SMS (Novar Systems Ltd)

Hamilton Industrial Park
140 Waterside Road
Leicester
LE5 1TN
United Kingdom

Tel: +44 (0)116 246 2100 • Fax: +44 (0)116 246 2016
Web: www.smsfire.co.uk



Certificate No 042an to EN 54-7: 2000 + A1: 2002, EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002, EN 54-17: 2005, EN 54-18: 2005 and CEA 4021: 2003,
Certificate No 042bf to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005
Certificate No 567ac-(cl-1) to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN54-17: 2005, EN54-18: 2005, EN54-23: 2010
Certificate No 567j-(cl-1) to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1 :2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005,
Certificate No 567ab-(cl-1) to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005, EN 54-23: 2010,
Certificate No 567aa-(cl-1) to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005,


Multi Criteria Detectors

Product Description LPCB
Ref. No.
SEN-770

S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector with sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

Notes:

1.  Meets the requirement of EN 54-5 and EN 54-7 at the following settings:

     State 0 - Medium optical / Class A1 heat

2.  Meets the requirements of EN 54-3 at the following sounder tone settings:

     High - Continuous 933 Hz

    Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

042an/04
SEN-770-ST

S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector with sounder and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

Notes:

1. Meets the requirement of EN 54- 5 and EN 54-7 at the following settings:

     State 0 -  Medium optical / Class A1 heat

2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings:

     High - Continuous 933 Hz

     Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

3. Strobe not included in scope of approval.

042an/06
SEN-710

S-Quad Analogue Addressable Optical Smoke and Class A1 Heat Multi-Sensor Detector

(S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

Note:

1. Meets the requirement of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

        State 0 - Medium optical / Class A1 heat

        State 2 - Low sensitivity / Class A1 heat*

        State 3 - High sensitivity / Class A1 heat

        State 4 - Medium optical (no spoke) / Class A1 heat

        State 5 - Medium optical / Class B heat

        State 6 - Low sensitivity / Class BS heat*

        State 7 - Medium optical / Class A2S heat

        State 8 - Delayed medium optical / Class A1 heat

        State 11 - Low sensitivity / Class B heat*

        State 12 - Off / Class A1 heat*

*Does not meet the requirement of EN 54-7

042bf/01
SEN-780-VAD-HPR

Analogue Addressable Class P Heat Sensor with Red Visual Alarm and Sounder with Short Circuit Isolator (S4-701 Base)

Notes:

1.        Meets the requirements of EN 54-3 at the following sounder tone settings:

-        High - Continuous 933 Hz

-        Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.        Meets the requirements of EN 54-5 at the following settings:

-        State 0 - Class A1 heat

-        State 5 - Class B heat

-        State 6 - Class BS Heat

-        State 7 - Class A2S heat

-        State 13 - Class A2 heat

3.        The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 or the following category (light pattern details):

-        High power setting - (Category C: C-3-14 and Category O: O-4.5-14)

-        Medium power setting - (Category C: C-3-13 and Category O: O-4-13)

-        Low power setting - (Category C: C-3-10 and Category O: None)

-        Synchronization

-        Flash rate 2 seconds (0.5Hz)

Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

567ac/03
SEN-780-VAD-LPW

Analogue Addressable Class P Heat Sensor with White Visual Alarm and Sounder with Short Circuit Isolator (S4-701 Base)

Notes:

1.        Meets the requirements of EN 54-3 at the following sounder tone settings:

-        High - Continuous 933 Hz

-        Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.        Meets the requirements of EN 54-5 at the following settings:

-        State 0 - Class A1 heat

-        State 5 - Class B heat

-        State 6 - Class BS Heat

-        State 7 - Class A2S heat

-        State 13 - Class A2 heat

3.        The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following category (light pattern details):

-        Low power setting - (Category C: C-3-10 and Category O: None)

-        Synchronization

-        Flash rate 2 seconds (0.5Hz)

4.        Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

567ac/04
SEN-780-VAD-HPW

Analogue Addressable Class P Heat Sensor with White Visual Alarm and Sounder with Short Circuit Isolator (S4-701 Base)

Notes:

1.        Meets the requirements of EN 54-3 at the following sounder tone settings:

-        High- Continuous 933 Hz

-        Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.        Meets the requirements of EN 54-5 at the following settings:

-        State 0 - Class A1 heat

-        State 5 - Class B heat

-        State 6 - Class BS Heat

-        State 7 - Class A2S heat

-        State 13 - Class A2 heat

3.        The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 category (light pattern details):

-        High power setting - (Category C: C-6-16 and Category O: None)

-        Medium power setting - (Category C: C-3-14 and Category O: O-5-14)

-        Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8

-        Synchronization

-        Flash rate 2 seconds (0.5Hz)

4.        Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

567ac/05
SEN-770-S

Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Sounder

(S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

Notes:
1.   Meets the requirements of EN 54-3 at the following sounder tone settings:

      High - Continuous 933 Hz

      Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.   Meets the requirements of EN 54-5 and EN 54-7 at the following settings except where otherwise stated:

-        State 0 - Medium optical / Class A1 heat

-        State 2 - Low sensitivity / Class A1 heat*

-        State 3 - High sensitivity / Class A1 heat

-        State 4 - Medium optical (no spike) / Class A1 heat

-        State 5 - Medium optical / Class B heat

-        State 6 - Low sensitivity / Class BS heat*

-        State 7 - Medium optical / Class A2S heat

-        State 8 - Delayed medium optical / Class A1 heat

-        State 11 - Low sensitivity / Class B heat*

-        State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

567j/08
SEN-770-VAD-HPR

Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Sounder and Red Visual Alarm (S4-701 Base)

Notes:

1. Meets the requirements of EN 54-3 at the following sounder tone settings:

    - High- Continuous 933 Hz

    - Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings except    where otherwise stated:

-        State 0 - Medium optical / Class A1 heat

-        State 2 - Low sensitivity / Class A1 heat*

-        State 3 - High sensitivity / Class A1 heat

-        State 4 - Medium optical (no spike) / Class A1 heat

-        State 5 - Medium optical / Class B heat

-        State 6 - Low sensitivity / Class BS heat*

-        State 7 - Medium optical / Class A2S heat

-        State 8 - Delayed medium optical / Class A1 heat

-        State 11 - Low sensitivity / Class B heat*

-        State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN      

    54-23 for the following category (light pattern details):

    - High power setting - (Category C: C-3-14 and Category O: O-4.5-14)

    - Medium power setting - (Category C: C-3-13 and Category O: O-4-13)

    - Low power setting - (Category C: C-3-10)

    - Synchronization

    - Flash rate 2 seconds (0.5Hz)

4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

567ab/01
SEN-770-VAD-HPW

Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Sounder and White Visual Alarm (S4-701 Base)

Notes:

1. Meets the requirements of EN 54-3 at the following sounder tone settings:

    - High- Continuous 933 Hz

    - Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings except    where otherwise stated:

-        State 0 - Medium optical / Class A1 heat

-        State 2 - Low sensitivity / Class A1 heat*

-        State 3 - High sensitivity / Class A1 heat

-        State 4 - Medium optical (no spike) / Class A1 heat

-        State 5 - Medium optical / Class B heat

-        State 6 - Low sensitivity / Class BS heat*

-        State 7 - Medium optical / Class A2S heat

-        State 8 - Delayed medium optical / Class A1 heat

-        State 11 - Low sensitivity / Class B heat*

-        State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN      

    54-23 for the following category (light pattern details):

     - High power setting - (Category C: C-6-16)

     - Medium power setting - (Category C: C-3-14 and Category O: O-5-14)

     - Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8

     - Synchronization

     - Flash rate 2 seconds (0.5Hz)

4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

567ab/02
SEN-770-VAD-LPW

Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Sounder and White Visual Alarm (S4-701 Base)

Notes:

1. Meets the requirements of EN 54-3 at the following sounder tone settings:

    - High- Continuous 933 Hz

    - Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings except    where otherwise stated:

-        State 0 - Medium optical / Class A1 heat

-        State 2 - Low sensitivity / Class A1 heat*

-        State 3 - High sensitivity / Class A1 heat

-        State 4 - Medium optical (no spike) / Class A1 heat

-        State 5 - Medium optical / Class B heat

-        State 6 - Low sensitivity / Class BS heat*

-        State 7 - Medium optical / Class A2S heat

-        State 8 - Delayed medium optical / Class A1 heat

-        State 11 - Low sensitivity / Class B heat*

-        State 12 - Off / Class A1 heat*

*Does not meet the requirements of EN 54-7

3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of

     EN 54-23 for the following category (light pattern details):

     - Low power setting - (Category C: C-3-10)

     - Synchronization

     - Flash rate 2 seconds (0.5Hz)

4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

567ab/03
SEN-780-S

Analogue Addressable Class P Heat Sensor with Sounder with Short Circuit Isolator (S4-700 Standard base)        

Notes:
1.   Meets the requirements of EN 54-3 at the following sounder tone settings:

      High - Continuous 933 Hz

      Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2.   Meets the requirements of EN 54-5 at the following settings:

-        State 0 - Class A1 heat

-        State 5 - Class B heat

-        State 6 - Class BS heat

-        State 7 - Class A2S heat

-        State 13 - Class A2 heat

567aa/01
SEN-770-VAD-LPR

Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Sounder and Red Visual Alarm (S4-701 Base)

Notes:

1. Meets the requirements of EN 54-3 at the following sounder tone settings:

    - High- Continuous 933 Hz

    - Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:

     - State 0 -  Medium Optical / Class A1 Heat

     - State 5 -  Medium Optical / Class B Heat

     - State 8 - Delayed Medium Optical / Class A1 Heat

3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN      

    54-23 for the following category (light pattern details):

    - Low power setting - (Category C: C-3-10)

    - Synchronization

    - Flash rate 2 seconds (0.5Hz)

4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C

567ab/09

 

Bases:
S4-700 standard base
S4-701 S4 Quad Plate and Base
S4-FLUSH Semi-flush fixing kit

 


 

To read the Red Book section introduction click here.

 