Search by Certificate Number

Hochiki Europe (UK) Limited

Grosvenor Road
Gillingham Business Park
Gillingham
Kent
ME8 0SA
United Kingdom

Tel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132
Email: info@hochikieurope.com • Web: www.hochikieurope.com

Additional Addresses

All Enquiries to:
Hochiki Europe UK Limited
Grosvenor Road
Gillingham Business Park
Gillingham
Kent
ME8 0SA
United Kingdom

Tel: +44 (0)1634 260131 • Fax: +44 (0)1634 260132

Manufacturing at (Certificate Nos. 117, 117f, 117g, 117h, 117j)
Hochiki Corporation
141-1 Maehara Ejiri
Kakuda-shi
Miyagi 971-15
Japan

Tel: +81 3 3444 4111 • Fax: +81 3 3444 4167
Email: overseas@hochiki.co.jp • Web: www.hochiki.co.jp

Manufacturing at (Certificate Nos. 164, 164g, 164m)
Hochiki Europe (UK) Limited
Grosvenor Road
Gillingham Business Park
Gillingham
Kent
ME8 0SA
United Kingdom

Tel: +44 (01634 260131 • Fax: +44 (0)1634 260132
Email: sales@hochikieurope.com • Web: www.hochikieurope.com

Manufacturing at (Certificate Nos. 358, 358c)
Hochiki America Corporation
7051 Village Drive
Buena Park
California
90621
USA

Tel: +1 714 522 2246 • Fax: +1 714 522 2268
Email: overseas@hochiki.co.jp • Web: www.hochiki.com


Certificate No 117p-(cl-1) to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 + A2:2006, EN 54-26:2015, EN 54-29:2015, EN 54-30:2015, EN 54-31:2015, CEA 4021:2003
Certificate No 164y to EN 54-5:2000 + A1:2002
Certificate No 117f-(cl-2) to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 + A2:2006, CEA 4021:2003




Product Description LPCB
Ref. No.
ATJ-E(WHT)

Intelligent Analogue Addressable Class P Heat Detector

(YBN-R/3, YBN-R/3(SCI), YBO-BS, YBO-BSB2/WL, YBO-BSB2(WHT)/WL, YBO-BSB2/RL and YBO-BSB2(WHT)/RL bases)

Note: Classes A1R, BR, CR, A1S, BS and CS.

164y/01
ATJ-EN

Intelligent Analogue Addressable Class P Heat Detector

(YBN-R/3, YBO-BS, YBO-BSB2/WL, YBO-BSB2(WHT)/WL, YBO-BSB2/RL and YBO-BSB2(WHT)/RL bases)

Note: Classes A1R, BR CR, A1S, BS and CS.

164y/02
ATJ-EN(WHT)

Intelligent Analogue Addressable Class P Heat Detector

(YBN-R/3, YBO-BS, YBO-BSB2/WL, YBO-BSB2(WHT)/WL, YBO-BSB2/RL and YBO-BSB2(WHT)/RL bases)

Note: Classes A1R, BR, CR, A1S, BS and CS.

164y/02
ATJ-E(HFP)

Intelligent Analogue Addressable Class P Heat Detector

(YBN-R/3, YBN-R/3(SCI), YBO-BS, YBO-BSB2(WHT)/WL-HFP and YBO-BSB2(WHT)/RL-HFP bases)

Note: Classes A1R, BR, CR, A1S, BS and CS.

164y/01
ACC-E(WHT)

Intelligent Analogue Addressable Multi-Criteria Detector

(YBN-R/3, YBO-BS, YBN-R/3(SCI), YBO-BSB2/WL, YBO-BSB2(WHT)/WL , YBO-BSB2/RL and YBO-BSB2(WHT)/RL bases)

Note:

Certificated at the following modes:

Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivity

Mode 1 - Optical smoke detector at 2% and 4.5% sensitivity

Mode 2 - Fixed temperature heat detector at class A1 & C

117f/02
ACC-EN

Intelligent Analogue Addressable Multi-Criteria Detector

(YBN-R/3, YBO-BS, YBN-R/3(SCI), YBO-BSB2/WL, YBO-BSB2(WHT)/WL, YBO-BSB2/RL and YBO-BSB2(WHT)/RL bases)

