Tyco Fire & Security GmbH

Victor Von Bruns-Strasse 21
Neuhausen am Rheinfall
Schaffhausen
8212
Switzerland

Tel: +44 (0)1462 667700 • Fax: +44 (0)1462 667777
Email: mashbury@tycoint.com • Web: www.tycosafetyproducts-europe.com


Certificate No 681ag-(cl-3) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No 681ag-(cl-2) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No 681ag-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No 681au-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No 681ad-(cl-2) to EN 54-4:1997 + A1:2002 + A2:2006
Certificate No 681ad-(cl-1) to EN 54-4:1997 + A1:2002 + A2:2006
Certificate No 681ap-(cl-1) to EN 54-2:1997 + A1:2006 EN 54-4:1997 + A1:2002 + A2:2006
Certificate No 681an-(cl-1) to EN 54-2:1997 + A1:2006 & EN 54-4:1997 + A1:2002 + A2:2006
Certificate No 681ak-(cl-1) to EN 54-2:1997 + A1:2006 & EN 54-4:1997 + A1:2002 + A2:2006
Certificate No 681af-(cl-2) to EN 54-2: 1997 + A1: 2006 &EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No 681ae-(cl-1) to EN 54-2:1997 + A1:2006 & EN 54-4:1997 + A1:2002 + A2:2006
Certificate No 681ac-(cl-2) to EN 54-4:1997 + A1:2002 + A2:2006
Certificate No 681au-(cl-2) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006


Control and indicating equipment

Product Description LPCB
Ref. No.
Pro16xD

4-16 Loops Analogue Addressable Control & Indicating Equipment

Incorporating the following units:

ProR1DS        Profile Reduced User Interface

PFI800        PROFILE Panel Field Interface Board

PSC400        PROFILE Backplane 4 Slots

PPM800        Profile Panel Mounting Frame

PBB801        PROFILE 5A Power Unit [With BAQ140T24 PSU]

Incorporating the following optional modules:

PNI800        PROFILE Network Interface Slot Card

PCS800        PROFILE Ethernet Switch

POS800-S        Fibre Optic Switch Single Mode

POS800-M        Fibre Optic Switch Multi-Mode

FB800        Fuse board (15 way)

PZ4x        PROFILE 40 Way Zonal Display

PZ8x        PROFILE 80 Way Zonal Display

TUD800        Triggering board for transmission unit

PLX800        PROFILE Loop Expansion Slot Card

PCH800        PROFILE Charger Slot Card

SM3        Serial Interface to FAT

SFK800        PROFILE Swiss Fire Brigade Interface

IOB800        Input/Output Expansion Board

FOM800        Fibre Optic Module

Incorporating the following mechanical parts:

PXB800        PROFILE Ancillary Expansion Box

PxD        Profile Extension Box For Pro32xD

Pro16xBB - Approved for use with the Pro16xD Control & Indicating Equipment

Incorporating the following units:

PFI800        PROFILE Panel Field Interface Board

PSC400        PROFILE Backplane 4 Slots

PPM800        Profile Panel Mounting Frame

PBB801        PROFILE 5A Power Unit [With BAQ140T24 PSU]

Incorporating the following optional modules:

PNI800        PROFILE Network Interface Slot Card

PCS800        PROFILE Ethernet Switch

POS800-S        Fibre Optic Switch Single Mode

POS800-M        Fibre Optic Switch Multi-Mode

FB800        Fuse board (15 way)

TUD800        Triggering board for transmission unit

PLX800        PROFILE Loop Expansion Slot Card

PCH800        PROFILE Charger Slot Card

SM3        Serial Interface to FAT

SFK800        PROFILE Swiss Fire Brigade Interface

IOB800        Input/Output Expansion Board

FOM800        Fibre Optic Module

Incorporating the following mechanical parts:

PXB800        PROFILE Ancillary Expansion Box

PxD        Profile Extension Box For Pro32xD

Certified with the following options with requirements from EN54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire controls for fire protection equipment - Output type A

7.10.2        Outputs to fire controls for fire protection equipment - Output type B

7.10.3        Outputs to fire controls for fire protection equipment - Output type C

7.10.4        Fault monitoring of fire controls for fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

7.13        Alarm counter

8.3        Fault signals from points

8.9        Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Output to standardised input/output interface

681ag/06
Pro32xD

4-32 Loops Analogue Addressable Control & Indicating Equipment

Incorporating the following units:

ProR1DS        Profile Reduced User Interface

PFI800        PROFILE Panel Field Interface Board

PSC800        PROFILE Backplane 6 Slots

PPM800        Profile Panel Mounting Frame

PBB801        PROFILE 5A Power Unit [With BAQ140T24 PSU]

Incorporating the following optional modules:

PNI800        PROFILE Network Interface Slot Card

PCS800        PROFILE Ethernet Switch

POS800-S        Fibre Optic Switch Single Mode

POS800-M        Fibre Optic Switch Multi-Mode

FB800        Fuse board (15 way)

PZ4x        PROFILE 40 Way Zonal Display

PZ8x        PROFILE 80 Way Zonal Display

TUD800        Triggering board for transmission unit

PLX800        PROFILE Loop Expansion Slot Card

PCH800        PROFILE Charger Slot Card

SM3        Serial Interface to FAT

SFK800        PROFILE Swiss Fire Brigade Interface

IOB800        Input/Output Expansion Board

FOM800        Fibre Optic Module

Incorporating the following mechanical parts:

