Gent By Honeywell (Novar Systems Ltd)

140 Waterside Road
Hamilton Industrial Park
Leicester
LE5 1TN
United Kingdom

Tel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300
Email: gent_enquiry@gent.co.uk • Web: www.gent.co.uk




Certificate No 042an to EN 54-5: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1:2002 + A2: 2006, EN 54-17: 2005, EN 54-18: 2005 and CEA 4021: 2003
Certificate No 042bf to EN54-5: 2000+A1: 2002, EN54-7: 2000+A1: 2002+A2: 2006, EN54-17: 2005, EN54-18: 2005
Certificate No 042bv to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN54-17: 2005, EN54-18: 2005, EN54-23: 2010
Certificate No 042ca to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005,
Certificate No 042bu to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005,
Certificate No 042bz to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005,
Certificate No 042bw to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005, EN54-23: 2010
Certificate No 042ak to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005,


Multi-criteria Detectors

Product Description LPCB
Ref. No.
S4-711-ST-VO

S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with speech and

strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

Notes:

1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:

        State 0 - Medium optical / Class A1 heat

        State 5 - Medium optical / Class B heat

        State 8 - Delayed medium optical / Class A1 heat

2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:

        High - Continuous 933 Hz

        Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

3) Speech function is not approved against Annex C requirements of EN 54-3

042an/01
S4-771

S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector

with sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

Notes:

1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:

        State 0 - Medium optical / Class A1 heat

        State 5 - Medium optical / Class B heat

        State 8 - Delayed medium optical / Class A1 heat

2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:

        High - Continuous 933 Hz

        Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

042an/02
S4-911-ST-VO

S-Quad analogue addressable optical smoke, heat and carbon monoxide multisensor detector

with speech and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

Notes:

1) Meets the requirements of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:

        State 0 - Medium optical / Class A1 heat

2) Meets the requirements of EN 54: Part 5 at the following settings:

        State 9 - Class A1 heat

3) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:

        High - Continuous 933 Hz

        Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

4) Carbon monoxide detection, speech and strobe not included within the scope of this approval

5) Speech function is not approved against Annex C requirements of EN 54-3

042an/03
S4-770-ST

S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector with sounder and strobe

(S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

Notes:

1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the
     following settings:

     State 0 - Medium optical / Class A1 heat

2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:

     High - Continuous 933 Hz

     Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

3) Strobe not included in scope of approval.

042an/06
S4-710

S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit and S4-700-34K)

Note:

1)        Meets the requirement of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

        State 0 - Medium optical / Class A1 heat

        State 2 - Low sensitivity / Class A1 heat*

        State 3 - High sensitivity / Class A1 heat

        State 4 - Medium optical (no spoke) / Class A1 heat

        State 5 - Medium optical / Class B heat

        State 6 - Low sensitivity / Class BS heat*

        State 7 - Medium optical / Class A2S heat

        State 8 - Delayed medium optical / Class A1 heat

        State 11 - Low sensitivity / Class B heat*

        State 12 - Off / Class A1 heat*

*Does not meet the requirement of EN 54-7

042bf/01
S4-711

S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush fixing kit and S4-700-34K)

Notes:

1) Meets the requirement of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

        State 0 - Medium optical / Class A1 heat

        State 2 - Low sensitivity / Class A1 heat*

        State 3 - High sensitivity / Class A1 heat

        State 4 - Medium optical (no spoke) / Class A1 heat

        State 5 - Medium optical / Class B heat

        State 6 - Low sensitivity / Class BS heat*

        State 7 - Medium optical / Class A2S heat

        State 8 - Delayed medium optical / Class A1 heat

        State 11 - Low sensitivity / Class B heat*

        State 12 - Off / Class A1 heat*

*Does not meet the requirement of EN 54-7

042bf/02
S4-711-VO

S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with speech (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

Note:

1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:

        State 0 - Medium optical / Class A1 heat

        State 5 - Medium optical / Class B heat

        State 8 - Delayed medium optical / Class A1 heat

2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:

        High - Continuous 933 Hz

        Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

3) Speech function is not approved against Annex C requirements of EN 54-3

042an/05
S4-770

S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector with sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

Note:

1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:

        State 0 - Medium optical / Class A1 heat

2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:

        High - Continuous 933 Hz

        Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

042an/04
S4-720-V-VAD-HPR

Analogue Addressable Class P Heat Sensor with Voice, Sounder and Red Visual Alarm (S4-701 Base and S4-700-34K)

Notes:

