Certificate No 460a(1) to LPS 1181 Part 1: Issue 1

Product Specification

System Thickness

(mm)

Fire

Resistance

(min)

Integrity

Fire

Resistance

(min)

Insulation

Grade

Core

Material

LPCB Ref. No.
Trimapanel wall panel

70 and 90

-

-

EXT-B

PIR*

460a/13
Built up wall (System W1)

80 - 220

240

15

EXT-A15

Mineral wool

460a/14
Built up wall (System W1)

160 - 220

240

30

EXT-A30

Mineral wool

460a/14
Built up roof (System R1)

60 - 220

-

-

EXT-B

Mineral wool

460a/15
Built up roof (System R2)

60 - 220

-

-

EXT-B

Mineral wool

460a/16
Trisomet Roof Tile

40, 60, 80 and 100

-

-

EXT-B

PIR*

460a/18
Trinsul wall system

90

240

60

EXT-A60

Mineral wool

460a/19
Trinsul wall and roof system

90

-

-

EXT-B

Mineral wool

460a/19
Structural Liner Tray

170

120

15

EXT-A15

PIR*/Mineral wool

460a/20
Structural Liner Tray

170

-

-

EXT-B

PIR*/Mineral wool

460a/20
Structural Liner Tray

190

-

-

EXT-B

PIR*/Mineral wool

460a/20
Structural Flat Metal Roof Deck

50 - 200

-

-

EXT-B

Mineral wool

460a/21
Stratatherm façade

80 - 150

-

-

EXT-B

Mineral wool

460a/22
Built up acoustic wall and roof systems

175

-

-

EXT-B

Mineral wool

460a/23
Built up acoustic wall system

175

240

15

EXT-A15

Mineral wool

460a/23
Hybrid Acoustic roof system

120

-

-

PIR*/Mineral wool

460a/24
Hybrid Acoustic wall system

100

240

15

EXT-A15

PIR*/Mineral wool

460a/24
Trisomet 333 (roof and wall panel)

40, 60, 80

& 100

-

-

EXT-B

PIR*

free PIR

460a/26
Trisomet 333 (wall panel)

60, 80 and 100

240

25

EXT-A15

PIR*

460a/27

 

    
Notes:
1.    Trimapanel wall panels (460a/13) can be laid with the long joint vertical or horizontal.
2.    Trinsul wall system (460a/19) outer liner 0.55mm steel stitched at minimum 600mm centres, internal liner 0.4mm steel
3.    Structural Liner Tray system (460a/20) requires the liner tray joints to be stitched at minimum 450mm centres
4.    Structural Flat Metal roof deck (460a/21) steel profile liner D19 - D35 require no side lap stitching, steel profile liner D46 - D159 require side lap stitching min. 450mm c/c and steel profile liner D210 require side lap stitching min 350mm c/c
5.    Trisomet 333 wall panels (460a/26) can be laid with the long joints in the vertical orientation stitched or unstitched or in the horizontal orientation with the overlap joint stitched at maximum 600mm centres.  
6.    Trisomet 333 roof panels (460a/26) are to be secured to each purlin with 3 fixings, the perimeter of the roof system is to be secured to the frame support through the panel edge at 300mm centres.
7.    Trisomet 333 wall panels (460a/27) are to be laid with the long joints vertically only and stitched at maximum 300mm centres with SL2-T-A14-4.8x20 self tapping steel screws or similar.
8.    The PIR core materials marked * are both CFC and HCFC Free and are stated to be Low Global Warming Potential (GWP).

 

 

To read the Red Book section introduction click here.

 

< back to results page

< back to search page