PXB800        PROFILE Ancillary Expansion Box

PxD        Profile Extension Box For Pro32xD


Pro32xBB  - Approved for use with the Pro32xD Control & Indicating Equipment

Incorporating the following units:

PFI800        PROFILE Panel Field Interface Board

PSC800        PROFILE Backplane 6 Slots

PPM800        Profile Panel Mounting Frame

PBB801        PROFILE 5A Power Unit [With BAQ140T24 PSU]

Incorporating the following optional modules:

PNI800        PROFILE Network Interface Slot Card

PCS800        PROFILE Ethernet Switch

POS800-S        Fibre Optic Switch Single Mode

POS800-M        Fibre Optic Switch Multi-Mode

FB800        Fuse board (15 way)

PZ4x        PROFILE 40 Way Zonal Display

PZ8x        PROFILE 80 Way Zonal Display

TUD800        Triggering board for transmission unit

PLX800        PROFILE Loop Expansion Slot Card

PCH800        PROFILE Charger Slot Card

SM3        Serial Interface to FAT

SFK800        PROFILE Swiss Fire Brigade Interface

IOB800        Input/Output Expansion Board

FOM800        Fibre Optic Module

Incorporating the following mechanical parts:

PXB800        PROFILE Ancillary Expansion Box

PxD        Profile Extension Box For Pro32xD

Certified with the following options with requirements from EN54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire controls for fire protection equipment - Output type A

7.10.2        Outputs to fire controls for fire protection equipment - Output type B

7.10.3        Outputs to fire controls for fire protection equipment - Output type C

7.10.4        Fault monitoring of fire controls for fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

7.13        Alarm counter

8.3        Fault signals from points

8.9        Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Output to standardised input/output interface

681ag/07
FC32-1

MZX125.32Z Analogue Addressable Control and Indicating Equipment 1 Loop, 32 Zone (557.200.701)

Incorporating as modular units:

DCM832R        Operator Control / Display Module

CPU800        Main CPU module

FIM801                Field Interface Module

PMM800        Power Supply Monitor

BAQ60T24        Power Supply

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface

Note:

1)        This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

681ag/01
FC64-2

MZX253 Analogue Addressable Control and Indicating Equipment 2 Loop, 64 Zone (557.200.702)

Incorporating as modular units:

DCM864R          Operator Control / Display Module

CPU800          Main CPU module

FIM802         Field Interface Module

PMM800          Power Supply Monitor

BAQ140T24        Power Supply

                

and as optional modular units:

IOB800         Input/Output Expansion Board

                                 

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface  

Note:

1)        This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

681ag/02
FC64-4

MZX253  Analogue Addressable Control and Indicating Equipment 4 Loop, 64 Zone (557.200.703)

Incorporating as modular units:

DCM864R          Operator Control / Display Module

CPU800          Main CPU module

FIM802         Field Interface Module

PMM800          Power Supply Monitor

BAQ140T24        Power Supply

PMM840          Power Supply Monitor

XLM800         Loop Expander Board

and as optional modular units:

IOB800         Input/Output Expansion Board

                                 

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface  

Note:

1)        This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

681ag/03
FC240-2

MZX254  Analogue Addressable Control and Indicating Equipment 2 Loop, 240 Zone (557.200.704)

Incorporating as modular units:

DCM832          Operator Control / Display Module

CPU800          Main CPU module

FIM802         Field Interface Module

PMM800          Power Supply Monitor

BAQ140T24        Power Supply

                        

and as optional modular units:

IOB800         Input/Output Expansion Board

                                 

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface  

Note:

1)        This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

681ag/04
FC240-4

MZX254  Analogue Addressable Control and Indicating Equipment 4 Loop, 240 Zone (557.200.705)

Incorporating as modular units:

DCM832        Operator Control / Display Module

CPU800          Main CPU module

FIM802         Field Interface Module

PMM800          Power Supply Monitor

BAQ140T24        Power Supply

PMM840          Power Supply Monitor

XLM800         Loop Expander Board

and as optional modular units:

IOB800         Input/Output Expansion Board

                                 

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface  

Note:

1)        This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

681ag/05
FC32RA

MZX16R, 32 Zone Repeater Panel (557.200.706)

Approved for use with the 557.200.701 FireClass 32-1 control and indicating equipment

Incorporating as modular units:

DCM832R        Operator Control / Display Module

PMM800          Power Supply Monitor

BAQ60T24        Power Supply

681ag/R01
FC64RA

MZX32R, 64 Zone Repeater Panel (557.200.707)

Approved for use with the 557.200.702 FireClass 64-2 and 557.200.703 FireClass 64-4 control and indicating equipment.

Incorporating as modular units:

DCM864R        Operator Control / Display Module

PMM800          Power Supply Monitor

BAQ60T24        Power Supply

681ag/R02
FC240RA

MZX32R, 240 Zone Repeater Panel (557.200.708)

Approved for use with the 557.200.704 FireClass 240-2 and 557.200.705 FireClass 240-4 control and indicating equipment.