Note:

Certificated at the following modes:

Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivity

Mode 1 - Optical smoke detector at 2% and 4.5% sensitivity

Mode 2 - Fixed temperature heat detector at class A1 & C

117f/03
ACC-EN(WHT)

Intelligent Analogue Addressable Multi-Criteria Detector

(YBN-R/3, YBO-BS, YBN-R/3(SCI), YBO-BSB2/WL, YBO-BSB2(WHT)/WL, YBO-BSB2/RL and YBO-BSB2(WHT)/RL bases)

Note:

Certificated at the following modes:

Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivity

Mode 1 - Optical smoke detector at 2% and 4.5% sensitivity

Mode 2 - Fixed temperature heat detector at class A1 & C

117f/03
ACD-E

Intelligent Analogue Addressable Multi-Criteria Detector (Ivory colour) (YBN-R/3, YBN-R/3(WHT), YBN-R/3(SCI), YBN-R/3(WHT)-SCI, YBO-BS, YBO-BS(WHT), YBO-BSB2/WL, YBO-BSB2(WHT)/WL, YBO-BSB2/RL, YBO-BSB2(WHT)/RL bases)

Notes:

1.   Meets the requirements of EN 54-5, depending on the specific heat mode selected, at Classes A1, A1S, A1R, C, CS, CR

2.   Meets the requirements of EN 54-7, depending on the specific smoke mode selected, at Sensitivity Settings 2% and 4.5%

Modes:

9A*        Smoke/Heat/Co Combine (Default Mode)

9B        Co/Heat combine, Heat (RoR)

80*        Smoke/Heat combine

81        Smoke/Heat combine

82*        Smoke

83        Smoke

87        Heat (FT) Heat (RoR) (Fixed Level 1 - Class A1)

88        Heat (FT) Heat (RoR) (Fixed Level 2 - Class A1R)

89        Heat (FT) (Fixed Level 3 - Class A1S)

8A        Heat (FT) Heat (RoR) (Fixed Level 4 - Class C)

8B        Heat (FT) Heat (RoR) (Fixed Level 5 - Class CR)

8C        Heat (FT) (Fixed Level 6 - Class CS)

8D        Smoke, Co, Heat (FT), Heat (RoR), COHb

8E*        Smoke/Heat Combine, COHb

8F*        Smoke, COHb

93        Heat (FT), Heat (RoR), COHb (Fixed Level 1 - Class A1) +COHb

94        Heat (FT), Heat (RoR), COHb (Fixed Level 2 - Class A1R) +COHb

95        Heat (FT), COHb (Fixed Level 3 - Class A1S) +COHb

96        Heat (FT), Heat (RoR), COHb (Fixed Level 4 - Class C) +COHb

97        Heat (FT), Heat (RoR), COHb (Fixed Level 5 - Class CR) +COHb

98        Heat (FT), COHb (Fixed Level 6 - Class CS) +COHb

99*        Smoke/Heat/CO Combine, Smoke, CO/Heat Combine, Heat (FT), Heat (RoR), COHb

9C        COHb

9D        CO

FT         = Fixed Temperature

RoR        = Rate of Rise

COHb         = Carboxyhemoglobin

* Reduced false alarm function

117p/01
ACD-E(WHT)

Intelligent Analogue Addressable Multi-Criteria Detector (White colour) (YBN-R/3, YBN-R/3(WHT), YBN-R/3(SCI), YBN-R/3(WHT)-SCI, YBO-BS, YBO-BS(WHT), YBO-BSB2/WL, YBO-BSB2(WHT)/WL, YBO-BSB2/RL, YBO-BSB2(WHT)/RL bases)

Notes:

1.   Meets the requirements of EN 54-5, depending on the specific heat mode selected, at Classes A1, A1S, A1R, C, CS, CR

2.   Meets the requirements of EN 54-7, depending on the specific smoke mode selected, at Sensitivity Settings 2% and 4.5%

