Search by Certificate Number

Rockwool Limited

Wern Tarw
Pencoed
Bridgend
Mid Glamorgan
CF35 6NY
United Kingdom

Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302
Email: info@rockwool.co.uk • Web: www.rockwool.co.uk


Certificate No 022b(3) to LPS 1132: Issue 4


Product

Application

Cavity

Width

(mm)

Barrier

Size

(mm)

Fire Resistance

(min)

Integrity

Fire Resistance

(min)

Insulation

LPCB
Ref. No.
Rockwool Firepro™ TCB Cavity Barrier

Masonry/timber

frame and

masonry

cavity walls

50 - 55

65 X 65

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Masonry/timber

frame and

masonry

cavity walls

56 - 65

75 x 75

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Masonry/timber

frame and

masonry

cavity walls

66 - 75

85 x 85

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Masonry/timber

frame and

masonry

cavity walls

76 - 80

90 x 90

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Masonry/timber

frame and

masonry

cavity walls

81 - 90

100 x 100

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Masonry/timber

frame and

masonry

cavity walls

91 - 100

110 x 110

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Masonry/timber

frame and

masonry

cavity walls

101 - 110

120 x 120

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Masonry/timber

frame and

masonry

cavity walls

111 - 120

130 x 130

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Masonry/timber

frame and

masonry

cavity walls

121 - 130

140 x 140

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Masonry/timber

frame and

masonry

cavity walls

131 - 140

150 x 150

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

50 - 55

65 x 65

30

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

56 - 65

75 x 75

30

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

66 - 75

85 x 85

30

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

76 - 80

90 x 90

30

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

81 - 90

100 x 100

30

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

91 - 100

110 x 110

30

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

101 - 110

120 x 120

30

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

111 - 120

130 x 130

30

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

121 - 130

140 x 140

30

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

131 - 140

150 x 150

30

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

50 - 55

75 x 75

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

56 - 65

75 x 75

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

66 - 75

85 x 85

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

76 - 80

90 x 90

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

81 - 90

100 x 100

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

91 - 100

110 x 110

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

101 - 110

120 x 120

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

111 - 120

130 x 130

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

121 - 130

140 x 140

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

131 - 140

150 x 150

60

30

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

81 - 90

100 x 100

60

60

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

91 - 100

110 x 110

60

60

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

101 - 110

120 x 120

60

60

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

111 - 120

130 x 130

60

60

022b/04
Rockwool Firepro™ TCB Cavity Barrier

Timber frame

121 - 130

140 x 140

60

60

022b/04

 

Notes:

  1.  Rockwool FireproTM TCB Cavity Barrier is designed for use between the leaves of a masonry cavity wall, timber frame construction, or between a timber frame inner leaf and masonry outer leaf.
2.  Barriers can be installed vertically or horizontally.
3.  Refer to manufacturer's technical literature for fixing details.

 


 

To read the Red Book section introduction click here.

 