Incorporating as modular units:

DCM832        Operator Control / Display Module

PMM800          Power Supply Monitor

BAQ60T24        Power Supply

681ag/R03
557.200.501.F

MZX125.32Z Analogue Addressable Control and Indicating Equipment 1 Loop, 32 Zone

Incorporating as modular units:

DCM832R        Operator Control / Display Module

CPU800        Main CPU module

FIM801                Field Interface Module

PMM800        Power Supply Monitor

BAQ60T24        Power Supply

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface

Note:

1)        This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

681ag/01
557.200.502.F

MZX253 Analogue Addressable Control and Indicating Equipment 2 Loop, 64 Zone

Incorporating as modular units:

DCM864R          Operator Control / Display Module

CPU800          Main CPU module

FIM802         Field Interface Module

PMM800          Power Supply Monitor

BAQ140T24        Power Supply

                

and as optional modular units:

IOB800         Input/Output Expansion Board

                                 

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface  

Note:

1)        This product approval does not constitute compliance  with the fire detection and alarm systems requirements of EN 54-13.

681ag/02
557.200.508.F4

MZX253  Analogue Addressable Control and Indicating Equipment 4 Loop, 64 Zone

Incorporating as modular units:

DCM864R          Operator Control / Display Module

CPU800          Main CPU module

FIM802         Field Interface Module

PMM800          Power Supply Monitor

BAQ140T24        Power Supply

PMM840          Power Supply Monitor

XLM800         Loop Expander Board

and as optional modular units:

IOB800         Input/Output Expansion Board

                                 

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface  

Note:

1)        This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

681ag/03
557.200.509.F

MZX254  Analogue Addressable Control and Indicating Equipment 2 Loop, 240 Zone

Incorporating as modular units:

DCM832          Operator Control / Display Module

CPU800          Main CPU module

FIM802         Field Interface Module

PMM800          Power Supply Monitor

BAQ140T24        Power Supply

                        

and as optional modular units:

IOB800         Input/Output Expansion Board

                                 

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface  

Note:

1)        This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

681ag/04
557.200.509.F4

MZX254  Analogue Addressable Control and Indicating Equipment 4 Loop, 240 Zone

Incorporating as modular units:

DCM832        Operator Control / Display Module

CPU800          Main CPU module

FIM802         Field Interface Module

PMM800          Power Supply Monitor

BAQ140T24        Power Supply

PMM840          Power Supply Monitor

XLM800         Loop Expander Board

and as optional modular units:

IOB800         Input/Output Expansion Board

                                 

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface  

Note:

1)        This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

681ag/05
557.200.520.F

MZX16R, 32 Zone Repeater Panel

Approved for use with the 557.200.701 FireClass 32-1 control and indicating equipment

Incorporating as modular units:

DCM832R        Operator Control / Display Module

PMM800          Power Supply Monitor

BAQ60T24        Power Supply

681ag/R01
557.200.521.F

MZX32R, 64 Zone Repeater Panel

Approved for use with the 557.200.702 FireClass 64-2 and 557.200.703 FireClass 64-4 control and indicating equipment.

Incorporating as modular units:

DCM864R        Operator Control / Display Module

PMM800          Power Supply Monitor

BAQ60T24        Power Supply

681ag/R02
557.200.521.F1

MZX32R, 240 Zone Repeater Panel

Approved for use with the 557.200.704 FireClass 240-2 and 557.200.705 FireClass 240-4 control and indicating equipment.

Incorporating as modular units:

DCM832        Operator Control / Display Module

PMM800          Power Supply Monitor

BAQ60T24        Power Supply

681ag/R03
Pro215S

1-2 Loops Analogue Addressable Control & Indicating Equipment, Shallow Housing

Incorporating the following units:

PR1DS                Profile User Interface

PFI800                Profile Panel Field Interface Board

PSU (BAQ140T24) Power Supply Unit        

        

Incorporating the following optional units:

ProR1DS        Profile Reduced User Interface

PNI800                Profile Network Interface Slot Card

FOM800        Fibre Optic Module

PCS800        Profile Ethernet switch

FB800                Fuse Board

TUD800                Triggering Board for transmission unit

IOB800                Input/ Output Expansion Board

PS-12170        2x17Ah Batteries

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm device(s)

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment

7.10.1 Output type A

7.10.2 Output type B

7.10.3 Output type C

7.10.4 Fault monitoring of fire protection equipment

7.11 Delays to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

7.13 Alarm counter

8.3 Fault signals from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each address point

10 Test condition

11 Output to standardised input/output interface

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

681au/01
Pro215D

1-2 Loops Analogue Addressable Control & Indicating Equipment, Deep Housing

Incorporating the following units:

PR1DS                Profile User Interface

PFI800                Profile Panel Field Interface Board

PSC400        Profile Backplane 4 Slots

PSU (BAQ140T24) Power Supply Unit        

        

Incorporating the following optional units:

ProR1DS        Profile Reduced User Interface

PNI800                Profile Network Interface Slot Card

FOM800        Fibre Optic Module

PCS800        Profile Ethernet switch

POS800-S        Fibre Optic Switch Single Mode

POS800-M        Fibre Optic Switch Multi Mode

FB800                Fuse Board

CD5.241        DC-DC Converter (24V input and 24V output )

TUD800                Triggering Board for transmission unit

SM3                Serial Interface to FAT

IOB800                Input/ Output Expansion Board

PS-12380        2x38Ah Batteries

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm device(s)

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment

7.10.1 Output type A

7.10.2 Output type B

7.10.3 Output type C

7.10.4 Fault monitoring of fire protection equipment

7.11 Delays to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

7.13 Alarm counter

8.3 Fault signals from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each address point

10 Test condition

11 Output to standardised input/output interface

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

681au/02
Pro815D

4-8 Loops Analogue Addressable Control & Indicating Equipment

Incorporating the following units:

PR1DS                Profile User Interface

PFI800                Profile Panel Field Interface Board

PSC400        Profile Backplane 4 Slots

PSU (BAQ140T24) Power Supply Unit        

        

Incorporating the following optional units:

ProR1DS        Profile Reduced User Interface

PNI800                Profile Network Interface Slot Card

FOM800        Fibre Optic Module

PLX800                Profile Loop Expansion Slot Card

PCS800        Profile Ethernet switch

POS800-S        Fibre Optic Switch Single Mode

POS800-M        Fibre Optic Switch Multi Mode

FB800                Fuse Board

CD5.241        DC-DC Converter (24V input and 24V output )

TUD800                Triggering Board for transmission unit

SM3                Serial Interface to FAT

IOB800                Input/ Output Expansion Board

PS-12380        2x38Ah Batteries

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm device(s)

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment

7.10.1 Output type A

7.10.2 Output type B

7.10.3 Output type C

7.10.4 Fault monitoring of fire protection equipment

7.11 Delays to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

7.13 Alarm counter

8.3 Fault signals from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each address point

10 Test condition

11 Output to standardised input/output interface

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

681au/04
Pro885D

4-8 Loops Analogue Addressable Control & Indicating Equipment

Incorporating the following units:

PR1DS                Profile User Interface

PFI800                Profile Panel Field Interface Board

PSC400        Profile Backplane 4 Slots

PZ8x                80way Zonal Display

PSU (BAQ140T24) Power Supply Unit        

        

Incorporating the following optional units:

ProR1DS        Profile Reduced User Interface

PNI800                Profile Network Interface Slot Card

FOM800        Fibre Optic Module

PLX800                Profile Loop Expansion Slot Card

PCS800        Profile Ethernet switch

POS800-S        Fibre Optic Switch Single Mode

POS800-M        Fibre Optic Switch Multi Mode

FB800                Fuse Board

CD5.241        DC-DC Converter (24V input and 24V output )

TUD800                Triggering Board for transmission unit

SM3                Serial Interface to FAT

IOB800                Input/ Output Expansion Board

PZ4x                40way Zonal Display

PS-12380        2x38Ah Batteries

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm device(s)

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment

7.10.1 Output type A

7.10.2 Output type B

7.10.3 Output type C

7.10.4 Fault monitoring of fire protection equipment

7.11 Delays to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

7.13 Alarm counter

8.3 Fault signals from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each address point

10 Test condition

11 Output to standardised input/output interface

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

681au/05
Pro815D-CH

4-8 Loops Analogue Addressable Control & Indicating Equipment

Incorporating the following units:

PR1DS                Profile User Interface

PFI800                Profile Panel Field Interface Board

PSC400        Profile Backplane 4 Slots

SFK800                Swiss Fire Brigade Interface

PSU (BAQ140T24) Power Supply Unit        

        

Incorporating the following optional units:

ProR1DS        Profile Reduced User Interface

PNI800                Profile Network Interface Slot Card

FOM800        Fibre Optic Module

PLX800                Profile Loop Expansion Slot Card

PCS800        Profile Ethernet switch

POS800-S        Fibre Optic Switch Single Mode

POS800-M        Fibre Optic Switch Multi Mode

FB800                Fuse Board

CD5.241        DC-DC Converter (24V input and 24V output )

TUD800                Triggering Board for transmission unit

SM3                Serial Interface to FAT

IOB800                Input/ Output Expansion Board

PS-12260        2x26Ah Batteries

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm device(s)

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment

7.10.1 Output type A

7.10.2 Output type B

7.10.3 Output type C

7.10.4 Fault monitoring of fire protection equipment

7.11 Delays to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

7.13 Alarm counter

8.3 Fault signals from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each address point

10 Test condition

11 Output to standardised input/output interface

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

681au/06
557.200.530

PSU A17 Addressable 17Ah Power Supply Unit

Notes:

1)      The unit is not intended to supply power to Fire Alarm Control Panels

2)     The maximum lead length for the fault output connection is 3m

681ad/01
557.200.531

PSU A38 Addressable 38Ah Power Supply Unit

Notes:

1)      The unit is not intended to supply power to Fire Alarm Control Panels

2)      The maximum lead length for the fault output connection is 3m

681ad/02
557.200.731

FIRECLASS 1.9A Power Supply Unit

Notes:

1)      The unit is not intended to supply power to Fire Alarm Control Panels

681ad/03
557.200.732

PSU A17 Addressable 17Ah Power Supply Unit

Notes:

1)      The unit is not intended to supply power to Fire Alarm Control Panels

2)      The maximum lead length for the fault output connection is 3m

681ad/01
557.200.733

PSU A38 Addressable 38Ah Power Supply Unit

Notes:

1)      The unit is not intended to supply power to Fire Alarm Control Panels

2)      The maximum lead length for the fault output connection is 3m

681ad/02
557.200.731

FIRECLASS 1.9A Power Supply Unit

Notes:

1)      The unit is not intended to supply power to Fire Alarm Control Panels

681ad /03
MZX-125

Analogue Addressable Control and Indicating Equipment, 1 loop, 16 Zone (557.200.501)

Incorporating as modular units:

DCM816        Operator Control / Display Module

CPU800                Main CPU module

FIM801                Field Interface Module

PMM800        Power Supply Monitor

BAQ60T24        Power Supply

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11         Standardized input/output interface

681ap/01
MZX-250

Analogue Addressable Control and Indicating Equipment, 1 loop, 32 Zone (557.200.502)

