Search by Certificate Number

SMS (Novar Systems Ltd)

Hamilton Industrial Park
140 Waterside Road
Leicester
LE5 1TN
United Kingdom

Tel: +44 (0)116 246 2100 • Fax: +44 (0)116 246 2016
Web: www.smsfire.co.uk


Certificate No 042bk to EN 54-3: 2001 + A1: 2002 + A2: 2006
Certificate No 042bj to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Certificate No 567z-(cl-1) to EN 54-3:2001 + A1:2002 + A2:2006 & EN 54-17:2005



Certificate No 567ah-(cl-1) to EN 54-17: 2005 & EN 54-23: 2010
Certificate No 567ag-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006, EN 54-17: 2005 & EN 54-23: 2010




Product Description LPCB
Ref. No.
SEN-S-EP-R

Sentri Type A Red Body Sounder with Short Circuit Isolator (Back Box)

Note:

1.        Meets the requirements of EN 54-3 at the following sounder tone settings:

1.        Intermittent tone 970Hz @ 1Hz

2.        Alternating tone 730/970Hz @ 2Hz

3.        Continuous tone 970Hz

Bases:

Black Box

567z/06
SEN-S-VAD-HPR-R

Sentri Type A Red High Performance VAD Red Body Sounder with Short Circuit Isolator (S3-DB-R and S3-SB-R Bases)

Notes:

1.        Meets the requirements of EN 54-3 at the following sounder tone settings:

1.        Intermittent tone 970Hz @ 1Hz

2.        Alternating tone 730/970Hz @ 2Hz

3.        Continuous tone 970Hz

2.        Meets the requirements of EN 54-23 at the following power settings:

-        Low red output

-        Medium red output

-        High red output

3.      The wall mounted Visual Alarm Device (VAD) meets the requirements of EN      

         54-23 for the following light pattern details:

  -     High Performance setting - (Category W: W-6.7-14)

  -     Medium Performance setting - (Category W: W-6.5-12.5)

  -     Low Performance setting - (Category W: W-5-9.5)

  -     Synchronization

         -     Flash rate 2 seconds (0.5Hz)

567ag/01
SEN-S-VAD-HPW-R

Sentri Type A White High Performance VAD Red Body Sounder with Short Circuit Isolator (S3-DB-R and S3-SB-R Bases)

Notes:

1.        Meets the requirements of EN 54-3 at the following sounder tone settings:

1.        Intermittent tone 970Hz @ 1Hz

2.        Alternating tone 730/970Hz @ 2Hz

3.        Continuous tone 970Hz

2.        Meets the requirements of EN 54-23 at the following power settings:

-        Low white output

-        Medium white output

-        High white output

3.     The wall mounted Visual Alarm Device (VAD) meets the requirements of EN      

        54-23 for the following light pattern details:

-      High Performance setting - (Category W: W-5-12.5)

-      Medium Performance setting - (Category W: W-4.5-11.3)

-      Low Performance setting - (Category W: W-3-8.5)

-      Synchronization

-      Flash rate 2 seconds (0.5Hz)

567ag/04
SEN-S-VAD-LPR-R

Sentri Type A Red Standard Performance VAD Red Body Sounder with Short Circuit Isolator (S3-DB-R and S3-SB-R Bases)

Notes:

1.        Meets the requirements of EN 54-3 at the following sounder tone settings:

1.        Intermittent tone 970Hz @ 1Hz

2.        Alternating tone 730/970Hz @ 2Hz

3.        Continuous tone 970Hz

2.      The wall mounted Visual Alarm Device (VAD) meets the requirements of EN      

         54-23 for the following light pattern details:

-        Low Performance setting - (Category W: W-3-8.5)

-        Synchronization

-        Flash rate 2 seconds (0.5Hz)

567ag/19
SEN-S-VAD-LPW-R

Sentri Type A White Standard Performance VAD Red Body Sounder with Short Circuit Isolator (S3-DB-R and S3-SB-R Bases)

Notes:

1.        Meets the requirements of EN 54-3 at the following sounder tone settings:

1.        Intermittent tone 970Hz @ 1Hz

2.        Alternating tone 730/970Hz @ 2Hz

3.        Continuous tone 970Hz

2.     The wall mounted Visual Alarm Device (VAD) meets the requirements of EN      

        54-23 for the following light pattern details:

-        Low Performance setting - (Category W: W-3-8.5)

-        Synchronization

-        Flash rate 2 seconds (0.5Hz)

567ag/20
SEN-S-R

Sentri Type A Red Body Sounder with Short Circuit Isolator (S3-DB-R and S3-SB-R Bases)

Note:

1.        Meets the requirements of EN 54-3 at the following sounder tone settings:

1.        Intermittent tone 970Hz @ 1Hz

2.        Alternating tone 730/970Hz @ 2Hz

3.  Continuous tone 970Hz

567z/01
SEN-VAD-HPR-R

Sentri Type A Red High Performance VAD Red Body with Short Circuit Isolator (S3-DB-R and S3-SB-R Bases)

Notes:

  1. Meets the requirements of EN 54-23 at the following power settings:
  2. Low red output
  3. Medium red output
  4. High red output
  5. 2.     The wall mounted Visual Alarm Device (VAD) meets the requirements of EN      

            54-23 for the following light pattern details:

      -     High Performance setting - (Category W: W-6.7-14)

      -     Medium Performance setting - (Category W: W-6.5-12.5)

      -     Low Performance setting - (Category W: W-5-9.5)

      -     Synchronization

      -     Flash rate 2 seconds (0.5Hz)

567ah/01
SEN-VAD-HPW-R

Sentri Type A White High Performance VAD Red Body with Short Circuit Isolator (S3-DB-R and S3-SB-R Bases)

Notes:

  1. Meets the requirements of EN 54-23 at the following power settings:
  2. Low white output
  3. Medium white output
  4. High white output
  5. 2.      The wall mounted Visual Alarm Device (VAD) meets the requirements of EN      

             54-23 for the following light pattern details:

      -      High Performance setting - (Category W: W-5-12.5)

      -      Medium Performance setting - (Category W: W-4.5-11.3)

      -      Low Performance setting - (Category W: W-3-8.5)

      -      Synchronization

      -      Flash rate 2 seconds (0.5Hz)

567ah/02
SEN-S-VAD-HPR-EP-R

Sentri Type A Red High Performance VAD Red Body Sounder with Short Circuit Isolator (Back Box)

Notes:

1.        Meets the requirements of EN 54-3 at the following sounder tone settings:

1.        Intermittent tone 970Hz @ 1Hz

2.        Alternating tone 730/970Hz @ 2Hz

3.        Continuous tone 970Hz

2.        Meets the requirements of EN 54-23 at the following power settings:

-        Low red output

-        Medium red output

-        High red output

3.      The wall mounted Visual Alarm Device (VAD) meets the requirements of EN      

         54-23 for the following light pattern details:

  -     High Performance setting - (Category W: W-6.7-14)

  -     Medium Performance setting - (Category W: W-6.5-12.5)

  -     Low Performance setting - (Category W: W-5-9.5)

  -     Synchronization

  -          Flash rate 2 seconds (0.5Hz)

567ag/02
SEN-S-VAD-HPW-EP-R

Sentri Type A White High Performance VAD Red Body Sounder with Short Circuit Isolator (Back Box)

Notes:

1.        Meets the requirements of EN 54-3 at the following sounder tone settings:

1.        Intermittent tone 970Hz @ 1Hz

2.        Alternating tone 730/970Hz @ 2Hz

3.        Continuous tone 970Hz

2.        Meets the requirements of EN 54-23 at the following power settings:

-        Low white output

-        Medium white output

-        High white output

3.     The wall mounted Visual Alarm Device (VAD) meets the requirements of EN      

        54-23 for the following light pattern details:

-      High Performance setting - (Category W: W-5-12.5)

-      Medium Performance setting - (Category W: W-4.5-11.3)

-      Low Performance setting - (Category W: W-3-8.5)

-      Synchronization

-      Flash rate 2 seconds (0.5Hz)

567ag/18

 

S3-DB-R    Deep Base - Red
S3-SB-R    Shallow Base - Red

 


 

To read the Red Book section introduction click here.

 

< back to results page

< back to search page