Certificate No 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Product | Description | LPCB Ref. No. |
---|---|---|
XFP502/H | 2 loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housing
Incorporating the following units: SPF0501000 Switch mode power supply board SPF0501202 XFP Hochiki 2 loop, main motherboard SPF0501200 Display board "keypad display"
Optional language variants; XFP502/H/NL Dutch language variant
Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. |
176b/01 |
XFP502/X | 2 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing
Incorporating the following units: SPF0501000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501200 Display board "Keypad display"
Optional language variants; XFP502/X/ES Spanish language variant XFP502/X/FR French language variant XFP502/X/PORT Portuguese language variant XFP502/X/NL Dutch language variant XFP502/X/CZ Czech language variant
Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. |
176b/02 |
XFP501/H | 1 Loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housing
Incorporating the following units: SPF0501000 Switch mode power supply board SPF0501212 XFP Hochiki 1 loop, main motherboard SPF0501200 Display board "Keypad display"
Optional language variants; XFP501/H/NL Dutch language variant
Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. |
176b/03 |
XFP501/X | 1 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing
Incorporating the following units: SPF0501000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501200 Display board "keypad display"
Optional language variants; XFP501/X/ES Spanish language variant XFP501/X/FR French language variant XFP501/X/PORT Portuguese language variant XFP501/X/NL Dutch language variant XFP501/X/CZ Czech language variant
Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. |
176b/04 |
XFP501E/H | 1 Loop, 16 zone analogue addressable control and indicating equipment using Hochiki protocol, plastic housing
Incorporating the following units: SPF0702480 Switch mode power supply board SPF0501102 XFP Hochiki 1 loop, main motherboard
Optional language variants; XFP501E/H/NL Dutch language variant
Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality |
176b/05 |
XFP501E/X | 1 Loop, 16 zone analogue addressable control and indicating equipment using Apollo Protocol, plastic housing
Incorporating the following units: SPF0702480 Switch mode power supply board SPF0501101 XFP Apollo 1 loop, main motherboard
Optional language variants; XFP501E/X/ES Spanish language variant XFP501E/X/FR French language variant XFP501E/X/PORT Portuguese language variant XFP501E/X/NL Dutch language variant XFP501E/X/CZ Czech language variant
Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality |
176b/06 |
CFP702-4 | Two zone conventional control and indicating equipment
Optional language variants; CFP702-4/DE German language variant CFP702-4/ES Spanish language variant CFP702-4/FR French language variant CFP702-4/ICE Icelandic language variant CFP702-4/PORT Portuguese language variant CFP702-4/NL Dutch language variant CFP702-4/CZ Czech language variant CFP702-4/CH Chinese language variant
Optional colour variant; CFP702-4/R Red Box
Incorporating the units:
SPF0702480 Switch mode power supply unit board SPF0724851 2 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition |
176b/07 |
CFP704-4 | Four zone conventional control and indicating equipment
Incorporating the units:
SPF0702480 Switch mode power supply unit board SPF0724853 4 Zone main control board
Optional language variants; CFP704-4/DE German language variant CFP704-4/ES Spanish language variant CFP704-4/FR French language variant CFP704-4/ICE Icelandic language variant CFP704-4/PORT Portuguese language variant CFP704-4/NL Dutch language variant CFP704-4/CZ Czech language variant CFP704-4/CH Chinese language variant
Optional colour variant; CFP704-4/R Red Box
Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition |
176b/08 |
CFP708-4 | Eight zone conventional control and indicating equipment
Incorporating the units:
SPF0702480 Switch mode power supply unit board SPF0724855 8 Zone main control board
Optional language variants; CFP708-4/DE German language variant CFP708-4/ES Spanish language variant CFP708-4/FR French language variant CFP708-4/ICE Icelandic language variant CFP708-4/PORT Portuguese language variant CFP708-4/NL Dutch language variant CFP708-4/CZ Czech language variant CFP708-4/CH Chinese language variant
Optional colour variant; CFP708-4/R Red Box
Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition |
176b/09 |
CFP702-2 | Alarmsense two zone conventional control and indication equipment
Incorporating the following units: SPF0702480 Switch mode power supply unit board SPF0724851 2 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition |
176b/14 |
CFP704-2 | Alarmsense four zone conventional control and indicating equipment
Incorporating the following units: SPF0702480 Switch mode power supply unit board SPF0724853 4 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition |
176b/15 |
CFP708-2 | Alarmsense eight zone conventional control and indicating equipment
Incorporating the following units: SPF0702480 Switch mode power supply unit board SPF0724855 8 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition |
176b/16 |
CFP702E-4 | Two zone conventional control and indicating equipment
Incorporating the units: SPF0702480 Switch mode power supply unit board SPF0724851 2 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs |
176b/17 |
CFP704E-4 | Four zone conventional control and indicating equipment
Incorporating the units: SPF0702480 Switch mode power supply unit board SPF0724853 4 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs |
176b/18 |
CFP708E-4 | Eight zone conventional control and indicating equipment
Incorporating the units: SPF0702480 Switch mode power supply unit board SPF0724855 8 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs |
176b/19 |
XFP501E/CA | 1 Loop 16 Zone Analogue Addressable Control and Indicating Equipment using CAST protocol, plastic housing Incorporating the following modules: SPF0050127 1 Loop Main board SPF0702025 Switch mode power supply board
Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition
Notes:
|
176b/26 |
XFP501/CA | 1 Loop 32 Zone Analogue Addressable Control and Indicating Equipment using CAST protocol, metal housing Incorporating the following modules: SPF0050110 1 Loop Main board SPF0501021 Switch mode power supply board SPF0501199 Display Board
Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition
Notes:
|
176b/27 |
XFP502/CA | 2 Loop 32 Zone Analogue Addressable Control and Indicating Equipment using CAST protocol, metal housing Incorporating the following modules: SPF0050210 2 Loop Main board SPF0501021 Switch mode power supply board SPF0501199 Display Board
Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition
Notes:
|
176b/28 |