Incorporating as modular units:

DCM832                  Operator Control / Display Module

CPU800                  Main CPU module

FIM802                  Field Interface Module (1 loop version Part No. 2605053)

PMM800                  Power Supply Monitor

BAQ140T24                Power Supply

                

and as an optional modular unit:

IOB800                 Input/Output Expansion Board

                

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface        

681ap/02
MZX-251

Analogue Addressable Control and Indicating Equipment, 1 loop, 32 Zone (557.200.503)

Incorporating as modular units:

DCM832                  Operator Control / Display Module

CPU800                  Main CPU module

FIM802                  Field Interface Module (1 loop version Part No. 2605053)

PMM800                  Power Supply Monitor

BAQ140T24                     Power Supply

        

and as an optional modular unit:

IOB800         Input/Output Expansion Board

                

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface        

681ap/03
MZX-250-CH

Analogue Addressable Control and Indicating Equipment, 1 loop, 32 Zone (557.200.504)

Incorporating as modular units:

DCM832          Operator Control / Display Module

CPU800          Main CPU module

FIM802          Field Interface Module (1 loop version Part No. 2605053)

PMM800          Power Supply Monitor

FBF-CH                Swiss Fire Brigade Interface

BAQ140T24        Power Supply

                

and as an  optional modular unit:

IOB800                 Input/Output Expansion Board

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface          

681ap/04
MZX-251-S

Analogue Addressable Control and Indicating Equipment, 1 loop, 32 Zone (557.200.505)

Incorporating as modular units:

DCM832 -S         Operator Control / Display Module (Scandinavian Fire Brigade                                    Interface/key)

CPU800          Main CPU module

FIM802          Field Interface Module (1 loop version Part No. 2605053)

PMM800          Power Supply Monitor

BAQ140T24        Power Supply

                

and as an optional modular unit:

IOB800                 Input/Output Expansion Board

                

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface        

681ap/05
MZX-252

Analogue Addressable Control and Indicating Equipment, 2 loop, 32 Zone (557.200.506

Incorporating as modular units:

DCM832          Operator Control / Display Module

CPU800          Main CPU module

FIM802          Field Interface Module

PMM800          Power Supply Monitor

BAQ140T24        Power Supply

and as an optional modular unit:

IOB800                 Input/Output Expansion Board

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)  

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface

681ap/06
MZX-252-CH

Analogue Addressable Control and Indicating Equipment, 2 loop, 32 Zone (557.200.507)

Incorporating as modular units:

DCM832        Operator Control / Display Module

CPU800          Main CPU module

FIM802          Field Interface Module

PMM800          Power Supply Monitor

FBF-CH                Swiss Fire Brigade Interface

BAQ140T24        Power Supply

and as an optional modular unit:

IOB800                 Input/Output Expansion Board

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface

681ap/07
MZX-253

Analogue Addressable Control and Indicating Equipment, 2-4 loop, 64 Zone (557.200.508)

Incorporating as modular units:

DCM864R          Operator Control / Display Module

CPU800          Main CPU module

FIM802                 Field Interface Module

PMM800          Power Supply Monitor

BAQ140T24        Power Supply

                

and as optional modular units:

IOB800                 Input/Output Expansion Board

PMM840          Power Supply Monitor

XLM800         Loop Expander Board

                

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface  

681ap/08
MZX-254

Analogue Addressable Control and Indicating Equipment, 2-4 loop, 240 Zone (557.200.509)

Incorporating as modular units:

DCM832          Operator Control / Display Module

CPU800          Main CPU module

FIM802          Field Interface Module

PMM800          Power Supply Monitor

BAQ140T24        Power Supply

                

and as optional modular units:

IOB800                 Input/Output Expansion Board

PMM840          Power Supply Monitor

XLM800         Loop Expander Board

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface

681ap/09
MZX-254-S

Analogue Addressable Control and Indicating Equipment, 2-4 loop, 240 Zone (557.200.511)

Incorporating as modular units:

DCM832 -S         Operator Control / Display Module (Scandinavian

                Fire Brigade Interface/key)

CPU800          Main CPU module

FIM802          Field Interface Module

PMM800          Power Supply Monitor

BAQ140T24        Power Supply

                

and as optional modular units:

IOB800                 Input/Output Expansion Board

PMM840          Power Supply Monitor

XLM800         Loop Expander Board

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface  

681ap/10
MZX-254-CH

Analogue Addressable Control and Indicating Equipment, 2-4 loop, 240 Zone (557.200.510)

Incorporating as modular units:

DCM832          Operator Control / Display Module

CPU800          Main CPU module

FIM802          Field Interface Module

PMM800          Power Supply Monitor

BF-CH                Swiss Fire Brigade Interface

BAQ140T24        Power Supply

                

and as optional modular units:

IOB800                 Input/Output Expansion Board

PMM840          Power Supply Monitor

XLM800         Loop Expander Board

Certified with the following options with requirements from EN 54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11        Standardized input/output interface  

681ap/11
MZX-16-R

16 Zone Repeater Panel, (557.200.520)

Approved for use with the MZX-125 Control and Indicating Equipment

Incorporating as modular units:

DCM816        Operator Control / Display Module

PMM800          Power Supply Monitor

BAQ60T24        Power Supply

681ap/R01
MZX-32-R

32 Zone Repeater Panel, (557.200.521)

Approved  for use with the MZX-250, MZX-250-CH, MZX-251, MZX-252 & MZX-252-CH Control and Indicating Equipment

