Certificate No 460a(1) to LPS 1181 Part 1: Issue 1
| Product | Specification System Thickness (mm) | Fire Resistance (min) Integrity | Fire Resistance (min) Insulation | Grade | Core Material | LPCB Ref. No. |
|---|---|---|---|---|---|---|
| Trimapanel wall panel | 70 and 90 |
- |
- |
EXT-B |
PIR* |
460a/13 |
| Built up wall (System W1) | 80 - 220 |
240 |
15 |
EXT-A15 |
Mineral wool |
460a/14 |
| Built up wall (System W1) | 160 - 220 |
240 |
30 |
EXT-A30 |
Mineral wool |
460a/14 |
| Built up roof (System R1) | 60 - 220 |
- |
- |
EXT-B |
Mineral wool |
460a/15 |
| Built up roof (System R2) | 60 - 220 |
- |
- |
EXT-B |
Mineral wool |
460a/16 |
| Trisomet Roof Tile | 40, 60, 80 and 100 |
- |
- |
EXT-B |
PIR* |
460a/18 |
| Trinsul wall system | 90 |
240 |
60 |
EXT-A60 |
Mineral wool |
460a/19 |
| Trinsul wall and roof system | 90 |
- |
- |
EXT-B |
Mineral wool |
460a/19 |
| Structural Liner Tray | 170 |
120 |
15 |
EXT-A15 |
PIR*/Mineral wool |
460a/20 |
| Structural Liner Tray | 170 |
- |
- |
EXT-B |
PIR*/Mineral wool |
460a/20 |
| Structural Liner Tray | 190 |
- |
- |
EXT-B |
PIR*/Mineral wool |
460a/20 |
| Structural Flat Metal Roof Deck | 50 - 200 |
- |
- |
EXT-B |
Mineral wool |
460a/21 |
| Stratatherm façade | 80 - 150 |
- |
- |
EXT-B |
Mineral wool |
460a/22 |
| Built up acoustic wall and roof systems | 175 |
- |
- |
EXT-B |
Mineral wool |
460a/23 |
| Built up acoustic wall system | 175 |
240 |
15 |
EXT-A15 |
Mineral wool |
460a/23 |
| Hybrid Acoustic roof system | 120 |
- |
- |
PIR*/Mineral wool |
460a/24 | |
| Hybrid Acoustic wall system | 100 |
240 |
15 |
EXT-A15 |
PIR*/Mineral wool |
460a/24 |
| Trisomet 333 (roof and wall panel) | 40, 60, 80 & 100 |
- |
- |
EXT-B |
PIR* free PIR |
460a/26 |
| Trisomet 333 (wall panel) | 60, 80 and 100 |
240 |
25 |
EXT-A15 |
PIR* |
460a/27 |
Notes:
1. Trimapanel wall panels (460a/13) can be laid with the long joint vertical or horizontal.
2. Trinsul wall system (460a/19) outer liner 0.55mm steel stitched at minimum 600mm centres, internal liner 0.4mm steel
3. Structural Liner Tray system (460a/20) requires the liner tray joints to be stitched at minimum 450mm centres
4. Structural Flat Metal roof deck (460a/21) steel profile liner D19 - D35 require no side lap stitching, steel profile liner D46 - D159 require side lap stitching min. 450mm c/c and steel profile liner D210 require side lap stitching min 350mm c/c
5. Trisomet 333 wall panels (460a/26) can be laid with the long joints in the vertical orientation stitched or unstitched or in the horizontal orientation with the overlap joint stitched at maximum 600mm centres.
6. Trisomet 333 roof panels (460a/26) are to be secured to each purlin with 3 fixings, the perimeter of the roof system is to be secured to the frame support through the panel edge at 300mm centres.
7. Trisomet 333 wall panels (460a/27) are to be laid with the long joints vertically only and stitched at maximum 300mm centres with SL2-T-A14-4.8x20 self tapping steel screws or similar.
8. The PIR core materials marked * are both CFC and HCFC Free and are stated to be Low Global Warming Potential (GWP).