Modes:

9A*        Smoke/Heat/Co Combine (Default Mode)

9B        Co/Heat combine, Heat (RoR)

80*        Smoke/Heat combine

81        Smoke/Heat combine

82*        Smoke

83        Smoke

87        Heat (FT) Heat (RoR) (Fixed Level 1 - Class A1)

88        Heat (FT) Heat (RoR) (Fixed Level 2 - Class A1R)

89        Heat (FT) (Fixed Level 3 - Class A1S)

8A        Heat (FT) Heat (RoR) (Fixed Level 4 - Class C)

8B        Heat (FT) Heat (RoR) (Fixed Level 5 - Class CR)

8C        Heat (FT) (Fixed Level 6 - Class CS)

8D        Smoke, Co, Heat (FT), Heat (RoR), COHb

8E*        Smoke/Heat Combine, COHb

8F*        Smoke, COHb

93        Heat (FT), Heat (RoR), COHb (Fixed Level 1 - Class A1) +COHb

94        Heat (FT), Heat (RoR), COHb (Fixed Level 2 - Class A1R) +COHb

95        Heat (FT), COHb (Fixed Level 3 - Class A1S) +COHb

96        Heat (FT), Heat (RoR), COHb (Fixed Level 4 - Class C) +COHb

97        Heat (FT), Heat (RoR), COHb (Fixed Level 5 - Class CR) +COHb

98        Heat (FT), COHb (Fixed Level 6 - Class CS) +COHb

99*        Smoke/Heat/CO Combine, Smoke, CO/Heat Combine, Heat (FT), Heat (RoR), COHb

9C        COHb

9D        CO

FT         = Fixed Temperature

RoR        = Rate of Rise

COHb         = Carboxyhemoglobin

* Reduced false alarm function

117p/01
ACD-E(HFP)

Intelligent Analogue Addressable Multi-Criteria Detector (White colour) (YBN-R/3, YBN-R/3(WHT), YBN-R/3(SCI), YBN-R/3(WHT)-SCI, YBO-BS, YBO-BS(WHT), YBO-BSB2/WL, YBO-BSB2(WHT)/WL, YBO-BSB2/RL, YBO-BSB2(WHT)/RL bases)

Notes:

1.   Meets the requirements of EN 54-5, depending on the specific heat mode selected, at Classes A1, A1S, A1R, C, CS, CR

2.   Meets the requirements of EN 54-7, depending on the specific smoke mode selected, at Sensitivity Settings 2% and 4.5%

Modes:

9A*        Smoke/Heat/Co Combine (Default Mode)

9B        Co/Heat combine, Heat (RoR)

80*        Smoke/Heat combine

81        Smoke/Heat combine

82*        Smoke

83        Smoke

87        Heat (FT) Heat (RoR) (Fixed Level 1 - Class A1)

88        Heat (FT) Heat (RoR) (Fixed Level 2 - Class A1R)

89        Heat (FT) (Fixed Level 3 - Class A1S)

8A        Heat (FT) Heat (RoR) (Fixed Level 4 - Class C)

8B        Heat (FT) Heat (RoR) (Fixed Level 5 - Class CR)

8C        Heat (FT) (Fixed Level 6 - Class CS)

8D        Smoke, Co, Heat (FT), Heat (RoR), COHb

8E*        Smoke/Heat Combine, COHb

8F*        Smoke, COHb

93        Heat (FT), Heat (RoR), COHb (Fixed Level 1 - Class A1) +COHb

94        Heat (FT), Heat (RoR), COHb (Fixed Level 2 - Class A1R) +COHb

95        Heat (FT), COHb (Fixed Level 3 - Class A1S) +COHb

96        Heat (FT), Heat (RoR), COHb (Fixed Level 4 - Class C) +COHb

97        Heat (FT), Heat (RoR), COHb (Fixed Level 5 - Class CR) +COHb

98        Heat (FT), COHb (Fixed Level 6 - Class CS) +COHb

99*        Smoke/Heat/CO Combine, Smoke, CO/Heat Combine, Heat (FT), Heat (RoR), COHb