Incorporating as modular units:

DCM832          Operator Control / Display Module

PMM800          Power Supply Monitor

BAQ60T24        Power Supply

681ap/R02
MZX-32-SR

32 Zone Repeater Panel, (557.200.522)

Approved for use with the MZX-251-S Control and Indicating Equipment

Incorporating as modular units:

DCM832-S          Operator Control / Display Module

PMM800          Power Supply Monitor

BAQ60T24        Power Supply

681ap/R03
MZX-64-DR

64 Zone Repeater Panel, (557.200.526)

Approved for use with the MZX-253 Control and Indicating Equipment

Incorporating as modular units:

DCM864R          Operator Control / Display Module

PMM805          Power Supply Monitor (24 VDC)

681ap/R04
MZX-DR

240 Zone Repeater Panel, (557.200.523)

Approved for use with the MZX-254 Control and Indicating Equipment

Incorporating as modular units:

DCM832         Operator Control / Display Module

PMM805          Power Supply Monitor (24 VDC)

681ap/R05
MZX-SDR

240 Zone Repeater Panel, (557.200.524)

Approved for use with the MZX254-S Control and Indicating Equipment

Incorporating as modular units:

DCM832 -S         Operator Control / Display Module (Scandinavian

                     Fire Brigade Interface/key)

PMM805          Power Supply Monitor (24 VDC)

681ap/R06
MZX-CHDR

240 Zone Repeater Panel, (557.200.525)

Approved for use with the MZX-254-CH Control and Indicating Equipment

Incorporating as modular units:

DCM832         Operator Control / Display Module

FBF-CH                Swiss Fire Brigade Interface

PMM805          Power Supply Monitor (24 VDC)

681ap/R07
MX4000

2-8 loop Analogue Addressable Control and Indicating Equipment

Notes:

1)The following product variants are approved -

Finished goods No.   557.200.003, MX4000 1-4 loop CIE, shallow housing

Finished goods No.   557.200.005, MX-BBX battery box, shallow housing

Finished goods No.   557.200.004, MX4000 1-8 loop CIE, deep housing

Finished goods No.   557.200.006, MX-DPBX battery box, deep housing (door                        access)

Finished goods No.   557.200.016, MX-DPBX battery box, deep housing (plain                        cover access)

Finished goods No.   557.200.009, MX4000 1-4 loop, flush housing

Finished goods No.   557.200.019, MX-BBX-F battery box, flush housing        

Incorporating as modular units:

OCM800          Operator Control Module

ODM800          Operator Display Module

CPU800          Main CPU module

FIM802          Field Interface Module "drives 1 or 2 loops"

PSU830          Power Supply Module

and as optional modular units:

XLM800          Expansion Loop Module  "drives 1 or 2 additional loops"

ANN840          40 + 40 LED Annunciator module

ANN880         80 LED Annunciator module

COM820          20 way Status Command Module

MPM800          Multi-Purpose Interface Module

IOB800          Input/Output Expansion Board

FB800            Fuse Board        

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B  dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11         Standardized input/output interface  

681an/01
MXR

Repeater panel is approved for use with the MX4000 Control and Indicating

Notes:

1)The following product variants are approved -

Finished goods No.   557.200.013, MXR-PSU repeater

Finished goods No.   557.200.018, MXR-PSU-F repeater flush housing

Finished goods No.   557.200.012, MXR repeater

Finished goods No.   557.200.017, MXR-F repeater flush housing

Incorporating as modular units:

OCM800 (Operator Control Module)

ODM800 (Operator Display Module)

PSU830 (Power Supply Module)

and as optional modular units:

ANN840 (40 + 40 LED Annunciator)

ANN880 (80 LED Annunciator)

MPM800 (Multi Purpose Interface Module)

IOB800 (Input/Output Expansion Board)

FB800 (Fuse Board)

681an/R01
MX2

1-8 loop Analogue Addressable Control and Indicating Equipment

Notes:

1) The following product variants are approved -

Finished goods No.   557.200.203, MX2-210, 1-4 loop CIE, shallow housing

Finished goods No.   557.200.205, MX2-211, 1-8 loop CIE, deep housing

        

Incorporating as modular units:

DCM800          Operator Control / Display Module

CPU800          Main CPU module

FIM802          Field Interface Module "drives 1 or 2 loops"

PSU830          Power Supply Module

and as optional modular units:

XLM800          Expansion Loop Module  "drives 1 or 2 additional loops"

ANN881         80 LED Annunciator module

MPM800          Multi-Purpose Interface Module

FB800                       Fuse Board

Certified with the following options with requirements from EN 54 Part 2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.10.1        Outputs to fire protection equipment (Type A)

7.10.2        Outputs to fire protection equipment (Type B)

7.10.3        Outputs to fire protection equipment (Type C)

7.10.4        Fault monitoring of fire protection equipment

7.11        Delays to outputs

7.12.1        Dependencies on more than one alarm signal (Type A dependency)

7.12.2        Dependencies on more than one alarm signal (Type B dependency)

7.12.3        Dependencies on more than one alarm signal (Type C dependency)

7.13        Alarm counter

8.3        Fault signals from points

8.9         Output to fault warning routing equipment

9.5        Disablement of addressable points

10        Test condition

11         Standardized input/output interface  

681ak/01
MXR

Repeater Panel is approved for use with the MX2 Control and Indicating Equipment

Notes:

1) The following product variants are approved -

Finished goods No.   557.200.013, MXR-PSU repeater

Finished goods No.   557.200.018, MXR-PSU-F repeater flush housing

Finished goods No.   557.200.012, MXR repeater

Finished goods No.   557.200.017, MXR-F repeater flush housing

Incorporating as modular units:

OCM800 (Operator Control Module)

ODM800 (Operator Display Module)

PSU830 (Power Supply Module)

and as optional modular units:

ANN840 (40 + 40 LED Annunciator)

ANN880 (80 LED Annunciator)

MPM800 (Multi-Purpose Interface Module)

IOB800 (Input/Output Expansion Board)

FB800 (Fuse Board)

681ak/R01
508.031.701

FIRECLASS Duo-CEL, 1 Zone Conventional Control and Indicating Equipment

Incorporating as modular units:

C1694 - 2605501, 1 Zone Motherboard

BAQ-35T24 Power Supply

Certified with the following options from EN 54-2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.12.1        Dependencies on more than one alarm signal - Type A

7.13        Alarm counter

10        Test condition

681af/01
508.031.702

FIRECLASS Duo-CEL, 2 Zone Conventional Control and Indicating Equipment

Incorporating as modular units:

C1694 - 2605502, 2 Zone Motherboard

BAQ-35T24 Power Supply

Certified with the following options from EN 54-2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.12.1        Dependencies on more than one alarm signal - Type A

7.13        Alarm counter

10        Test condition

681af/02
508.031.703

FIRECLASS Duo-CEL, 4 zone Conventional Control and Indicating Equipment

Incorporating as modular units:

C1694 - 2605503,  4 Zone Motherboard

BAQ-35T24 Power Supply

Certified with the following options from EN 54-2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.12.1        Dependencies on more than one alarm signal - Type A

7.13        Alarm counter

10        Test condition

681af/03
508.031.005.xx

MZXC 4 zone Conventional Control and Indicating Equipment

Incorporating as modular units:

C1694 - 2605503,  4 Zone Motherboard

BAQ-35T24 Power Supply

Certified with the following options from EN 54-2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.12.1        Dependencies on more than one alarm signal - Type A

7.13        Alarm counter

10        Test condition

Note:         xx indicates the language option

        Blank = Blank facia overlay

681af/03
508.031.704

FIRECLASS Duo-CEL, 8 Zone Conventional Control and Indicating Equipment

Incorporating as modular units:

C1694 - 2605504, 8 Zone Motherboard

BAQ-35T24 Power Supply

Certified with the following options from EN 54-2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.12.1        Dependencies on more than one alarm signal - Type A

7.13        Alarm counter

10        Test condition

681af/04
508.031.006.xx

MZXC 8 Zone Conventional Control and Indicating Equipment

Incorporating as modular units:

C1694 - 2605504, 8 Zone Motherboard

BAQ-35T24 Power Supply

Certified with the following options from EN 54-2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.12.1        Dependencies on more than one alarm signal - Type A

7.13        Alarm counter

10        Test condition

Note:         xx indicates the language option

        Blank = Blank facia overlay

681af/04
508.031.705

FIRECLASS Duo-CEL, Fire Alarm Repeater (Mains)

Incorporating as modular units:

C1694 - 2605505, Repeater Motherboard

BAQ-35T24 Power Supply

Note: Compatible with 508.031.703 & 508.031.704 panels only

681af/R01
508.031.016.xx

Fire Alarm Repeater (Mains)

Incorporating as modular units:

C1694 - 2605505, Repeater Motherboard

BAQ-35T24 Power Supply

Notes:         

1)  Compatible with 508.031.005.xx & 508.031.006.xx panels.

2)  Also compatible with 508.031.005.xx & 508.031.006.xx twin wire conventional panels on certificate 018r.

3)  xx indicates the language option

        Blank = Blank facia overlay

        EG = English facia overlay

681af/R01
508.031.706

FIRECLASS Duo-CEL, Fire Alarm Repeater (24 VDC).

Incorporating as a modular unit:

C1694 - 2605506, Repeater Motherboard        

Note: Compatible with 508.031.703 & 508.031.704 panels only.

681af/R02
508.031.004.xx

MZXC 2 Zone, Twin Wire Conventional Control and Indicating Equipment

Incorporating as modular units:

C1694 - 2605508, 2 Zone Twin Wire Motherboard

BAQ-35T24 Power Supply

Certified with the following options from EN 54-2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.12.1        Dependencies on more than one alarm signal - Type A

7.13        Alarm counter

10        Test condition

                

Note:         xx indicates the language option

        EG = English facia overlay

681ae/01
508.031.005.xx

MZXC 4 Zone, Twin Wire Conventional Control and Indicating Equipment

Incorporating as modular units:

C1694 - 2605509, 4 Zone Twin Wire Motherboard

BAQ-35T24 Power Supply

Certified with the following options from EN 54-2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.12.1        Dependencies on more than one alarm signal - Type A

7.13        Alarm counter

10        Test condition

                

Note:         xx indicates the language option

        EG = English facia overlay

681ae/02
508.031.006.xx

MZXC 8 Zone Twin Wire Conventional Control and Indicating Equipment

Incorporating as modular units:

C1694 - 2605510, 8 Zone Twin Wire Motherboard

BAQ-35T24 Power Supply

Certified with the following options from EN 54-2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.12.1        Dependencies on more than one alarm signal - Type A

