SHIELD FIRE, SAFETY AND SECURITY LTD

Redburn House
2a Tonbridge Road
Romford
Essex
RM3 8QE
United Kingdom

Tel: +44 207 712 1610 • Fax: +44 207 712 1578
Email: shielduk@shieldglobal.com • Web: www.shieldglobal.com


Certificate No 360b-(cl-4) to EN54-2: 1997 + A1: 2002 & EN54-4: 1997 + A1: 2002 + A2: 2006
Certificate No 548p-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No 810a-(cl-3) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006


Control and indicating equipment

Product Description LPCB
Ref. No.
P-A2M

Intelligent 2 Loop, 30 Zone Analogue Addressable Control and Indicating

Equipment

Incorporating the following units:

MB-220/ F7.820.826 Main board

SB-220/ F7.820.827 Switch board

TB-220/ F7.820.828 Loop interface board

PS-220/ F7.820.829b Power supply unit

ZP-220/ F7.820.312d Zone indication and intervention board

LC-A2M/ F7.820.1125 Loop board

Incorporating as optional modular units:

DB-A300/ F7.820.913a RS-232 board for configuration

P-A300P Printer module kit

Certified with the following options with requirements from EN 54 part 2:

7.8 Output to Fire Alarm Devices

7.10.1 Output to automatic Fire Protection Equipment Type A

7.11 Delays to outputs

8.3 Fault signals from points

9.5 Disablement of addressable points

548p/01
P-A8M

Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment

Incorporating the following units:

SB-800                Indication board

LC-A8M        Loop board

PB-800                Power board

ZP-800                ZCP board

KB-800                Keypad board

MB-800                Main board

MO-800                Mother board

PS-800         Switch Mode Power Supply  SP-320-27

Incorporating as optional modular units:

DB-A8M         USB communication board

DB-A8MModbus         RS232 ModBus Communication Card

RB-A8M         Repeater Card

NB-A8MA         Class A RS485 Network Card

NB-CANA8M         Class B CAN Network Card

NB-CANA8MA           Class A CAN Network Card

IC-A8MP         Printer Interface Card

Certified with the following options with requirements from EN54 Part 2:

7.8 Output to fire alarm devices

7.9.1 Output to fire routing equipment

7.9.2 Alarm confirmation input from fire routing equipment

7.10. Output type A

7.10.2 Output type B

7.11 Delays to outputs

7.12.1 Dependencies on more than one alarm signal - Type A

7.12.2 Dependencies on more than one alarm signal - Type B

7.13 Alarm counter

8.3 Fault signals from points

9.5 Disablement of each address point

10 Test condition

Notes:

1. Scope of approval does not include the operation of the network functionality

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13

548p/02
P-C202A

2 Zone Conventional Control and Indicating Equipment

Incorporating the following modules:

FC-102A/ F7.843.399       Membrane

CB-102A/ F2.908.1719     Control board with integrated PSE

DB-102A/ F2.908.1722     Display board

Optional modules:

10104648       Traditional Chinese text variant

CF-102A/ F7.843.421    Membrane

Certified with the following options with requirements from EN 54 Part 2:

7.8       Output to fire alarm devices

7.9.1    Output to fire routing equipment

7.11     Delays to outputs

10        Test condition

548p/03
P-C204A

4 Zone Conventional Control and Indicating Equipment

Incorporating the following modules:

FC-104A/ F7.843.400       Membrane

CB-104A/ F2.908.1718     Control board with integrated PSE

DB-104A/ F2.908.1721     Display board

Certified with the following options with requirements from EN 54 Part 2:

7.8       Output to fire alarm devices

7.9.1    Output to fire routing equipment

7.11     Delays to outputs

10        Test condition

548p/04
P-C208A

8 Zone Conventional Control and Indicating Equipment

Incorporating the following modules:

FC-108A/ F7.843.401       Membrane

CB-108A/ F2.908.1675     Control board with integrated PSE

DB-108A/ F2.908.1720     Display board

Certified with the following options with requirements from EN 54 Part 2:

7.8       Output to fire alarm devices

7.9.1    Output to fire routing equipment

7.11     Delays to outputs

10        Test condition

548p/05
P-C216A

16 Zone Conventional Control and Indicating Equipment

Incorporating the following modules:

FC-116A/ F7.843.402       Membrane

CB-116A/ F2.908.1724     Control board with integrated PSE

DB-116A/ F2.908.1676     Display board

XB-116A/ F7.820.1677     Expansion board

Certified with the following options with requirements from EN 54 Part 2:

7.8       Output to fire alarm devices

7.9.1    Output to fire routing equipment

7.11     Delays to outputs

10        Test condition

548p/06
P-A2M/1

Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment

Incorporating the following units:
MB-220/ F7.820.826                  Main board

