Protec Fire Detection plc

Protec House
Churchill Way
Nelson
Lancashire
BB9 6RT
United Kingdom

Tel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273
Email: sales@protec.co.uk • Web: www.protec.co.uk



Certificate No 201ad to EN 54-2: 1997+A1: 2006 and EN 54-4: 1997+A1: 2002+A2: 2006
Certificate No 201ag to EN 54-2:1997 + A1:2006, EN 54-4:1997 + A1:2002 + A2:2006


Control and indicating equipment

Product Description LPCB
Ref. No.
6400/DCN

Display and Control node

Incorporating the following units:

SF40-855-65E        Display control unit

SF40-811-47E        Local display unit

SF40-821-49E        PF Terminal unit

Certified with the following options with requirements from EN 54: Part 2:

7.8        Output to fire alarm device(s)

7.9.1        Output to fire alarm routing equipment

7.11        Delays to outputs

7.12.3        Dependencies on more than one alarm signal - Type C

7.13        Alarm counter

8.3        Fault signals from points

8.9        Output to fault warning routing equipment

9.5        Disablement of each address point        

10        Test condition

Notes:

  1. This unit does not meet the requirements of EN 54-2 & 4

as a stand alone unit.  It is intended for use as part of the 6400 distributed network fire alarm system.  In order to meet the requirements of

EN 54-2 & 4 the unit must be used in conjunction with the following units:

  • 6400/2LPN 2 Loop processing node and/or 6400/4LPN 4 Loop

        processing node

  • 6400/PSU 8A Power supply with charger

2.        Scope of approval does not include the operation of the network functionality.

201ad/01
6400/2LPN

2 Loop processing node

Incorporating the following units:

SF40-812-48E        SSU

SF40-814-50E        Local IO

SF40-817-53C        Terminal board

SF40-819-55D        6400 Loop terminal board

SF40-818-54        LPN display board

SF40-826-54C        6400 OPTO isolated 485 board

SF40-913-56B        6400 Loop Transmission board

Notes:

1.        This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit.  It is intended for use as part of the 6400 distributed network fire alarm system.  In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units:

  • 6400/DCN Display and Control node
  • 6400/PSU 8A Power supply with charger

2.        Scope of approval does not include the operation of the network functionality.

201ad/02
6400/4LPN

4 Loop processing node

Incorporating the following units:

SF40-812-48E        SSU

SF40-814-50E        Local IO

SF40-817-53C        5400 Terminal board

SF40-819-55D        6400 Loop terminal board

SF40-818-54        LPN display board

SF40-826-54C        6400 OPTO 485 board

SF40-913-56B        6400 Loop Transmission board

Notes:

1.        This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit.  It is intended for use as part of the 6400 distributed network fire alarm system.  In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units:

  • 6400/DCN Display and Control node
  • 6400/PSU 8A Power supply with charger

2.        Scope of approval does not include the operation of the network functionality.

201ad/03
6400/DCN/2LPN

Display and control node plus 2 Loop processing node

Incorporating the following units:

SF40-855-65E        Display control unit

SF40-811-47E        5400 LED display unit

SF40-812-48E        SSU

SF40-814-50E        Local IO

SF40-817-53C        5400 Terminal board

SF40-819-55D        6400 Loop terminal board

SF40-826-54C        6400 OPTO isolated 485 board

SF40-913-56B        6400 Loop Transmission board

Certified with the following options with requirements from EN 54: Part 2:

7.8        Output to fire alarm device(s)

7.9.1        Output to fire alarm routing equipment

7.11        Delays to outputs

7.12.3        Dependencies on more than one alarm signal - Type C

7.13        Alarm counter

8.3        Fault signals from points

8.9        Output to fault warning routing equipment

9.5        Disablement of each address point        

10        Test condition

Notes:

1.        This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit.  It is intended for use as part of the 6400 distributed network fire alarm system.  In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units:

  • 6400/PSU 8A Power supply with charger

2.        Scope of approval does not include the operation of the network functionality.

201ad/04
6400/DCN/4LPN

Display and control node plus 4 Loop processing node

Incorporating the following units:

SF40-855-65E        Display control unit

SF40-811-47E        5400 Local display unit

SF40-812-48E        SSU

SF40-814-50E        Local IO

SF40-817-53C        5400 Terminal board

SF40-819-55D        6400 Loop terminal board

SF40-826-54C        6400 OPTO isolated 485 board

SF40-913-56B        6400 Loop Transmission board

Certified with the following options with requirements from EN 54: Part 2:

7.8        Output to fire alarm device(s)

7.9.1        Output to fire alarm routing equipment

7.11        Delays to outputs

7.12.3        Dependencies on more than one alarm signal - Type C

7.13        Alarm counter

8.3        Fault signals from points

8.9        Output to fault warning routing equipment

9.5        Disablement of each address point        

10        Test condition

Notes:

1.        This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit.  It is intended for use as part of the 6400 distributed network fire alarm system.  In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units:

  • 6400/PSU 8A Power supply with charger

2.        Scope of approval does not include the operation of the network functionality.

201ad/05
6400/PSU

8A Power supply with charger

Incorporating the following units:

SF40-472-48H-3        8A Power supply with charger

Notes:

1.        This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit.  It is intended for use as part of the 6400 distributed network fire alarm system.  In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units:

  • 6400/DCN Display and Control node
  • 6400/2LPN 2 Loop processing node and/or 6400/4LPN 4 Loop processing node

2.        Scope of approval does not include the operation of the network functionality.

3.        Certified to EN 54-4 only.

201ad/06
6301

1 Loop Analogue addressable control and indicating equipment

Incorporating the following units:

SF41-860-52F        Main Board

SF41-850-50C         Terminal Board

SF40-877-65         CP250 Printer Board

31-100-22         Backbox

31-243-36        Inner Plate

62-407-57        Door

04-701-38        Printer Mechanism

SF40-465-43F        Series 9000 Power Supply Unit

31-275-44        Optional external 24 AH battery box

SF40-879-67G        Network Card

Certified with the following options with requirements from EN 54: Part 2:

7.8          Output to fire alarm device(s)

7.9.1          Output to fire alarm routing equipment

7.11          Delays to outputs

7.12.3          Dependencies on more than one alarm signal - Type C

7.13          Alarm counter

8.3          Fault signals from points

9.5          Disablement of each address point        

10          Test condition

Note:

1. Scope of approval does not include the operation of the network functionality.

201ad/07
6302

2 Loop Analogue addressable control and indicating equipment

Incorporating the following units:

SF41-860-52F        Main Board

SF41-850-50C         Terminal Board

SF40-877-65         CP250 Printer Board

31-100-22        Backbox

31-243-36        Inner Plate

62-407-57        Door

04-701-38        Printer Mechanism

SF40-465-43F        Series 9000 Power Supply Unit

31-275-44        Optional external 24 AH battery box

SF40-879-67G        Network Card

Certified with the following options with requirements from EN 54: Part 2

7.8          Output to fire alarm device(s)

7.9.1          Output to fire alarm routing equipment

7.11          Delays to outputs

7.12.3          Dependencies on more than one alarm signal - Type C

7.13          Alarm counter

8.3          Fault signals from points

9.5          Disablement of each address point        

10          Test condition

Note:

1. Scope of approval does not include the operation of the network functionality.

201ad/08
6304

4 Loop Analogue addressable control and indicating equipment

Incorporating the following units:

SF41-860-52F        Main Board

SF41-850-50C         Terminal Board

SF40-877-65         CP250 Printer Board

31-100-22        Backbox

31-243-36        Inner Plate

62-407-57        Door

04-701-38        Printer Mechanism

SF40-465-43F        Series 9000 Power Supply Unit

SF41-913-56B        SMT Dual 6000 Loop Card

31-275-44        Optional external 24 AH battery box

SF40-879-67G        Network Card

Certified with the following options with requirements from EN 54: Part 2:

7.8          Output to fire alarm device(s)

7.9.1          Output to fire alarm routing equipment

7.11          Delays to outputs

7.12.3          Dependencies on more than one alarm signal - Type C

7.13          Alarm counter

8.3          Fault signals from points

9.5          Disablement of each address point        

10          Test condition

Note:

1. Scope of approval does not include the operation of the network functionality.

201ad/09
6500 C.I.E with Internal PSE

Analogue Addressable 1-4 Loops Control and Indicating Equipment with Internal 3A PSE

Incorporating the following units:

WEFA 474         6500 Terminal Board

WEFA 468         System Controller

WEFA 471         IO Controller Card

WEFA 467         Loop Card

WEFA 498         Loop Card (Atmel)