1.   Meets the requirements of EN 54-3 at the following sounder tone settings:

      High - Continuous 933 Hz

      Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.   Meets the requirements of EN 54-5 at the following settings:

       State 0 - Class A1 heat

       State 5 - Class B heat

3.   The ceiling mounted Visual Alarm Device (VAD) meets the requirements of      

       EN 54-23 for the following:

       - Category (light pattern details)

      @ High power setting - (Category C: C-3-14 and Category O: O-4.5-14)

      @ Medium power setting - (Category C: C-3-13 and Category O: O-4-13)

      @ Low power setting - (Category C: C-3-10 and Category O: None)

      - Synchronization

      - Flash rate 2 seconds (0.5Hz)

4.   Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

042bv/01
S4-720-V-VAD-HPW

Analogue Addressable Class P Heat Sensor with Voice, Sounder and White Visual Alarm (S4-701 base and S4-700-34K)

Notes:
1.   Meets the requirements of EN 54-3 at the following sounder tone    settings:

      High - Continuous 933 Hz

      Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.   Meets the requirements of EN 54-5 at the following settings:

      State 0 - Class A1 heat

      State 5 - Class B heat

3.   The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN      

      54-23 for the following:

      - Category (light pattern details)

      @ High power setting - (Category C: C-6-16 and Category O: None)

      @ Medium power setting - (Category C: C-3-14 and Category O: O-5-14)

      @ Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8

      - Synchronization

      - Flash rate 2 seconds (0.5Hz)

4.   Must be used with the S4-701 base and IP seal plate in order to achieve IP21CNotes:
                                      

042bv/02
S4-711-V

Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with Speech (S4-700 standard base with or without S4-FLUSH Semi-flush mounting kit and S4-700-34K)

Notes:
1.   Meets the requirements of EN 54-3 at the following sounder tone settings:

      High - Continuous 933 Hz

      Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.   Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

        State 0 - Medium optical / Class A1 heat

        State 2 - Low sensitivity / Class A1 heat*

        State 3 - High sensitivity / Class A1 heat

        State 4 - Medium optical (no spoke) / Class A1 heat

        State 5 - Medium optical / Class B heat

        State 6 - Low sensitivity / Class BS heat*

        State 7 - Medium optical / Class A2S heat

        State 8 - Delayed medium optical / Class A1 heat

        State 11 - Low sensitivity / Class B heat*

        State 12 - Off / Class A1 heat*

*Does not meet the requirement of EN 54-7

042ca/01
S4-771-S

Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with Sounder (S4-700 standard base with or without S4-FLUSH semi-flush mounting kit and S4-700-34K)

Notes:
1.   Meets the requirements of EN 54-3 at the following sounder tone settings:

      High - Continuous 933 Hz

      Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.   Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

        State 0 - Medium optical / Class A1 heat

        State 2 - Low sensitivity / Class A1 heat*

        State 3 - High sensitivity / Class A1 heat

        State 4 - Medium optical (no spoke) / Class A1 heat

        State 5 - Medium optical / Class B heat

        State 6 - Low sensitivity / Class BS heat*

        State 7 - Medium optical / Class A2S heat

        State 8 - Delayed medium optical / Class A1 heat

        State 11 - Low sensitivity / Class B heat*

        State 12 - Off / Class A1 heat*

*Does not meet the requirement of EN 54-7

042ca/02
S4-770-S

Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Sounder (S4-700 standard base with or without S4-FLUSH semi-flush mounting kit and S4-700-34K)

Notes:
1.   Meets the requirements of EN 54-3 at the following sounder tone settings:

      High - Continuous 933 Hz

      Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.   Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

        State 0 - Medium optical / Class A1 heat

        State 2 - Low sensitivity / Class A1 heat*

        State 3 - High sensitivity / Class A1 heat

        State 4 - Medium optical (no spoke) / Class A1 heat

        State 5 - Medium optical / Class B heat

        State 6 - Low sensitivity / Class BS heat*

        State 7 - Medium optical / Class A2S heat

        State 8 - Delayed medium optical / Class A1 heat

        State 11 - Low sensitivity / Class B heat*

        State 12 - Off / Class A1 heat*

*Does not meet the requirement of EN 54-7

042ca/03
S4-911-V-VAD-HPR

Analogue Addressable Dual Optical Smoke and Class P Heat and CO Multi-Sensor Detector with Speech, Sounder and Red Visual Alarm (S4-701 Base and S4-700-34K)

Notes:

1.   Meets the requirements of EN 54-3 at the following sounder tone settings:

      High- Continuous 933 Hz

      Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.   Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

