equipment to verify the functionality only. These modules were not subjected to the environmental and EMC tests. 3. The OEM3095 EVACU Elite SFP Single Mode Single Fibre Side A (SFP-GE-BX, BIDI, 1000Base, 1310TX/1490nmRX, SMF, 10km, LC simplex, DOM) and OEM3096 EVACU Elite SFP Single Mode Single Fibre Side B (SFP-GE-BX, BIDI, 1000Base, 1490TX/1310nmRX, SMF, 10km, LC simplex, DOM) were functionaly tested but were not subjcetd to the environmental and EMC tests. |
966d/01 |
24U EvacU Elite | Floor Mounted Emergency Warning Control and Indicating equipment (EWCIE) and Emergency Intercom Control and Indicating Equipment (EICIE) (Grade 1)
BRD63PDB1-A Power Distribution Board BRD63ABB1-A Amplifier Backplane Board BRD63CPU1-A Distribution CPU BRD63GUI1-A Graphical User Interface Primary
ASS63CPU-NET EvacU Elite CPU Network incorporating: BRD63NIC1-A Network Interface Card
ASS63PSU12M Primary Power Supply incorporating BRD63PCC1-A Power Control Card - Primary RCB-1600-24 Meanwell Power Supply
Network SFP Modules OEM3087 IC SFP VDSL Transceiver Module SFP-V5311-L-O "COPPER" OEM3088 IC SFP VDSL Transceiver Module SFP-V5311-L-R "COPPER"
Incorporating the following optional modules: BRD63ILC1-A Quad Radial Line Card BRD63LILC1-A Dual Loop Line Card BRD63LPA1-A Dual 25W Amplifier BRD63LPA1-B 50W Amplifier BRD63MIC1-A Multi-Purpose Interface Card BRD63MOC1-A Multi-Purpose Output Card BRD63GUI1-B Graphical User Interface Secondary ASS63WIPM Primary Warden Intercom Phone ASS63PSU12S Secondary Power Supply incorporating BRD63PCC1-B Power Control Card - Secondary RCB-1600-24 Meanwell Power Supply
Certified with the following options with requirements from AS4428.16:2020: 7.2 Indication of alarm signals 7.3 Alert signal 7.6 Audible indication of alarm signal reception 7.7 Delays before entering the emergency warning condition 7.8 Phased Evacuation with Multi-Zone System 7.9.2 Silencing of the emergency warning condition with a manual control 7.10.2 Reset of emergency warning condition with a manual condition 7.11 Output to Warning devices 7.12 Emergency warning condition output signal 9 Disabled condition 10 Test Condition 11 Automatic/Manual Mode 11.2 Manual Control of Networked EWCIE 12.1 Individual emergency zone controls 12.2 All emergency zone controls
14 Emergency Microphone 18.9 Dry heat, steady state test (operational) 50°±2°C
Certified with the following options with requirements from AS7240.4:2018: 6.8 Impact (operational) 6.9 Vibration, sinusoidal (operational) 6.12 Vibration, sinusoidal (endurance) 6.13 Dry heat (operational) 50°±2°C
Certified with the following options with requirements from AS4428.4:2016: 8.8 External silencing of the EICIE Fault Condition 9 Zone cleared condition 10 Manual control of networked EICIE 11.2 WIP group call control 16.6 Dry heat, steady state test (operational) 50°±2°C Notes: 1. The Emergency warning control and indicating equipment (EWCIE) meets grade 1. The EWCIE is capable of meeting certain optional functions but for grade 1, these must not be enabled. 2. The ASS63WIPS Radial WIP Handset and ASS63LWIP Loop WIP Handset were connected to the EICIE as ancillary equipment to verify the functionality only. These modules were not subjected to the environmental and EMC tests. 3. The OEM3095 EVACU Elite SFP Single Mode Single Fibre Side A (SFP-GE-BX, BIDI, 1000Base, 1310TX/1490nmRX, SMF, 10km, LC simplex, DOM) and OEM3096 EVACU Elite SFP Single Mode Single Fibre Side B (SFP-GE-BX, BIDI, 1000Base, 1490TX/1310nmRX, SMF, 10km, LC simplex, DOM) were functionaly tested but were not subjcetd to the environmental and EMC tests. |
966d/02 |
To read the Red Book section introduction click here.