WEFA 469         Display Controller Card

WEFA 486         PSE 9403 3A PSU

Certified with the following Options with requirements from EN 54-2: 1997 + A1: 2006

7.8        Output to fire alarm device(s)

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing  equipment

7.10.1        Output to fire protection equipment (Type A)

7.10.2        Output to fire protection equipment (Type B)

7.10.3        Output to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

7.13        Alarm counter

8.3        Fault signals from points

8.9        Output to fault warning routing equipment

9.5        Disablement of each address point

10        Test condition

Notes:

1.     This product approval does not constitute compliance with the fire detection and alarm system requirements of EN 54-13.

2.     Scope of approval does not include the operation of the network functionality.

3.     This product approval includes compliance with EN 54-2: 1997 + A1: 2006. Clause 13.7b.

201ag/01
6500 C.I.E with External PSE

Analogue Addressable 1-4 Loops Control and Indicating Equipment with External 3A PSE

Incorporating the following units:

WEFA 474         6500 Terminal Board

WEFA 468         System Controller

WEFA 471         IO Controller Card

WEFA 467         Loop Card

WEFA 498         Loop Card (Atmel)

WEFA 469         Display Controller Card

WEFA 486         PSE 9403 3A PSU

Certified with the following Options with requirements from EN 54-2: 1997 + A1: 2006

7.8        Output to fire alarm device(s)

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing  equipment

7.10.1        Output to fire protection equipment (Type A)

7.10.2        Output to fire protection equipment (Type B)

7.10.3        Output to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

7.13        Alarm counter

8.3        Fault signals from points

8.9        Output to fault warning routing equipment

9.5        Disablement of each address point

10           Test condition

Notes:

1.     This product approval does not constitute compliance with the fire detection and alarm system requirements of EN 54-13.

2.     Scope of approval does not include the operation of the network functionality.

3.     This product approval includes compliance with EN 54-2: 1997 + A1: 2006. Clause 13.7b.

201ag/02
6600 C.I.E with Internal PSE

Analogue Addressable 1-4 Loops Control and Indicating Equipment with Internal 8A PSE

Incorporating the following units:

WEFA 466         6600 Terminal Board

WEFA 468         System Controller

WEFA 471         IO Controller Card

WEFA 467         Loop Card

WEFA 498         Loop Card (Atmel)

WEFA 469         Display Controller Card

WEFA 472         PSE 9800EN 8A

Certified with the following Options with requirements from EN 54-2: 1997 + A1: 2006

7.8        Output to fire alarm device(s)

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing  equipment

7.10.1        Output to fire protection equipment (Type A)

7.10.2        Output to fire protection equipment (Type B)

7.10.3        Output to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

7.13        Alarm counter

8.3        Fault signals from points

8.9        Output to fault warning routing equipment

9.5        Disablement of each address point

10           Test condition

Notes:

1.     This product approval does not constitute compliance with the fire detection and alarm system requirements of EN 54-13.

2.      Scope of approval does not include the operation of the network functionality.

3.      This product approval includes compliance with EN 54-2:  1997 + A1: 2006. Clause 13.7b.

201ag/03
6600 C.I.E with External PSE

Analogue Addressable 1-4 Loops Control and Indicating Equipment with External 8A PSE

Incorporating the following units:

WEFA 466         6600 Terminal Board

WEFA 468         System Controller

WEFA 471         IO Controller Card

WEFA 467         Loop Card

WEFA 498         Loop Card (Atmel)

WEFA 469         Display Controller Card

WEFA 472         PSE 9800EN 8A

Certified with the following Options with requirements from EN 54-2: 1997 + A1: 2006

7.8        Output to fire alarm device(s)

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing  equipment

7.10.1        Output to fire protection equipment (Type A)

7.10.2        Output to fire protection equipment (Type B)

7.10.3        Output to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

7.13        Alarm counter

8.3        Fault signals from points

8.9        Output to fault warning routing equipment

9.5        Disablement of each address point

10           Test condition

Notes:

1.      This product approval does not constitute compliance with the fire detection and alarm system requirements of EN 54-13

2.      Scope of approval does not include the operation of the network functionality.

3.      This product approval includes compliance with EN 54-2: 1997 + A1: 2006. Clause 13.7b.

201ag/04

 

 


 