7.13        Alarm counter

10        Test condition

Note:         xx indicates the language option

        EG = English facia overlay

681ae/03
PSU A17

Addressable 17Ah Power Supply Unit

Notes:

1) The unit is not intended to supply power to

    Fire Alarm Control Panels

2) The maximum lead length for the fault output connection is 3m

681ac/01
PSU A38

Addressable 38Ah Power Supply Unit

Notes:

1) The unit is not intended to supply power to

    Fire Alarm Control Panels

2) The maximum lead length for the fault output connection is 3m

681ac/02
FC702S

1-2 Loops Analogue Addressable Control & Indicating Equipment, Shallow Housing (557.200.949)

Incorporating the following units:

PR1DS                Profile User Interface

PFI800                Profile Panel Field Interface Board

PSU (BAQ140T24) Power Supply Unit        

        

Incorporating the following optional units:

ProR1DS        Profile Reduced User Interface

PNI800                Profile Network Interface Slot Card

FOM800        Fibre Optic Module

PCS800        Profile Ethernet switch

FB800                Fuse Board

TUD800                Triggering Board for transmission unit

IOB800                Input/ Output Expansion Board

FBI800                Fire Brigade Interface

PS-12170        2x17Ah Batteries

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm device(s)

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment

7.10.1 Output type A

7.10.2 Output type B

7.10.3 Output type C

7.10.4 Fault monitoring of fire protection equipment

7.11 Delays to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

7.13 Alarm counter

8.3 Fault signals from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each address point

10 Test condition

11 Output to standardised input/output interface

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

681au/01
FC702D

1-2 Loops Analogue Addressable Control & Indicating Equipment, Deep Housing (557.200.950)

Incorporating the following units:

PR1DS                Profile User Interface

PFI800                Profile Panel Field Interface Board

PSC400        Profile Backplane 4 Slots

PSU (BAQ140T24) Power Supply Unit        

        

Incorporating the following optional units:

ProR1DS        Profile Reduced User Interface

PNI800                Profile Network Interface Slot Card

FOM800        Fibre Optic Module

PCS800        Profile Ethernet switch

POS800-S        Fibre Optic Switch Single Mode

POS800-M        Fibre Optic Switch Multi Mode

FB800                Fuse Board

CD5.241        DC-DC Converter (24V input and 24V output )

TUD800                Triggering Board for transmission unit

SM3                Serial Interface to FAT

IOB800                Input/ Output Expansion Board

FBI800                Fire Brigade Interface

PS-12380        2x38Ah Batteries

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm device(s)

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment

7.10.1 Output type A

7.10.2 Output type B

7.10.3 Output type C

7.10.4 Fault monitoring of fire protection equipment

7.11 Delays to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

7.13 Alarm counter

8.3 Fault signals from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each address point

10 Test condition

11 Output to standardised input/output interface

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

681au/02
FC718D

4-8 Loops Analogue Addressable Control & Indicating Equipment (557.200.952)

Incorporating the following units:

PR1DS                Profile User Interface

PFI800                Profile Panel Field Interface Board

PSC400        Profile Backplane 4 Slots

PSU (BAQ140T24) Power Supply Unit        

        

Incorporating the following optional units:

ProR1DS        Profile Reduced User Interface

PNI800                Profile Network Interface Slot Card

FOM800        Fibre Optic Module

PLX800                Profile Loop Expansion Slot Card

PCS800        Profile Ethernet switch

POS800-S        Fibre Optic Switch Single Mode

POS800-M        Fibre Optic Switch Multi Mode

FB800                Fuse Board

CD5.241        DC-DC Converter (24V input and 24V output )

TUD800                Triggering Board for transmission unit

SM3                Serial Interface to FAT

IOB800                Input/ Output Expansion Board

FBI800                Fire Brigade Interface

PS-12380        2x38Ah Batteries

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm device(s)

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment

7.10.1 Output type A

7.10.2 Output type B

7.10.3 Output type C

7.10.4 Fault monitoring of fire protection equipment

7.11 Delays to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

7.13 Alarm counter

8.3 Fault signals from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each address point

10 Test condition

11 Output to standardised input/output interface

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

681au/04
FC708D

4-8 Loops Analogue Addressable Control & Indicating Equipment (557.200.951)

Incorporating the following units:

PR1DS                Profile User Interface

PFI800                Profile Panel Field Interface Board

PSC400        Profile Backplane 4 Slots

PZ8x                80way Zonal Display

PSU (BAQ140T24) Power Supply Unit        

        

Incorporating the following optional units:

ProR1DS        Profile Reduced User Interface

PNI800                Profile Network Interface Slot Card

FOM800        Fibre Optic Module

PLX800                Profile Loop Expansion Slot Card

PCS800        Profile Ethernet switch

POS800-S        Fibre Optic Switch Single Mode

POS800-M        Fibre Optic Switch Multi Mode

FB800                Fuse Board

CD5.241        DC-DC Converter (24V input and 24V output )

TUD800                Triggering Board for transmission unit

SM3                Serial Interface to FAT

IOB800                Input/ Output Expansion Board

PZ4x                40way Zonal Display

FBI800                Fire Brigade Interface

PS-12380        2x38Ah Batteries

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm device(s)

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment

7.10.1 Output type A

7.10.2 Output type B

7.10.3 Output type C

7.10.4 Fault monitoring of fire protection equipment

7.11 Delays to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

7.13 Alarm counter

8.3 Fault signals from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each address point

10 Test condition

11 Output to standardised input/output interface

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

681au/05

 

 


 