State 0 - Medium optical / Class A1 heat

State 1 - High sensitivity / Class A1 heat

State 2 - Low sensitivity / Class A1 heat

State 4 - Medium optical (no spike) / Class A1 heat

State 6 - Low sensitivity / Class BS heat*

State 7 - Medium optical / Class A2S heat

State 9 - Class A1 heat*

State 11 - Low sensitivity / Class B heat

State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

3.   The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following:

      - Category (light pattern details)

      - High power setting - (Category C: C-3-14 and Category O: O-4.5-14)

- Medium power setting - (Category C: C-3-13 and Category O: O-4-13)

- Low power setting - (Category C: C-3-10)

- Synchronization

- Flash rate 2 seconds (0.5Hz)

4.    Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

042bu/04
S4-911-V-VAD-HPW

Analogue Addressable Dual Optical Smoke and Class P Heat and CO Multi-Sensor Detector with Speech, Sounder and White Visual Alarm (S4-701 Base and S4-700-34K)

Notes:

1.   Meets the requirements of EN 54-3 at the following sounder tone settings:

      High- Continuous 933 Hz

      Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.   Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

State 0 - Medium optical / Class A1 heat

State 1 - High sensitivity / Class A1 heat

State 2 - Low sensitivity / Class A1 heat

State 4 - Medium optical (no spike) / Class A1 heat

State 6 - Low sensitivity / Class BS heat*

State 7 - Medium optical / Class A2S heat

State 9 - Class A1 heat*

State 11 - Low sensitivity / Class B heat

State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

3.   The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following:

     - Category (light pattern details)

     - High power setting - (Category C: C-6-16 and Category O: None)

     - Medium power setting - (Category C: C-3-14 and Category O: O-5-14)

     - Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8

     - Synchronization

     - Flash rate 2 seconds (0.5Hz)

4.   Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

042bu/05
S4-711-V-VAD-HPR

Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Speech, Sounder and Red Visual Alarm (S4-701 Base and S4-700-34K)

Notes:

1.   Meets the requirements of EN 54-3 at the following sounder tone settings:

      High- Continuous 933 Hz

      Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.   Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

State 0 - Medium optical / Class A1 heat

State 2 - Low sensitivity / Class A1 heat*

State 3 - High sensitivity / Class A1 heat

State 4 - Medium optical (no spike) / Class A1 heat

State 5 - Medium optical / Class B heat

State 6 - Low sensitivity / Class BS heat*

State 7 - Medium optical / Class A2S heat

State 8 - Delayed medium optical / Class A1 heat

State 11 - Low sensitivity / Class B heat*

State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

3.   The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following:

      - Category (light pattern details)

      - High power setting - (Category C: C-3-14 and Category O: O-4.5-14)

      - Medium power setting - (Category C: C-3-13 and Category O: O-4-13)

      - Low power setting - (Category C: C-3-10 and Category O: None)

      - Synchronization

      - Flash rate 2 seconds (0.5Hz)

4.   Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

042bu/06
S4-711-V-VAD-LPW

Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with Speech, Sounder and White Visual Alarm (S4-701 Base and S4-700-34K)

Notes:

1.   Meets the requirements of EN 54-3 at the following sounder tone settings:

      High- Continuous 933 Hz

      Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.   Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

State 0 - Medium optical / Class A1 heat

State 1 - High sensitivity / Class A1 heat

State 2 - Low sensitivity / Class A1 heat*

State 3 - High sensitivity / Class A1 heat

State 4 - Medium optical (no spike) / Class A1 heat

State 5 - Medium optical / Class B heat

State 6 - Low sensitivity / Class BS heat*

State 7 - Medium optical / Class A2S heat

State 8 - Delayed medium optical / Class A1 heat

State 11 - Low sensitivity / Class B heat*

State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

3.   The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following:

      - Category (light pattern details)

      - Low power setting - (Category C: C-3-10 and Category O: None)

      - Synchronization

      - Flash rate 2 seconds (0.5Hz)

4.   Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

042bu/07
S4-711-V-VAD-HPW

Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Speech, Sounder and White Visual Alarm (S4-701 Base and S4-700-34K)

Notes:

1.   Meets the requirements of EN 54-3 at the following sounder tone settings:

      High- Continuous 933 Hz

      Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.   Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

-        State 0 - Medium optical / Class A1 heat

-        State 2 - Low sensitivity / Class A1 heat*

-        State 3 - High sensitivity / Class A1 heat

-        State 4 - Medium optical (no spike) / Class A1 heat

-        State 5 - Medium optical / Class B heat

-        State 6 - Low sensitivity / Class BS heat*

-        State 7 - Medium optical / Class A2S heat

-        State 8 - Delayed medium optical / Class A1 heat

-        State 11 - Low sensitivity / Class B heat*

-        State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

3.   The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following:

      - Category (light pattern details)

