Search by Certificate Number

Multron Systems Pte Ltd

217 Kallang Bahru
Multron Building
Singapore
339 347
Singapore

Tel: +65 6743 2555 / 6395 6868 • Fax: +65 6743 2777 / 6395 6869
Email: info@multron.com • Web: www.multron.com


Certificate No 548j-(cl-6) to EN 54-2: 1997 & EN 54-4: 1997
Certificate No 548p-(cl-3) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No 1330h-(cl-3) to EN54-2: 1997 + A1: 2006 & EN54-4: 1997 + A1: 2002 + A2: 2006




Product Description LPCB
Ref. No.
MPC-101

Single zone conventional control and indicating equipment

Certified with the following options with requirements from EN 54 part 2:

7.8        Output to Fire Alarm Devices

10                Test condition

548j/02
MPC-102

Two zone conventional control and indicating equipment

Certified with the following options with requirements from EN 54 part 2:

7.8        Output to Fire Alarm Devices

10                Test condition

548j/03
MPC-104

Four zone conventional control and indicating equipment

Certified with the following options with requirements from EN 54 part 2:

7.8        Output to Fire Alarm Devices

10                Test condition

548j/04
MPC-108

Eight zone conventional control and indicating equipment

Certified with the following options with requirements from EN 54 part 2:

7.8        Output to Fire Alarm Devices

10                Test condition

548j/05
MPC-116

Sixteen zone conventional control and indicating equipment

Certified with the following options with requirements from EN 54 part 2:

7.8        Output to Fire Alarm Devices

10                Test condition

548j/06
IFP2

Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment

Incorporating the following units:

MB-220/ F7.820.826                         Main board

SB-220/ F7.820.827                         Switch board

TB-220/ F7.820.828                               Loop interface board

PS-220/ F7.820.829b                         Power supply unit

ZP-220/ F7.820.312d Zone                 indication and intervention board

Incorporating as optional modular units:

P-9930/ F7.820.913a                         RS-232 board for configuration

P-9901A                                 Printer module kit

LC200/ F7.820.1125                         Loop board (for loop expansion)

Certified with the following options with requirements from EN 54 part 2:

7.8                                         Output to Fire Alarm Devices

7.10.1                                         Output to automatic Fire Protection Equipment Type A

7.11                                         Delays to outputs

8.3                                         Fault signals from points

9.5                                                          Disablement of addressable points

548p/01
IFP8

Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment

Incorporating the following units:

SB-800                Indication board

LCIFP8                Loop board

PB-800                Power board

ZP-800                ZCP board

KB-800                Keypad board

MB-800                Main board

MO-800                Mother board

PS-800         Switch Mode Power Supply  SP-320-27

Incorporating as optional modular units:

P-9935                USB communication board

P-9935Modbus        RS232 ModBus Communication Card

P-9945RP        Repeater Card

P-9945A        Class A RS485 Network Card

P-9965                Class B CAN Network Card

P-9965A        Class A CAN Network Card

P-9904                Printer Interface Card

Certified with the following options with requirements from EN 54 Part 2:

7.8 Output to fire alarm devices

7.9.1 Output to fire routing equipment

7.9.2 Alarm confirmation input from fire routing equipment

7.10.1 Output type A

7.10.2 Output type B

7.11 Delays to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.13 Alarm counter

8.3 Fault signals from points

9.5 Disablement of each address point

10 Test condition

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

548p/02
IFP2/1

Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment

Incorporating the following units:

MB-220/ F7.820.826                         Main board

SB-220/ F7.820.827                         Switch board

TB-220/ F7.820.828                         Loop interface board

PS-220/ F7.820.829b                         Power supply unit

ZP-220/ F7.820.312d                         Zone indication and intervention board

Incorporating as optional modular units:

P-9930/ F7.820.913a RS-232                 board for configuration

P-9901A                                 Printer module kit

LC200/ F7.820.1125                         Loop board (for loop expansion)

Certified with the following options with requirements from EN 54 part 2:

7.8                                         Output to Fire Alarm Devices

7.10.1                                         Output to automatic Fire Protection Equipment Type A

7.11                                         Delays to outputs

8.3                                         Fault signals from points

9.5                                         Disablement of addressable points

548P/08
IFP2N

Intelligent 2 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment

Incorporating the following units:

MB-220N        Main board

PS-220N        Power management board

OX-220                Terminal board

ZP-220                Zone indication and intervention board

SB-220                Switch board

TB-220N        Loop interface board

LC200                Loop board

PDF-150-27.5         Powered SMPS 100-240V power supply

Incorporating as optional modular units:

P-9930                RS-232 board for configuration

P-9901A         Printer module kit

P-9960A        CAN network card loop type board

P-9940A        RS485 Class A network card

P-9930ModBus        RS232 Modbus interface card

P-9960                CAN Class B network card

Certified with the following options with requirements from EN 54 part 2:

7.8 Output to Fire Alarm Devices

7.10.1 Output to automatic Fire Protection Equipment Type A

7.11 Delays to outputs

8.3 Fault signals from points

9.5 Disablement of addressable points

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

548p/07
IFP1N

Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment

Incorporating the following units:

MB-220N        Main board

PS-220N        Power management board

OX-220                Terminal board

ZP-220                Zone indication and intervention board

SB-220                Switch board

TB-220N        Loop interface board

PDF-150-27.5         Powered SMPS 100-240V power supply

Incorporating as optional modular units:

P-9930                RS-232 board for configuration

P-9901A         Printer module kit

P-9960A        CAN network card loop type board

P-9940A        RS485 Class A network card

P-9930ModBus        RS232 Modbus interface card

P-9960                CAN Class B network card

Certified with the following options with requirements from EN 54 part 2:

7.8 Output to Fire Alarm Devices

7.10.1 Output to automatic Fire Protection Equipment Type A

7.11 Delays to outputs

8.3 Fault signals from points

9.5 Disablement of addressable points

Notes:

  1. Can be converted to 2 loop by adding LC200 Loop board
  2. Scope of approval does not include the operation of the network functionality
  3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13
548p/11
MX704

1 to 4 loop Intelligent Addressable Control and Indicating Equipment

Incorporating the following modules:

7010200004        Mother Board

7020100022            Main Board

7010700017            Loop Board

7010400011            Power Management Board

7010600019            Communication Board

7010400012            Power Wiring Board

PDF-150-27.5    Power Supply Unit

7021300007            Key Board

7020800009            Led Board

7010300010            Regional Display Board

814400002             Printer Module

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm device(s)

7.10.1 Output to fire protection equipment - Type A

7.11 Delays to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.13 Alarm counter

9.5 Disablement of each address point        

10 Test condition

Notes:

1. The scope of the approval does not include the operation of the network functionality

2. The product approval does not constitute compliance with the fire detection and alarm system requirements of EN54-13.