Certificate No 176b-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1 :2002 + A2:2006
Certificate No 176c-(cl-2) to EN 54-2: 1997 + A1: 2006


Control and indicating equipment

Product Description LPCB
Ref. No.
XFP502/X/CON

Two Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo Protocol, Metal housing

Incorporating the following units:

SPF0501000        Switch mode power supply board

SPF0501201        XFP Apollo 2 Loop, Main motherboard

SPF0501200        Display board "Keypad Display"

Certified with the following options with requirements from EN 54-2:1997

7.8        Output to fire alarm device(s)

7.11        Delays to the actioning of outputs fire alarm devices and fire routing

        equipment

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

7.13        Alarm counter

8.3        Fault signals from points

9.5        Disablement of each address point

10        Test condition

Note:

1.  Scope of approval does not include the operation of the network functionality.

176b/02
XFP501/X/CON

One Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo Protocol, Metal housing

Incorporating the following units:

SPF0501000        Switch mode power supply board

SPF0501211        XFP Apollo 1 Loop, Main motherboard

SPF0501200        Display board "Keypad Display"

Certified with the following options with requirements from EN 54-2:1997

7.8        Output to fire alarm device(s)

7.11         Delays to the actioning of outputs fire alarm devices and fire routing

        equipment

7.12.1         Dependencies on more than one alarm signal - Type A

7.12.2          Dependencies on more than one alarm signal - Type B

7.12.3          Dependencies on more than one alarm signal - Type C

7.13         Alarm counter

8.3         Fault signals from points

9.5         Disablement of each address point

10              Test condition

Note:

1.  Scope of approval does not include the operation of the network functionality.

176b/04
XFP501E/X/CON

One Loop, 16 Zone Analogue addressable control and indicating

equipment using Apollo protocol, Plastic housing

Incorporating the following units:

SPF0702480        Switch mode power supply board

SPF0501101        XFP Apollo 1 Loop, Main motherboard

Certified with the following options with requirements from EN 54-2:1997

7.8        Output to fire alarm device(s)

7.11         Delays to the actioning of outputs fire alarm devices and fire routing

        equipment

7.12.1         Dependencies on more than one alarm signal - Type A

7.12.2          Dependencies on more than one alarm signal - Type B

7.12.3          Dependencies on more than one alarm signal - Type C

7.13         Alarm counter

8.3         Fault signals from points

9.5         Disablement of each address point

10              Test condition

Note:        

1.  Scope of approval does not include the operation of the network functionality.

176b/06
EP203/CON

Conventional three zone "class A" extinguisher control panel under

Context Plus Brand

Incorporating the following units:

SPF0000203        Main extinguisher control

SPF0000212        External relay interface

SPF0003613        Power supply unit

SPF0000214        EP214 terminator

Incorporating as modular units:

EP210S        Remote Status Unit "Surface Mount" optional (See Note 1)

EP211        Economy Status Unit optional (See Note 1)

Certified with the following options with requirements from EN 12094-1:2003

4.17        Delay of extinguishing signal

4.18         Signal representing the flow of extinguishing agent

4.19         Monitoring of the status of components

4.20             Emergency hold device

4.21             Control of flooding time

4.23        Manual only mode

4.26        Triggering of equipment outside the system

4.27        Emergency abort device

4.30        Activation of alarm devices with different signals

Certified with the following options with requirements from EN 54-2:1997

7.8        Output to fire alarm device(s)

7.11         Delays to the auctioning of outputs fire alarm devices

        and fire routing equipment

7.13         Alarm counter

10              Test condition

Note:

1.  Optional Remote Status Unit part No. EP210S & Economy Status Unit part No. EP211

        are not certified meeting the requirements of the standards specified

2.  Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature

        range of -5°C to +40°C.

176c/01
CFP702-4/CON

Two zone conventional control and indicating equipment

Incorporating the units:

SPF0702480        Switch mode power supply unit board

SPF0724851         2 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8                 Output to fire alarm devices(s)

7.11                 Delays to outputs

10                 Test condition

176b/07
CFP704-4/CON

Four zone conventional control and indicating equipment

Incorporating the units:

SPF0702480        Switch mode power supply unit board

SPF0724853         4 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8                 Output to fire alarm devices(s)

7.11                 Delays to outputs

10                 Test condition

176b/08
CFP708-4/CON

Eight zone conventional control and indicating equipment

Incorporating the units:

SPF0702480        Switch mode power supply unit board

SPF0724855         8 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8                 Output to fire alarm devices(s)

7.11                 Delays to outputs

10                 Test condition

176b/09

 

 


 

To read the Red Book section introduction click here.

 