SB-220/ F7.820.827                  Switch board

TB-220/ F7.820.828                   Loop interface board

PS-220/ F7.820.829b                Power supply unit

ZP-220/ F7.820.312d                Zone indication and intervention board

Incorporating as optional modular units:
DB-A300/ F7.820.913a             RS-232 board for configuration

P-A300P Printer module kit

LC-A2M/ F7.820.1125 Loop board (for loop expansion)

Certified with the following options with requirements from EN 54 part 2:
7.8                                       Output to Fire Alarm Devices

7.10.1                                  Output to automatic Fire Protection Equipment Type A

7.11                                     Delays to outputs

8.3                                       Fault signals from points

9.5                                       Disablement of addressable points

Note: Can be extended to 2-loop panel by adding LC-A2M

Incorporating as optional modular units:

Incorporating as optional modular units:

DB-A300/ F7.820.913a RS-232 board for configuration

P-A300P Printer module kit

LC-A2M/ F7.820.1125 Loop board (for loop expansion)

548p/08
Trident

2 to 8 Loop Analogue Addressable Control and Indicating Equipment

2 to 16 Loop Analogue Addressable Control and Indicating Equipment

Incorporating the following units:

TEN-9021         LCD Main Processor Board

TEN-9022        Main Back Board

TEN-9023        Trident Network, Ethernet & IFAM Interface Module

TEN-9058         Dual loop Module

TEN-9069        System Board A module

TEN-9070         System Board B Module

TEN-9071         Zone LED Board

TEN-9087        Trident Vision Unit

TEN-9068             Trident Thermal Printer Assembly

TEN-9606         5.25 Amp Power Supply Unit

Incorporating the following optional modules:

TEN-9810         10.25 Amp Power Supply Unit

TEN-9072        16 Channel I/O card  

TEN-9091        8w Relay card

TEN-9092         8w conventional zone card

TEN-9088        Media gateway card

TEN-9093        4w sounder card

TEN-9086        4 slot expansion board (used for extension for the optional I/O boards)

Certified with the following Options with requirements from EN 54-2:1997

7.8         Output to fire alarm device(s)

7.9.1         Output to fire alarm routing equipment

7.9.2         Alarm confirmation input from fire alarm routing equipment

7.10.3         Output to type C

7.10.4   Fault monitoring of fire protection equipment

7.11         Delay to outputs

7.12.1   Dependencies on more than one alarm signal - Type A

7.12.2   Dependencies on more than one alarm signal - Type B

7.12.3   Dependencies on more than one alarm signal - Type C

7.13         Alarm counter

8.3         Fault signals from points

8.9         Output to fault warning routing equipment

9.5         Disablement of addressable points

10         Test condition

Notes:

1. Scope of certification does not include the operation of the network functionality.

2. This certificate does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

3. The Taktis CIE is certified with the M5 & M6 shallow enclosure and D5 & D6 deep enclosure.

360b/01
P-A300N-2

Intelligent 2 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment

Incorporating the following units:

MB-220N        Main board

PS-220N        Power management board

OX-220                Terminal board

ZP-220          Zone indication and intervention board

SB-220                Switch board

TB-220N        Loop interface board

LC200                Loop board

PDF-150-27.5         Powered SMPS 100-240V power supply

Incorporating as optional modular units:

DB-A300        RS-232 board for configuration

P-A300P         Printer module kit

NB-CAN300A         CAN network card loop type board

DB-A300ModBus RS232 Modbus interface card

NB-A300N         Class A RS485 network card

NB-CAN300         Class B CAN network card

Certified with the following options with requirements from EN54 part 2:

7.8 Output to Fire Alarm Devices

7.10.1 Output to automatic Fire Protection Equipment Type A

7.11 Delays to outputs

8.3 Fault signals from points

9.5 Disablement of addressable points

Notes:

  1. Scope of approval does not include the operation of the network functionality
  2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13
548p/07
P-A300N-1

Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment

Incorporating the following units:

MB-220N         Main board

PS-220N         Power management board

OX-220                 Terminal board

ZP-220                 Zone indication and intervention board

SB-220                 Switch board

TB-220N         Loop interface board

PDF-150-27.5          Powered SMPS 100-240V power supply

Incorporating as optional modular units:

DB-A300        RS-232 board for configuration

P-A300P         Printer module kit

NB-CAN300A         CAN network card loop type board

DB-A300ModBus RS232 Modbus interface card

NB-A300N         Class A RS485 network card

NB-CAN300         Class B CAN network card

Certified with the following options with requirements from EN54 part 2:

7.8 Output to Fire Alarm Devices

7.10.1 Output to automatic Fire Protection Equipment Type A

7.11 Delays to outputs

8.3 Fault signals from points

9.5 Disablement of addressable points

Notes:

  1. Can be converted to 2 loop by adding LC200 Loop board
  2. Scope of approval does not include the operation of the network functionality
  3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13
548p/11
NS-EN2 / NS-EN4

2 Zone Conventional Control and Indicating Equipment

Incorporating as modular units:

TPC A01-S2         Eclipse two zone main PCB applicable on 2 zone CIE only

TPC A02         Eclipse LED display PCB

PSM1.5-24         Power supply 1.5A rated

Certified with the following options with requirements from EN 54 Part 2:

7.8         Output to fire alarm devices

7.12.1         Dependency on more than one alarm signal type A

10         Test condition

4 Zone Conventional Control and Indicating Equipment

Incorporating as modular units:

TPC A01- S4         Eclipse four zone main PCB applicable on 4 zone CIE only

TPC A02         Eclipse LED display PCB

PSM1.5-24         Power supply 1.5A rated

Certified with the following options with requirements from EN 54 Part 2:

7.8         Output to fire alarm devices

7.12.1         Dependency on more than one alarm signal type A

10         Test condition

Note:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

810a/09
NS-EN8

8 Zone Conventional Control and Indicating Equipment

Incorporating as modular units:

TPCA01-X4         XLEN 4 Zone Main PCB

TPCA03         XLEN Display Board

TPCA04-H          XLEN High Spec 4 Zone Extension Board

PSM3.0-24         Power Supply

Incorporating as optional module:

NS-EN-NCB         Network Communication Board

Certified with the following options with requirements from EN 54 Part 2:

7.8         Output to fire alarm devices

7.11         Delays to outputs

7.12.1         Dependency on more than one alarm signal type A

7.12.2         Dependency on more than one alarm signal type B

7.12.3         Dependency on more than one alarm signal type C

10         Test condition

Note:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

810a/10
NS-EN12

12 Zone Conventional Control and Indicating Equipment

Incorporating as modular units:

TPCA01-X4         XLEN 4 Zone Main PCB

TPCA03         XLEN Display Board

TPCA04-S         XLEN Standard 4 Zone Extension Board

TPCA04-H         XLEN High Spec 4 Zone Extension Board

PSM3.0-24         Power Supply

Incorporating as optional module:

NS-EN-NCB         Network Communication Board

Certified with the following options with requirements from EN 54 Part 2:

7.8         Output to fire alarm devices

7.11         Delays to outputs

7.12.1         Dependency on more than one alarm signal type A

7.12.2         Dependency on more than one alarm signal type B

7.12.3         Dependency on more than one alarm signal type C

10         Test condition

Note:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

810a/11
NS-EN16

16 Zone Conventional Control and Indicating Equipment

Incorporating as modular units:

TPCA10         32 Zone LED display PCB

TPCA11-16         16 Zone Main PCB

TPCA12         Power supply PCB

and as optional modules

TPCR01         Relay PCB

TPCR03         Isolate Switch PCB

TPCA09         Sounder Card PCB

TPCA08         Output Card PCB

NS-EN-NCB         Network Communication Board

Certified with the following options with requirements from EN 54 Part 2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.11         Delays to outputs

7.12.1         Dependency on more than one alarm signal type A

7.12.2         Dependency on more than one alarm signal type B

7.12.3         Dependency on more than one alarm signal type C

10         Test condition

Note:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

810a/12
NS-EN24

24 Zone Conventional Control and Indicating Equipment

Incorporating as modular units:

TPCA10         32 Zone LED display PCB

TPCA11-24         24 Zone Main PCB

TPCA12         Power supply PCB

and as optional modules

TPCR01         Relay PCB

TPCR03         Isolate Switch PCB

TPCA09         Sounder Card PCB

TPCA08         Output Card PCB

NS-EN-NCB         Network Communication Board

Certified with the following options with requirements from EN 54 Part 2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.11         Delays to outputs

7.12.1         Dependency on more than one alarm signal type A

7.12.2         Dependency on more than one alarm signal type B

7.12.3         Dependency on more than one alarm signal type C

10         Test condition

Note:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

810a/13
NS-EN32

32 Zone Conventional Control and Indicating Equipment

Incorporating as modular units:

TPCA10         32 Zone LED display PCB

TPCA11-32         32 Zone Main PCB

TPCA12         Power supply PCB

and as optional modules

TPCR01         Relay PCB

TPCR03         Isolate Switch PCB

TPCA09         Sounder Card PCB

TPCA08         Output Card PCB

NS-EN-NCB         Network Communication Board

Certified with the following options with requirements from EN 54 Part 2:

7.8         Output to fire alarm devices

7.9.1         Output to fire alarm routing equipment

7.11         Delays to outputs

7.12.1         Dependency on more than one alarm signal type A

7.12.2         Dependency on more than one alarm signal type B

7.12.3         Dependency on more than one alarm signal type C

10         Test condition

Note:

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

810a/14

 

 


 