9C        COHb

9D        CO

FT         = Fixed Temperature

RoR        = Rate of Rise

COHb         = Carboxyhemoglobin

* Reduced false alarm function

117p/01
ACD-EN

Intelligent Analogue Addressable Multi-Criteria Detector (Ivory colour) (YBN-R/3, YBN-R/3(WHT), YBN-R/3(SCI), YBN-R/3(WHT)-SCI, YBO-BS, YBO-BS(WHT), YBO-BSB2/WL, YBO-BSB2(WHT)/WL, YBO-BSB2/RL, YBO-BSB2(WHT)/RL bases)

Notes:

1.   Meets the requirements of EN 54-5, depending on the specific heat mode selected, at Classes A1, A1S, A1R, C, CS, CR

2.   Meets the requirements of EN 54-7, depending on the specific smoke mode selected, at Sensitivity Settings 2% and 4.5%

Modes:

9A*        Smoke/Heat/Co Combine (Default Mode)

9B        Co/Heat combine, Heat (RoR)

80*        Smoke/Heat combine

81        Smoke/Heat combine

82*        Smoke

83        Smoke

87        Heat (FT) Heat (RoR) (Fixed Level 1 - Class A1)

88        Heat (FT) Heat (RoR) (Fixed Level 2 - Class A1R)

89        Heat (FT) (Fixed Level 3 - Class A1S)

8A        Heat (FT) Heat (RoR) (Fixed Level 4 - Class C)

8B        Heat (FT) Heat (RoR) (Fixed Level 5 - Class CR)

8C        Heat (FT) (Fixed Level 6 - Class CS)

8D        Smoke, Co, Heat (FT), Heat (RoR), COHb

8E*        Smoke/Heat Combine, COHb

8F*        Smoke, COHb

93        Heat (FT), Heat (RoR), COHb (Fixed Level 1 - Class A1) +COHb

94        Heat (FT), Heat (RoR), COHb (Fixed Level 2 - Class A1R) +COHb

95        Heat (FT), COHb (Fixed Level 3 - Class A1S) +COHb

96        Heat (FT), Heat (RoR), COHb (Fixed Level 4 - Class C) +COHb

97        Heat (FT), Heat (RoR), COHb (Fixed Level 5 - Class CR) +COHb

98        Heat (FT), COHb (Fixed Level 6 - Class CS) +COHb

99*        Smoke/Heat/CO Combine, Smoke, CO/Heat Combine, Heat (FT), Heat (RoR), COHb

9C        COHb

9D        CO

FT         = Fixed Temperature

RoR        = Rate of Rise

COHb         = Carboxyhemoglobin

* Reduced false alarm function

117p/02
ACD-EN(WHT)

Intelligent Analogue Addressable Multi-Criteria Detector (White colour) (YBN-R/3, YBN-R/3(WHT), YBN-R/3(SCI), YBN-R/3(WHT)-SCI, YBO-BS, YBO-BS(WHT), YBO-BSB2/WL, YBO-BSB2(WHT)/WL, YBO-BSB2/RL, YBO-BSB2(WHT)/RL bases)

Notes:

1.   Meets the requirements of EN 54-5, depending on the specific heat mode selected, at Classes A1, A1S, A1R, C, CS, CR

2.   Meets the requirements of EN 54-7, depending on the specific smoke mode selected, at Sensitivity Settings 2% and 4.5%

Modes:

9A*        Smoke/Heat/Co Combine (Default Mode)

9B        Co/Heat combine, Heat (RoR)

80*        Smoke/Heat combine

81        Smoke/Heat combine

82*        Smoke

83        Smoke

87        Heat (FT) Heat (RoR) (Fixed Level 1 - Class A1)

88        Heat (FT) Heat (RoR) (Fixed Level 2 - Class A1R)

89        Heat (FT) (Fixed Level 3 - Class A1S)

8A        Heat (FT) Heat (RoR) (Fixed Level 4 - Class C)

8B        Heat (FT) Heat (RoR) (Fixed Level 5 - Class CR)

