AMPAC Technologies PTY Ltd

7 Ledgar Road
Balcatta
6021
Australia

Tel: +618 (9242) 3333 • Fax: +618 (9242) 3334
Email: askellham@ampac.net • Web: www.ampac.net


Certificate No 966a to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No 966b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1998 + A1: 2002 + A2: 2006




Product Description LPCB
Ref. No.
LoopSense 8281-0105

One loop, 32 Zone analogue addressable control and indicating equipment.

Incorporating the following units:

BRD82MBA        Main Termination Board

BRD82ZICC        Zone Interface & Control Card

PSU2397                Power Supply Unit

ASS82ZICC        Zone Indicator & LCD Assembly (8210)

        

Certificated with the following options with requirements from EN54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.11        Delay to outputs

7.12.1        Dependencies on more than one alarm signal - Type A

7.12.2        Dependencies on more than one alarm signal - Type B

7.12.3        Dependencies on more than one alarm signal - Type C

8.3        Fault signal from points

8.9        Output to fault warning routing equipment

9.5        Disablement of each addressable point

10        Test condition

Note:

1.  This product approval does not constitute compliance with the fire detection and

     alarm systems requirements of EN 54-13.

966a/01
LoopSense 8281-0205

Two loop, 32 Zone analogue addressable control and indicating equipment.

Incorporating the following units:

BRD82MBA        Main Termination Board

BRD82ZICC        Zone Interface & Control Card

PSU2397                 Power Supply Unit

8210-0001        2nd loop activation Key

BRD82LSD        Loop Activation Board

ASS82ZICC        Zone Indicator & LCD Assembly (8210)

        

Certificated with the following options with requirements from EN54-2:

7.8        Output to fire alarm devices

7.9.1        Output to fire alarm routing equipment

7.9.2        Alarm confirmation input from fire alarm routing equipment

7.11        Delay to outputs

7.12.1        Dependencies on more than one alarm signal Type A

7.12.2        Dependencies on more than one alarm signal Type B

7.12.3        Dependencies on more than one alarm signal Type C

8.3        Fault signal from points

8.9        Output to fault warning routing equipment

9.5        Disablement of each addressable point

10        Test condition

Note:

1.  This product approval does not constitute compliance with the fire detection and

     alarm systems requirements of EN 54-13.

966a/02
8681-0108 FireFinder Plus

One loop, 32 Zone analogue addressable control and indicating equipment

Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)

BRD86DLTB4-A FFP Dual loop termination board (8610)

BRD86FPB5-B FFP Front panel board EN54 (8610)

BRD86MBA4-A FFP Main board LCD (8610)

BRD86MCPU4-B FFP Main 64MB CPU card (8610)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

966b/01
8681-0208 FireFinder Plus

Two loop, 32 Zone analogue addressable control and indicating equipment

Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)

BRD86DLTB4-A FFP Dual loop termination board (8610)

BRD86FPB5-B FFP Front panel board EN54 (8610)

BRD86MBA4-A FFP Main board LCD (8610)

BRD86MCPU4-B FFP Main 64MB CPU card (8610)

BRD86SCB3-A FFP Slave CPU card (8610)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

966b/02
8681-0308 FireFinder Plus

Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)

BRD86DLTB4-A FFP Two Dual loop termination boards (8610)

BRD86FPB5-B FFP Front panel board EN54 (8610)

BRD86MBA4-A FFP Main board LCD (8610)

BRD86MCPU4-B FFP Main 64MB CPU card (8610)

BRD86SCB3-A FFP Two Slave CPU cards (8610)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD86DLTB4-A FFP Dual loop termination board (8610)

BRD86SCB3-A FFP Slave CPU cards (8610)

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)

BRD86DLTB4-A FFP Two Dual loop termination boards (8610)

BRD86FPB5-B FFP Front panel board EN54 (8610)

BRD86MBA4-A FFP Main board LCD (8610)

BRD86MCPU4-B FFP Main 64MB CPU card (8610)

BRD86SCB3-A FFP Two Slave CPU cards (8610)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD86DLTB4-A FFP Dual loop termination board (8610)

BRD86SCB3-A FFP Slave CPU cards (8610)

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

966b/03
8681-0408 FireFinder Plus

Four loop, 32 Zone analogue addressable control and indicating equipment

Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)

BRD86DLTB4-A FFP Two Dual loop termination boards (8610)

BRD86FPB5-B FFP Front panel board EN54 (8610)

BRD86MBA4-A FFP Main board LCD (8610)

BRD86MCPU4-B FFP Main 64MB CPU card (8610)

BRD86SCB3-A FFP Three Slave CPU cards (8610)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

PSU1888 Power supply 5A (8610)

Optional Modules:

BRD86DLTB4-A FFP Dual loop termination board (8610)

BRD86SCB3-A FFP Slave CPU cards (8610)

BRD43EZC2-A 8 Zone conventional module (4310)

BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices

7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routine equipment

7.11 Delay to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.12.3 Dependencies on more than one alarm signal - Type C

8.3 Fault signal from points

8.9 Output to fault warning routing equipment

9.5 Disablement of each addressable point

10 Test condition

966b/04

 

 


 