      - High power setting - (Category C: C-6-16 and Category O: None)

      - Medium power setting - (Category C: C-3-14 and Category O: O-5-14)

      - Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8

      - Synchronization

      - Flash rate 2 seconds (0.5Hz)

4.   Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

042bu/08
S4-901

Analogue Addressable Dual Optical Smoke and Class P Heat and CO Multi-Sensor Detector (S4-700 Standard Base and S4-700-34K)

Notes:

1.   Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

-        State 0 - Normal sensitivity / Class A1 heat

-        State 1 - High sensitivity / Class A1 heat

-        State 2 - Medium sensitivity / Class A1 heat

-        State 4 - Normal sensitivity (no spike) / Class A1 heat

-        State 6 - Low sensitivity / Class A1 heat*

-        State 7 - Normal sensitivity / Class A2S heat

-        State 9 - Class A1 heat*

-        State 11 - Normal sensitivity (no spike) / Class B heat

-        State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

2.        Carbon Monoxide Detection is not included in the scope of this approval.

042bz/01
S4-711-VAD-HPR

Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with Red Visual Alarm (S4-701 base and S4-700-34K)

Notes:
1.   Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

-        State 0 - Medium optical / Class A1 heat

-        State 2 - Low sensitivity / Class A1 heat*

-        State 3 - High sensitivity / Class A1 heat

-        State 4 - Medium optical (no spike) / Class A1 heat

-        State 5 - Medium optical / Class B heat

-        State 6 - Low sensitivity / Class BS heat*

-        State 7 - Medium optical / Class A2S heat

-        State 8 - Delayed medium optical / Class A1 heat

-        State 11 - Low sensitivity / Class B heat*

-        State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

2.   The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following category (light pattern details):

      - High power setting - (Category C: C-3-14 and Category O: O-4.5-14)

      - Medium power setting - (Category C: C-3-13 and Category O: O-4-13)

      - Low power setting - (Category C: C-3-10 and Category O: None)

      - Synchronization

      - Flash rate 2 seconds (0.5Hz)

3.   Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

042bw/01
S4-711-VAD-LPW

Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with White Visual Alarm (S4-701 base)

Notes:

1.   Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

-        State 0 - Medium optical / Class A1 heat

-        State 2 - Low sensitivity / Class A1 heat*

-        State 3 - High sensitivity / Class A1 heat

-        State 4 - Medium optical (no spike) / Class A1 heat

-        State 5 - Medium optical / Class B heat

-        State 6 - Low sensitivity / Class BS heat*

-        State 7 - Medium optical / Class A2S heat

-        State 8 - Delayed medium optical / Class A1 heat

-        State 11 - Low sensitivity / Class B heat*

-        State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

    

2.   The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following category (light     pattern details):

      - Low power setting - (Category C: C-3-10 and Category O: None)

      - Synchronization

      - Flash rate 2 seconds (0.5Hz)

3.   Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

042bw/02
S4-711-VAD-HPW

Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with White Visual Alarm (S4-701 base and S4-700-34K)

Notes:
1.   Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

-        State 0 - Medium optical / Class A1 heat

-        State 2 - Low sensitivity / Class A1 heat*

-        State 3 - High sensitivity / Class A1 heat

-        State 4 - Medium optical (no spike) / Class A1 heat

-        State 5 - Medium optical / Class B heat

-        State 6 - Low sensitivity / Class BS heat*

-        State 7 - Medium optical / Class A2S heat

-        State 8 - Delayed medium optical / Class A1 heat

-        State 11 - Low sensitivity / Class B heat*

-        State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

2.   The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following category (light pattern details):

      - High power setting - (Category C: C-6-16 and Category O: None)

      - Medium power setting - (Category C: C-3-14 and Category O: O-5-14)

      - Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8)

      - Synchronization

      - Flash rate 2 seconds (0.5Hz)

3.   Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

042bw/03
S4-780-S

Analogue Addressable Class P Heat Sensor with Sounder with Short Circuit Isolator (S4-700 Standard Base and S4-700-34K)

Notes:
1.   Meets the requirements of EN 54-3 at the following tone settings:

      High - Continuous 933 Hz

      Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.   Meets the requirements of EN 54-5 at the following settings:

-        State 0 - Class A1 heat

-        State 5 - Class B heat

-        State 6 - Class BS heat

-        State 7 - Class A2S heat

-        State 13 - Class A2 heat

042ak/04
S4-711-V-VAD-LPR

Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Speech, Sounder and Red Visual Alarm (S4-701 Base and S4-700-34K)

Notes:

1. Meets the requirements of EN 54-3 at the following sounder tone settings:

    - High- Continuous 933 Hz

    - Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

-        State 0 - Medium optical / Class A1 heat

-        State 2 - Low sensitivity / Class A1 heat*

-        State 3 - High sensitivity / Class A1 heat

-        State 4 - Medium optical (no spike) / Class A1 heat

-        State 5 - Medium optical / Class B heat

-        State 6 - Low sensitivity / Class BS heat*

-        State 7 - Medium optical / Class A2S heat

-        State 8 - Delayed medium optical / Class A1 heat

-        State 11 - Low sensitivity / Class B heat*

-        State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN      

    54-23 for the following category (light pattern details):

    - Low power setting - (Category C: C-3-10)

    - Synchronization

    - Flash rate 2 seconds (0.5Hz)

4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

042bu/09
S4BK-711-V

Analogue Addressable Dual Optical Smoke and Class P Heat Multi-sensor with Speech Sounder (Black Body Variant) (S4BK-700 Base with or without S4-FLUSH semi-flush mounting kit)

Notes:

1. Meets the requirements of EN 54-3 at the following sounder tone settings:

  • High - Continuous 933 Hz
  • Alternate - High 933 Hz for 0.25 secs/ Low 700 Hz for 0.25 secs

2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

        State 0 - Medium optical / Class A1 heat

        State 2 - Low sensitivity / Class A1 heat*

        State 3 - High sensitivity / Class A1 heat

        State 4 - Medium optical (no spoke) / Class A1 heat

        State 5 - Medium optical / Class B heat

        State 6 - Low sensitivity / Class BS heat*

        State 7 - Medium optical / Class A2S heat

        State 8 - Delayed medium optical / Class A1 heat

        State 11 - Low sensitivity / Class B heat*

        State 12 - Off / Class A1 heat*

*Does not meet the requirement of EN 54-7

042ca/04
S4BK-711

S-Quad Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor (Black Body Variant) (S4BK-700 base with or without S4-FLUSH semi-flush fixing kit)

Note:

1.Meets the requirement of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

        State 0 - Medium optical / Class A1 heat

        State 2 - Low sensitivity / Class A1 heat*

        State 3 - High sensitivity / Class A1 heat

        State 4 - Medium optical (no spoke) / Class A1 heat

        State 5 - Medium optical / Class B heat

        State 6 - Low sensitivity / Class BS heat*

        State 7 - Medium optical / Class A2S heat

        State 8 - Delayed medium optical / Class A1 heat

        State 11 - Low sensitivity / Class B heat*

        State 12 - Off / Class A1 heat*

*Does not meet the requirement of EN 54-7

042bf/03
S4BK-711-V-VAD-HPR

S-Quad Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor with Speech, Sounder and Red Visual Alarm (Black Body Variant) (S4BK-700 Base and S4BK-705 Base)

Notes:

1. Meets the requirements of EN 54-3 at the following sounder tone settings:

    - High- Continuous 933 Hz

    - Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

-        State 0 - Medium optical / Class A1 heat

-        State 2 - Low sensitivity / Class A1 heat*

-        State 3 - High sensitivity / Class A1 heat

-        State 4 - Medium optical (no spike) / Class A1 heat

-        State 5 - Medium optical / Class B heat

-        State 6 - Low sensitivity / Class BS heat*

-        State 7 - Medium optical / Class A2S heat

-        State 8 - Delayed medium optical / Class A1 heat

-        State 11 - Low sensitivity / Class B heat*

-        State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN      

    54-23 for the following category (light pattern details):

    - High power setting - (Category C: C-3-14 and Category O: O-4.5-14)

    - Medium power setting - (Category C: C-3-13 and Category O: O-4-13)

    - Low power setting - (Category C: C-3-10)

    - Synchronization

    - Flash rate 2 seconds (0.5Hz)

4.  Must be used with the S4BK-700 base and S4BK-705 IP Plate to achieve IP21C

042bu/10

 

Bases:
S4-700 standard base
S4-701 S Quad plate and base
S4-FLUSH semi-flush fixing kit
S4BK-700 standard base (black)
S4BK-705 Black IP21 base covers (pack 5)
S4-700-34K Fusion Adaptor base

 


 

To read the Red Book section introduction click here.

 