8C        Heat (FT) (Fixed Level 6 - Class CS)

8D        Smoke, Co, Heat (FT), Heat (RoR), COHb

8E*        Smoke/Heat Combine, COHb

8F*        Smoke, COHb

93        Heat (FT), Heat (RoR), COHb (Fixed Level 1 - Class A1) +COHb

94        Heat (FT), Heat (RoR), COHb (Fixed Level 2 - Class A1R) +COHb

95        Heat (FT), COHb (Fixed Level 3 - Class A1S) +COHb

96        Heat (FT), Heat (RoR), COHb (Fixed Level 4 - Class C) +COHb

97        Heat (FT), Heat (RoR), COHb (Fixed Level 5 - Class CR) +COHb

98        Heat (FT), COHb (Fixed Level 6 - Class CS) +COHb

99*        Smoke/Heat/CO Combine, Smoke, CO/Heat Combine, Heat (FT), Heat (RoR), COHb

9C        COHb

9D        CO

FT         = Fixed Temperature

RoR        = Rate of Rise

COHb         = Carboxyhemoglobin

* Reduced false alarm function

117p/02

 

Bases:
YBN-R/4IS    Conventional Intrinsically Safe Mounting base
YCA-RL/3H2M    Addressable base
YBN-R/6SK    Schottky diode base
YBN-R/6    Standard base
YBN-R/3     Standard Analogue Mounting Base
YBN-R/3(WHT)    Standard Analogue Mounting Base
YBN-R/3(SCI)    Short circuit isolator base
YBN-R/3(WHT)-SCI    Short circuit isolator base
YBO-RSCI/NS     Negative Switching Short circuit isolating base
YBF-RL/4H3H    2 wire common mounting base
YBF-RL/4H5H    2 wire common mounting base
YBN-R/6M    Standard Base
YBO-BS          Base sounder
YBO-BS(WHT)    Base sounder
YBO-R/6PA        Protector alarms base
YBO-R/6R          Relay base
YBO-R/6RS        Relay latching base with Schottky diode
YBO-R/6RN        Relay base non-latching
YBN-R/3(SCI)     Short circuit Isolating base
  YBO-BSB2/WL    Base Sounder Beacon (White LED)
YBO-BSB2(WHT)/WL        Base Sounder Beacon (White LED)
YBO-BSB2/RL    Base Sounder Beacon (Red LED)
YBO-BSB2(WHT)/RL         Base Sounder Beacon (Red LED)
YBO-BSB2(WHT)/WL-HFP    Base Sounder Beacon (White LED)
YBO-BSB2(WHT)/RL-HFP    Base Sounder Beacon (Red LED)
RSM-WDB                        Wireless Adaptor Base
YBN-R/3(WHT)       Addressable Standard Mounting Base (White Plastic)
YBN-R/R4IS(WHT)    Conventional Intrinsically Safe Mounting Base (White Plastic)
YBN-R/6(WHT)       Conventional Standard Mounting Base (White Plastic)
YBN-R/6M(WHT)                   Conventional Standard Marine Mounting Base (White Plastic)
YBN-R/6SK(WHT)    Conventional Schottky Diode Mounting Base (White Plastic)
YBO-BS(WHT)       Addressable Base Sounder (White Plastic)
YBO-R/6PA(WHT)    Conventional 2 Wire S Mounting Base
YBO-R/6R(WHT)                   Conventional Relay Mounting Base Latching (White Plastic)
YBO-R/6RS(WHT)    Conventional Relay Mounting Base Latching with Schottky Diode (White Plastic)
YBO-R/6RN(WHT)    Conventional Relay Mounting Base Non-Latching with Schottky Diode (White Plastic)
YBN-R/3(WHT)-SCI    Addressable Short Circuit Isolating Mounting Base (White Plastic)
YBO-BSB2(BLK)/RL    Addressable Base Sounder Beacon (Red LED) - Black Plastic
YBO-BSB2(BLK)/WL    Addressable Base Sounder Beacon (White LED) - Black Plastic

 


 

To read the Red Book section introduction click here.

 

< back to results page

< back to search page