Search by Certificate Number

Eurobond Laminates Limited

Wentloog Corporate Park
Wentloog
Cardiff
CF3 2ER
United Kingdom

Tel: +44 (0)2920 776677 • Fax: +44 (0)2920 369161
Email: david.bampton@eurobond.co.uk • Web: www.eurobond.co.uk


Certificate No 545c to LPS1181: Part 2: Issue 2


Product

Specification

Thickness

(mm)

Maximum

Unsupported

Panel Length

(m)

Fire

Resistance

(min)

Integrity

Fire

Resistance

(min)

Insulation

Grade

Core

Material

LPCB
Ref. No.
Firemaster Wall Lite

75

3.00

30

30

INT-2

Mineral fibre

545c/01
Firemaster Wall Lite

75

3.00

60

30

INT-2

Mineral fibre

545c/01
Firemaster Wall Lite

100

5.50

30

30

INT-2

Mineral fibre

545c/01
Firemaster Wall Lite

100

4.50

60

60

INT-1

Mineral fibre

545c/01
Firemaster Wall Lite

100

4.00

90

60

INT-1

Mineral fibre

545c/01
Firemaster Wall Lite

125

5.50

30

30

INT-2

Mineral fibre

545c/01
Firemaster Wall Lite

125

4.50

60

60

INT-1

Mineral fibre

545c/01
Firemaster Wall Lite

125

4.00

90

60

INT-1

Mineral fibre

545c/01
Firemaster Wall Lite

150

5.50

60

60

INT-1

Mineral fibre

545c/01
Firemaster Wall Lite

150

5.00

90

90

INT-1

Mineral fibre

545c/01
Firemaster Wall Lite

150

5.00

120

90

INT-1

Mineral fibre

545c/01
Firemaster Wall Lite

175

5.00

120

90

INT-1

Mineral fibre

545c/01
Firemaster Wall Lite

175

5.00

90

90

INT-1

Mineral fibre

545c/01
Firemaster Wall Lite

175

5.50

60

60

INT-1

Mineral fibre

545c/01
Firemaster Wall Lite

200

5.50

60

60

INT-1

Mineral fibre

545c/01
Firemaster Wall Lite

200

5.00

90

90

INT-1

Mineral fibre

545c/01
Firemaster Wall Lite

200

5.00

120

90

INT-1

Mineral fibre

545c/01
Firemaster Wall Extra

75

3.00

30

30

INT-2

Mineral fibre

545c/02
Firemaster Wall Extra

75

3.00

60

60

INT-1

Mineral fibre

545c/02
Firemaster Wall Extra

100

6.00

60

60

INT-1

Mineral fibre

545c/02
Firemaster Wall Extra

100

5.50

90

90

INT-1

Mineral fibre

545c/02
Firemaster Wall Extra

100

5.50

120

120(3)

INT-1

Mineral fibre

545c/02
Firemaster Wall Extra

125

7.50

30

30

INT-2

Mineral fibre

545c/02
Firemaster Wall Extra

125

6.00

60

60

INT-1

Mineral fibre

545c/02
Firemaster Wall Extra

125

5.50

90

90

INT-1

Mineral fibre

545c/02
Firemaster Wall Extra

125

5.50

120

120

INT-1

Mineral fibre

545c/02
Firemaster Wall Extra

150

7.50

60

60

INT-1

Mineral fibre

545c/02
Firemaster Wall Extra

150

7.50

90

90

INT-1

Mineral fibre

545c/02
Firemaster Wall Extra

150

7.50

120

120

INT-1

Mineral fibre

545c/02
Firemaster Wall Extra

175

7.50

60

60

INT-1

Mineral fibre

545c/02
Firemaster Wall Extra

175

7.50

90

90

INT-1

Mineral fibre

545c/02
Firemaster Wall Extra

175

7.50

120

120

INT-1

Mineral fibre

545c/02
Firemaster Ceiling Panel

75

6.00

-

-

INT-3

Mineral fibre

545c/03
Firemaster Ceiling Panel

100

4.20

60

60

INT-1

Mineral fibre

545c/03
Firemaster Ceiling Panel

100

6.00

-

-

INT-3

Mineral fibre

545c/03
Firemaster Ceiling Panel

125

4.20

60

60

INT-1

Mineral fibre

545c/03
Firemaster Ceiling Panel

125

6.00

-

-

INT-3

Mineral fibre

545c/03
Firemaster Ceiling Panel

150

4.20

60

60

INT-1

Mineral fibre

545c/03
Firemaster Ceiling Panel

150

6.00

-

-

INT-3

Mineral fibre

545c/03
Firemaster Wall Ultima

150

7.50

240

240

INT-1

Mineral fibre

545c/05
Firemaster Wall Ultima

175

7.50

240

240

INT-1

Mineral fibre

545c/05
Firemaster Wall Ultima

200

7.50

240

240

INT-1

Mineral fibre

545c/05

 

Notes:
1.    Grade INT-1 approved products have equal performance at Grade INT-2 and INT-3
2.    Grade INT-2 approved products have equal performance at Grade INT-3
3.    LPCB Ref No. 545c/02 - Where Eurobond 120 rock fibre insulation core is used in the 100mm thick panel the fire resistance insulation performance is limited to 90 minutes for maximum unsupported panel lengths of 5.5m
4.    LPCB Ref No. 545c/05 - 150mm and 175mm Firemaster Wall Ultima panel joints are to be stitched on both internal and external faces using 4.7mm diameter x 20mm long self-tapping screws at 300mm centres, the 200mm panel does not require stitching

 


 

To read the Red Book section introduction click here.

 

< back to results page

< back to search page