Alfanar

3rd Industrial Area
New AL Kharj Road
PO Box 564
Riyadh 11383
Kingdom of Saudi Arabia

Tel: +966 92000 6111 • Fax: +966 11275 6699
Email: ahmed.attia@alfanar.com • Web: www.alfanar.com


Certificate No 1343b to BS 7846:2009 Category F2 and F120, EN60754-2:2014 and IEC 60331-21:1999


Alfanar FIREPROOF (F120) Multi-Core Cables

Product

Nominal csa of

conductor (mm2)

Core

Construction

BS 7846

IEC 60331-21

EN 60754-2

LPCB
Ref. No.
Alfanar FIREPROOF (F120) Multi-core Cables

1.5

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

2.5

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

4.0

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

6.0

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

10

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

16

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

25

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

35

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

50

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

70

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

95

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

120

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

150

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

185

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

240

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

300

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01
Alfanar FIREPROOF (F120) Multi-core Cables

400

2, 3 & 4(1)

F2(2) & F120(3)

Complies(4)

Complies(5)

1343b/01

 

Uo/U 600/1000V

Notes:
1.    Stranded conductors only.
2.    In meeting the requirements of BS 7846:2009 Category F2, the Alfanar FIREPROOF (F120) Multi-core Cables met the requirements for smoke density to EN 61034-2:2005, fire reistance to BS 6387:2013 CWZ and achieved less than 0.5%HCI on the insulation, tapes, filler, bedding and outer covering when tested in accordance with EN 50267-2-1:1999.
3.    In meeting the requirements of BS 7846:2009 Catergory F120, the Alfanar FIREPROOF (F120) Multi-core Cables listed met the requirements for 120 minutes fire resistane to BS 8491:2008.
4.    The Alfanar FIREPROOF (F120) Multi-croe Cables met the requirements of IEC 60331-21:1999 when tested at a temperature of 950°C for a duration of 90mins + 15mins cool down, at a voltage rating of 600V.
5. Tested to general method given in EN 60754-2:2014.

 


 