Search by Certificate Number

Portakabin Ltd

New lane
Huntington
York
YO32 9PT
United Kingdom

Tel: 01904 611655 • Fax: 01904 611644
Email: sales@portakabin.co.uk • Web: www.portakabin.co.uk


Certificate No 592a(2) to LPS1181 Part 3


Product

Specification

Sandwich panel

thickness only

Fire Resistance (min)

Integrity

Fire Resistance (min)

Insulation

Grade

Core

Material

LPCB
Ref. No.
ULTIMA Building System Building Module (wall)

76mm & 89mm thick

60

15

A

PUR

592a/03
ULTIMA Building System Building Module (ceiling)

47mm thick

60

60

A

PUR

592a/04
ULTIMA Building System Building Module (roof)

110mm thick

-

-

B

PUR

592a/05

 

Notes:
1.     LPCB Ref. No. 592a/03, 592a/04 & 592a/05 Test specimen conformed to LPS1181 size requirements, except width was only 3.6m, the maximum width possible for the module.
2.    LPCB Ref. No. 592a/03 Wall panels laid with long joints in the vertical orientation.
3.    LPCB Ref. No. 592a/04 The test specimen for the ceiling fire resistance test was a combined ceiling and floor construction
4.     LPCB Ref. No. 592a/03 Wall inner surface lining 1x layer 12.5mm thick Gyproc Fireline Duplex, Lafarge GTEC Fire V or Knauf Fireshield Plasterboard with Renolit Minster PVC innerface lining.
5.     LPCB Ref. No. 592a/04 & 592a/05 Inner surface: interior polyester steel.
6.     LPCB Ref. No. 592a/03, 592a/04 & 592a/05 No assessment has been made of the structural performance of the module, or of the inclusion of windows and doors. Therefore there has been no evaluation of the performance should the fire break through a window or door.
7.    LPCB Ref. No. 592a/03, 592a/04 & 592a/05 Test Specimen short wall was 89mm thick and the long walls were 76mm thick.
  

 


 